{"id":"https://openalex.org/W2081522015","doi":"https://doi.org/10.1109/smartgridcomm.2012.6486036","title":"Robust distributed energy management for microgrids with renewables","display_name":"Robust distributed energy management for microgrids with renewables","publication_year":2012,"publication_date":"2012-11-01","ids":{"openalex":"https://openalex.org/W2081522015","doi":"https://doi.org/10.1109/smartgridcomm.2012.6486036","mag":"2081522015"},"language":"en","primary_location":{"id":"doi:10.1109/smartgridcomm.2012.6486036","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2012.6486036","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100433414","display_name":"Yu Zhang","orcid":"https://orcid.org/0000-0001-7889-2676"},"institutions":[{"id":"https://openalex.org/I130238516","display_name":"University of Minnesota","ror":"https://ror.org/017zqws13","country_code":"US","type":"education","lineage":["https://openalex.org/I130238516"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Yu Zhang","raw_affiliation_strings":["Department of ECE and DTC, University of Minnesota, Minneapolis, USA","Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA"],"affiliations":[{"raw_affiliation_string":"Department of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]},{"raw_affiliation_string":"Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022494957","display_name":"Nikolaos Gatsis","orcid":"https://orcid.org/0000-0002-5238-649X"},"institutions":[{"id":"https://openalex.org/I130238516","display_name":"University of Minnesota","ror":"https://ror.org/017zqws13","country_code":"US","type":"education","lineage":["https://openalex.org/I130238516"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Nikolaos Gatsis","raw_affiliation_strings":["Department of ECE and DTC, University of Minnesota, Minneapolis, USA","Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA"],"affiliations":[{"raw_affiliation_string":"Department of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]},{"raw_affiliation_string":"Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5026758314","display_name":"Georgios B. Giannakis","orcid":"https://orcid.org/0000-0002-0196-0260"},"institutions":[{"id":"https://openalex.org/I130238516","display_name":"University of Minnesota","ror":"https://ror.org/017zqws13","country_code":"US","type":"education","lineage":["https://openalex.org/I130238516"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Georgios B. Giannakis","raw_affiliation_strings":["Department of ECE and DTC, University of Minnesota, Minneapolis, USA","Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA"],"affiliations":[{"raw_affiliation_string":"Department of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]},{"raw_affiliation_string":"Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100433414"],"corresponding_institution_ids":["https://openalex.org/I130238516"],"apc_list":null,"apc_paid":null,"fwci":7.3716,"has_fulltext":false,"cited_by_count":34,"citation_normalized_percentile":{"value":0.96908383,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"510","last_page":"515"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8265834450721741},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.7464196085929871},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.7306107878684998},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6272870302200317},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.6046774983406067},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.5169936418533325},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.49855923652648926},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.4972973167896271},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4940243363380432},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.4741731882095337},{"id":"https://openalex.org/keywords/distributed-power","display_name":"Distributed power","score":0.42723917961120605},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.3452990651130676},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21100834012031555},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.18665239214897156},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.1481243073940277},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1288025975227356}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8265834450721741},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.7464196085929871},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.7306107878684998},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6272870302200317},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.6046774983406067},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.5169936418533325},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.49855923652648926},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4972973167896271},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4940243363380432},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.4741731882095337},{"id":"https://openalex.org/C36877392","wikidata":"https://www.wikidata.org/wiki/Q1229571","display_name":"Distributed power","level":3,"score":0.42723917961120605},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.3452990651130676},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21100834012031555},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.18665239214897156},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.1481243073940277},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1288025975227356},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/smartgridcomm.2012.6486036","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2012.6486036","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8899999856948853}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W106711868","https://openalex.org/W633277346","https://openalex.org/W1890570698","https://openalex.org/W1963529497","https://openalex.org/W1966925146","https://openalex.org/W1975833767","https://openalex.org/W1976742521","https://openalex.org/W1991716092","https://openalex.org/W1994293339","https://openalex.org/W1999688255","https://openalex.org/W2018059892","https://openalex.org/W2035121397","https://openalex.org/W2067108585","https://openalex.org/W2067311513","https://openalex.org/W2075141080","https://openalex.org/W2137716965","https://openalex.org/W2156604062","https://openalex.org/W2160058123","https://openalex.org/W2296319761","https://openalex.org/W2787523326","https://openalex.org/W4234534407","https://openalex.org/W4250589301"],"related_works":["https://openalex.org/W2355150740","https://openalex.org/W2906602677","https://openalex.org/W3090776330","https://openalex.org/W2051053503","https://openalex.org/W3112588909","https://openalex.org/W1993958856","https://openalex.org/W2169268775","https://openalex.org/W2347673489","https://openalex.org/W4295036313","https://openalex.org/W1570369983"],"abstract_inverted_index":{"Due":[0],"to":[1,8,92,133],"the":[2,42,52,69,76,80,86,94,111,116,119,135,138],"low":[3],"communication":[4],"overhead":[5],"and":[6,37],"robustness":[7],"failures,":[9],"distributed":[10,25,127],"energy":[11,60,72,77],"management":[12,39],"is":[13,45,83,123],"of":[14,54,58,137],"paramount":[15],"importance":[16],"in":[17,21,41,47,113,125],"smart":[18],"grids,":[19],"especially":[20],"microgrids,":[22],"which":[23,98],"feature":[24],"generation":[26],"(DG).":[27],"Distributed":[28],"economic":[29],"dispatch":[30],"for":[31],"a":[32,63,126],"microgrid":[33,95],"with":[34,79],"renewable":[35,59,71],"penetration":[36],"demand-side":[38],"operating":[40],"grid-connected":[43],"mode":[44],"considered":[46],"this":[48],"paper.":[49],"To":[50],"address":[51],"challenge":[53],"intrinsically":[55],"stochastic":[56],"availability":[57],"sources":[61],"(RES),":[62],"novel":[64,139],"power":[65],"scheduling":[66],"approach":[67],"involving":[68],"actual":[70],"as":[73,75,103,105],"well":[74,104],"traded":[78],"main":[81],"grid":[82],"introduced,":[84],"effecting":[85],"supply-demand":[87],"balance.":[88],"Its":[89],"optimality":[90],"amounts":[91],"minimizing":[93],"net":[96],"cost,":[97],"includes":[99],"conventional":[100],"DG":[101],"cost":[102,108],"worst-case":[106],"transaction":[107],"stemming":[109],"from":[110],"uncertainty":[112],"RES.":[114],"Leveraging":[115],"dual":[117],"decomposition,":[118],"optimization":[120],"problem":[121],"formulated":[122],"solved":[124],"fashion.":[128],"Numerical":[129],"results":[130],"are":[131],"reported":[132],"corroborate":[134],"effectiveness":[136],"approach.":[140]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":4},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
