{"id":"https://openalex.org/W2071143001","doi":"https://doi.org/10.1109/ssd.2012.6198119","title":"HVDC SuperGrids with modular multilevel converters &amp;#x2014; The power transmission backbone of the future","display_name":"HVDC SuperGrids with modular multilevel converters &amp;#x2014; The power transmission backbone of the future","publication_year":2012,"publication_date":"2012-03-01","ids":{"openalex":"https://openalex.org/W2071143001","doi":"https://doi.org/10.1109/ssd.2012.6198119","mag":"2071143001"},"language":"en","primary_location":{"id":"doi:10.1109/ssd.2012.6198119","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ssd.2012.6198119","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Multi-Conference on Systems, Sygnals &amp; Devices","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005156207","display_name":"Noman Ahmed","orcid":null},"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":true,"raw_author_name":"Noman Ahmed","raw_affiliation_strings":["Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden"],"affiliations":[{"raw_affiliation_string":"Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden","institution_ids":["https://openalex.org/I86987016"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036183004","display_name":"Staffan Norrga","orcid":"https://orcid.org/0000-0002-8565-4753"},"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Staffan Norrga","raw_affiliation_strings":["Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden"],"affiliations":[{"raw_affiliation_string":"Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden","institution_ids":["https://openalex.org/I86987016"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034709081","display_name":"Hans\u2010Peter Nee","orcid":"https://orcid.org/0000-0002-1755-1365"},"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Hans-Peter Nee","raw_affiliation_strings":["Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden"],"affiliations":[{"raw_affiliation_string":"Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden","institution_ids":["https://openalex.org/I86987016"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057058071","display_name":"Arif Haider","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Arif Haider","raw_affiliation_strings":["Etteplan Industry AB, Vasteras, Sweden","Etteplan Industry AB, V\u00e4ster\u00e5s, Sweden"],"affiliations":[{"raw_affiliation_string":"Etteplan Industry AB, Vasteras, Sweden","institution_ids":[]},{"raw_affiliation_string":"Etteplan Industry AB, V\u00e4ster\u00e5s, Sweden","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018842792","display_name":"Dirk Van Hertem","orcid":"https://orcid.org/0000-0001-5461-8891"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]},{"id":"https://openalex.org/I89206478","display_name":"Engie (Belgium)","ror":"https://ror.org/00c97z041","country_code":"BE","type":"company","lineage":["https://openalex.org/I4210124897","https://openalex.org/I89206478"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Dirk Van Hertem","raw_affiliation_strings":["ESAT/ELECTA, KU Leuven, Belgium","ESAT/ELECTA, K.U. Leuven, Belgium"],"affiliations":[{"raw_affiliation_string":"ESAT/ELECTA, KU Leuven, Belgium","institution_ids":["https://openalex.org/I89206478","https://openalex.org/I99464096"]},{"raw_affiliation_string":"ESAT/ELECTA, K.U. Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101829223","display_name":"Lidong Zhang","orcid":"https://orcid.org/0009-0005-0221-4410"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Lidong Zhang","raw_affiliation_strings":["ABB, Ludvika, Sweden"],"affiliations":[{"raw_affiliation_string":"ABB, Ludvika, Sweden","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083571879","display_name":"Lennart Harnefors","orcid":"https://orcid.org/0000-0002-3107-7073"},"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Lennart Harnefors","raw_affiliation_strings":["Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden","ABB, Ludvika, Sweden"],"affiliations":[{"raw_affiliation_string":"Electrical Energy Conversion (E2C), KTH Royal Institute of Technology, Stockholm, Sweden","institution_ids":["https://openalex.org/I86987016"]},{"raw_affiliation_string":"ABB, Ludvika, Sweden","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5005156207"],"corresponding_institution_ids":["https://openalex.org/I86987016"],"apc_list":null,"apc_paid":null,"fwci":8.3471,"has_fulltext":false,"cited_by_count":79,"citation_normalized_percentile":{"value":0.97991643,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9498999714851379,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9212999939918518,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.7542871236801147},{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.7374436855316162},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.6954192519187927},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6354678869247437},{"id":"https://openalex.org/keywords/overhead","display_name":"Overhead (engineering)","score":0.6109880805015564},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.6043241024017334},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5362602472305298},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.531478226184845},{"id":"https://openalex.org/keywords/power-transmission","display_name":"Power transmission","score":0.5007917881011963},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4726659059524536},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4650458097457886},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.4474141001701355},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4414997100830078},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3853936195373535},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3708871603012085},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3573504686355591},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.1538519561290741},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.12302851676940918},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08213719725608826}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.7542871236801147},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.7374436855316162},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.6954192519187927},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6354678869247437},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.6109880805015564},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.6043241024017334},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5362602472305298},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.531478226184845},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.5007917881011963},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4726659059524536},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4650458097457886},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.4474141001701355},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4414997100830078},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3853936195373535},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3708871603012085},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3573504686355591},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.1538519561290741},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.12302851676940918},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08213719725608826},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ssd.2012.6198119","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ssd.2012.6198119","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Multi-Conference on Systems, Sygnals &amp; Devices","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8700000047683716,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W29773986","https://openalex.org/W287890302","https://openalex.org/W1915388693","https://openalex.org/W1957077884","https://openalex.org/W2034978548","https://openalex.org/W2055905802","https://openalex.org/W2066077687","https://openalex.org/W2102817687","https://openalex.org/W2111134324","https://openalex.org/W2111311558","https://openalex.org/W2135750667","https://openalex.org/W2141459684","https://openalex.org/W2142672517","https://openalex.org/W2156232631","https://openalex.org/W2159008479","https://openalex.org/W2160339726","https://openalex.org/W2160830391","https://openalex.org/W2538824575","https://openalex.org/W2549788447","https://openalex.org/W2921733795","https://openalex.org/W6729709298"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W3215534511","https://openalex.org/W2377988082","https://openalex.org/W4309066160","https://openalex.org/W2902302001","https://openalex.org/W199455138","https://openalex.org/W2535590592","https://openalex.org/W2597335086","https://openalex.org/W4360996207","https://openalex.org/W1992558323"],"abstract_inverted_index":{"In":[0],"order":[1],"to":[2,19,40,83,109],"transmit":[3],"massive":[4],"amounts":[5],"of":[6,24,63,120,124],"power":[7,12,44],"generated":[8],"by":[9],"remotely":[10],"located":[11],"plants,":[13],"especially":[14],"offshore":[15],"wind":[16],"farms,":[17],"and":[18,77,94,106,148],"balance":[20],"the":[21,28,46,61,64,107,134,141,145],"intermittent":[22],"nature":[23],"renewable":[25],"energy":[26],"sources,":[27],"need":[29],"for":[30,50,97,103,144],"a":[31,52,55,86,104,131],"stronger":[32],"high":[33],"voltage":[34],"transmission":[35,45],"grid":[36,53,66,147],"is":[37,54,67,79,126],"anticipated.":[38],"Due":[39],"limitations":[41],"in":[42],"ac":[43],"most":[47],"likable":[48],"choice":[49,135],"such":[51,85],"high-voltage":[56],"dc":[57,87,146],"(HVDC)":[58],"grid.":[59,88],"However,":[60],"concept":[62],"HVDC":[65,99],"still":[68],"under":[69],"active":[70],"development":[71],"as":[72,128,130],"different":[73,121],"technical":[74,95],"challenges":[75,96],"exist,":[76],"it":[78],"not":[80],"yet":[81],"possible":[82],"construct":[84],"This":[89],"paper":[90],"deals":[91],"with":[92],"prospects":[93],"future":[98],"SuperGrids.":[100],"Different":[101],"topologies":[102],"SuperGrid":[105],"possibility":[108],"use":[110],"modular":[111],"multilevel":[112],"converters":[113],"(M2Cs)":[114],"are":[115],"presented.":[116],"A":[117],"comprehensive":[118],"overview":[119],"submodule":[122],"implementations":[123],"M2C":[125],"given":[127],"well":[129],"discussion":[132],"on":[133],"between":[136],"cables":[137],"or":[138],"overhead":[139],"lines,":[140],"protection":[142],"system":[143],"dc-side":[149],"resonance":[150],"issues.":[151]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":7},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":12},{"year":2015,"cited_by_count":9},{"year":2014,"cited_by_count":13},{"year":2013,"cited_by_count":7},{"year":2012,"cited_by_count":5}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
