{"id":"https://openalex.org/W1992840562","doi":"https://doi.org/10.1109/pscc.2014.7038392","title":"Adjusting third zone distance protection to avoid voltage collapse","display_name":"Adjusting third zone distance protection to avoid voltage collapse","publication_year":2014,"publication_date":"2014-08-01","ids":{"openalex":"https://openalex.org/W1992840562","doi":"https://doi.org/10.1109/pscc.2014.7038392","mag":"1992840562"},"language":"en","primary_location":{"id":"doi:10.1109/pscc.2014.7038392","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pscc.2014.7038392","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 Power Systems Computation Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022509790","display_name":"Vassilis C. Nikolaidis","orcid":"https://orcid.org/0000-0001-8616-2067"},"institutions":[{"id":"https://openalex.org/I147962203","display_name":"Democritus University of Thrace","ror":"https://ror.org/03bfqnx40","country_code":"GR","type":"education","lineage":["https://openalex.org/I147962203"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"V. C. Nikolaidis","raw_affiliation_strings":["Democritus University of Thrace (DUTH), Xanthi, Greece","Democritus University of Thrace (DUTh), Xanthi, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Democritus University of Thrace (DUTH), Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]},{"raw_affiliation_string":"Democritus University of Thrace (DUTh), Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014974367","display_name":"Nikolaos Savvopoulos","orcid":"https://orcid.org/0000-0001-7994-4888"},"institutions":[{"id":"https://openalex.org/I147962203","display_name":"Democritus University of Thrace","ror":"https://ror.org/03bfqnx40","country_code":"GR","type":"education","lineage":["https://openalex.org/I147962203"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"N. Savvopoulos","raw_affiliation_strings":["Democritus University of Thrace (DUTH), Xanthi, Greece","Democritus University of Thrace (DUTh), Xanthi, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Democritus University of Thrace (DUTH), Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]},{"raw_affiliation_string":"Democritus University of Thrace (DUTh), Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054569964","display_name":"A.S. Safigianni","orcid":null},"institutions":[{"id":"https://openalex.org/I147962203","display_name":"Democritus University of Thrace","ror":"https://ror.org/03bfqnx40","country_code":"GR","type":"education","lineage":["https://openalex.org/I147962203"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"A. S. Safigianni","raw_affiliation_strings":["Democritus University of Thrace (DUTH), Xanthi, Greece","Democritus University of Thrace (DUTh), Xanthi, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Democritus University of Thrace (DUTH), Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]},{"raw_affiliation_string":"Democritus University of Thrace (DUTh), Xanthi, Greece","institution_ids":["https://openalex.org/I147962203"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032174634","display_name":"Costas Vournas","orcid":"https://orcid.org/0000-0001-5036-5356"},"institutions":[{"id":"https://openalex.org/I174458059","display_name":"National Technical University of Athens","ror":"https://ror.org/03cx6bg69","country_code":"GR","type":"education","lineage":["https://openalex.org/I174458059"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"C. D. Vournas","raw_affiliation_strings":["National Technical University of Athens (NTUA), Athens, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Technical University of Athens (NTUA), Athens, Greece","institution_ids":["https://openalex.org/I174458059"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.8208,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.76818367,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/tripping","display_name":"Tripping","score":0.9050496816635132},{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.7844539880752563},{"id":"https://openalex.org/keywords/load-shedding","display_name":"Load Shedding","score":0.7510029673576355},{"id":"https://openalex.org/keywords/blackout","display_name":"Blackout","score":0.6075544953346252},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.5603525042533875},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.523653507232666},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4961777627468109},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4780229330062866},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.47790202498435974},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4653756320476532},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4560839831829071},{"id":"https://openalex.org/keywords/instability","display_name":"Instability","score":0.45361119508743286},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4481722414493561},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.40618714690208435},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.37341761589050293},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3701589107513428},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.29297247529029846},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.10665786266326904},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.07172107696533203},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.06981000304222107}],"concepts":[{"id":"https://openalex.org/C2779733308","wikidata":"https://www.wikidata.org/wiki/Q17146464","display_name":"Tripping","level":3,"score":0.9050496816635132},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.7844539880752563},{"id":"https://openalex.org/C2779777743","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Load Shedding","level":4,"score":0.7510029673576355},{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.6075544953346252},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.5603525042533875},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.523653507232666},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4961777627468109},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4780229330062866},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.47790202498435974},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4653756320476532},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4560839831829071},{"id":"https://openalex.org/C207821765","wikidata":"https://www.wikidata.org/wiki/Q405372","display_name":"Instability","level":2,"score":0.45361119508743286},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4481722414493561},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.40618714690208435},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.37341761589050293},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3701589107513428},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.29297247529029846},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.10665786266326904},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.07172107696533203},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.06981000304222107},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pscc.2014.7038392","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pscc.2014.7038392","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 Power Systems Computation Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1489718105","https://openalex.org/W1538056276","https://openalex.org/W1843615650","https://openalex.org/W1982535530","https://openalex.org/W1998842209","https://openalex.org/W2019220013","https://openalex.org/W2107667271","https://openalex.org/W2112949599","https://openalex.org/W2115131727","https://openalex.org/W2124077418","https://openalex.org/W2126180700","https://openalex.org/W2133487860","https://openalex.org/W2140780085","https://openalex.org/W2151118837","https://openalex.org/W2152280277","https://openalex.org/W2154096790","https://openalex.org/W2539680737","https://openalex.org/W4212821273","https://openalex.org/W4245685670","https://openalex.org/W4252329382","https://openalex.org/W6678875748","https://openalex.org/W6728917591"],"related_works":["https://openalex.org/W4206702420","https://openalex.org/W2981774805","https://openalex.org/W2085484687","https://openalex.org/W2066910221","https://openalex.org/W1971178525","https://openalex.org/W2162681100","https://openalex.org/W2224170881","https://openalex.org/W2802070362","https://openalex.org/W2766276228","https://openalex.org/W2548442521"],"abstract_inverted_index":{"Undesirable":[0],"distance":[1,47,55],"relay":[2],"operations":[3],"are":[4],"possible":[5],"to":[6,15,42,91,98],"be":[7,43,92],"initiated":[8,44],"under":[9],"heavy":[10],"stressed":[11],"system":[12,27,32,100],"conditions":[13],"leading":[14],"voltage":[16,68],"instability.":[17],"This":[18,50],"can":[19],"result":[20],"in":[21,24,96],"cascaded":[22],"outages":[23],"the":[25,65,81],"transmission":[26],"that":[28,58],"may":[29],"cause":[30],"severe":[31],"deterioration.":[33],"A":[34],"number":[35],"of":[36,67],"recent":[37],"blackouts":[38],"have":[39],"been":[40],"reported":[41],"from":[45],"undesired":[46],"protection":[48],"operations.":[49],"paper":[51],"proposes":[52],"an":[53],"adaptive":[54],"relaying":[56,72],"scheme":[57,73],"avoids":[59],"undesirable":[60],"third":[61],"zone":[62],"tripping":[63],"during":[64],"evolution":[66],"instability":[69],"phenomena.":[70],"The":[71],"is":[74],"based":[75],"on":[76],"local":[77],"measurements":[78],"and":[79],"provides":[80],"necessary":[82],"time":[83],"for":[84],"other":[85],"emergency":[86],"controls":[87],"like":[88],"undervoltage":[89],"load-shedding":[90],"applied,":[93],"if":[94],"needed,":[95],"order":[97],"mitigate":[99],"collapse.":[101]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
