{"id":"https://openalex.org/W4382204840","doi":"https://doi.org/10.1109/saci58269.2023.10158540","title":"Damage Locating of 6-500 kV Cables in Polymer Pipes","display_name":"Damage Locating of 6-500 kV Cables in Polymer Pipes","publication_year":2023,"publication_date":"2023-05-23","ids":{"openalex":"https://openalex.org/W4382204840","doi":"https://doi.org/10.1109/saci58269.2023.10158540"},"language":"en","primary_location":{"id":"doi:10.1109/saci58269.2023.10158540","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/saci58269.2023.10158540","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 17th International Symposium on Applied Computational Intelligence and Informatics (SACI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082813429","display_name":"\u041c. \u041e. Dmitriev","orcid":"https://orcid.org/0000-0002-6211-4164"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"M. Dmitriev","raw_affiliation_strings":["LLP &#x201C;PolymerEnergy&#x201D;,Technical department,Astana,Qazaqstan"],"affiliations":[{"raw_affiliation_string":"LLP &#x201C;PolymerEnergy&#x201D;,Technical department,Astana,Qazaqstan","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036673393","display_name":"Gy\u00f6rgy Morva","orcid":null},"institutions":[{"id":"https://openalex.org/I2801419141","display_name":"Buda Health Center","ror":"https://ror.org/00yx04352","country_code":"HU","type":"healthcare","lineage":["https://openalex.org/I2801419141"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"Gy\u00f6rgy Morva","raw_affiliation_strings":["&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary"],"affiliations":[{"raw_affiliation_string":"&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary","institution_ids":["https://openalex.org/I2801419141"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027183998","display_name":"P Kadar","orcid":"https://orcid.org/0000-0001-5828-6417"},"institutions":[{"id":"https://openalex.org/I2801419141","display_name":"Buda Health Center","ror":"https://ror.org/00yx04352","country_code":"HU","type":"healthcare","lineage":["https://openalex.org/I2801419141"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"P\u00e9ter K\u00e1d\u00e1r","raw_affiliation_strings":["&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary"],"affiliations":[{"raw_affiliation_string":"&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary","institution_ids":["https://openalex.org/I2801419141"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5082813429"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.05115275,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"17","issue":null,"first_page":"000261","last_page":"000266"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9753999710083008,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9753999710083008,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9473999738693237,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9351999759674072,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/focus","display_name":"Focus (optics)","score":0.6926805377006531},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5726665258407593},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4605743885040283},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.407323956489563},{"id":"https://openalex.org/keywords/forensic-engineering","display_name":"Forensic engineering","score":0.3526042103767395},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3348502516746521},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.3243829607963562},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.2126622200012207},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07131117582321167},{"id":"https://openalex.org/keywords/seismology","display_name":"Seismology","score":0.057827383279800415}],"concepts":[{"id":"https://openalex.org/C192209626","wikidata":"https://www.wikidata.org/wiki/Q190909","display_name":"Focus (optics)","level":2,"score":0.6926805377006531},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5726665258407593},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4605743885040283},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.407323956489563},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.3526042103767395},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3348502516746521},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.3243829607963562},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.2126622200012207},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07131117582321167},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.057827383279800415},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/saci58269.2023.10158540","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/saci58269.2023.10158540","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 17th International Symposium on Applied Computational Intelligence and Informatics (SACI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2794013471"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W2751656612","https://openalex.org/W1546415126","https://openalex.org/W2015192756","https://openalex.org/W1584420410","https://openalex.org/W2367451036","https://openalex.org/W2120815133","https://openalex.org/W2351837897","https://openalex.org/W2389324249","https://openalex.org/W2053618284"],"abstract_inverted_index":{"In":[0,10],"this":[1],"paper":[2],"is":[3,19],"introduced":[4],"a":[5,35],"cable":[6,15],"damage":[7],"locating":[8],"methodology.":[9],"the":[11,14,21,28],"recent":[12],"years":[13],"fault":[16],"location":[17],"topic":[18],"in":[20],"focus.":[22],"We":[23],"give":[24],"an":[25],"overview":[26],"about":[27],"widely":[29],"used":[30],"methods":[31],"then":[32],"we":[33],"recommend":[34],"new,":[36],"more":[37],"accurate":[38],"method":[39],"based":[40],"on":[41],"induction.":[42]},"counts_by_year":[],"updated_date":"2025-12-21T01:58:51.020947","created_date":"2025-10-10T00:00:00"}
