{"id":"https://openalex.org/W2015052331","doi":"https://doi.org/10.1109/msn.2011.34","title":"Energy-Efficient Data Gathering in High-Voltage Transmission Line Monitoring System","display_name":"Energy-Efficient Data Gathering in High-Voltage Transmission Line Monitoring System","publication_year":2011,"publication_date":"2011-12-01","ids":{"openalex":"https://openalex.org/W2015052331","doi":"https://doi.org/10.1109/msn.2011.34","mag":"2015052331"},"language":"en","primary_location":{"id":"doi:10.1109/msn.2011.34","is_oa":false,"landing_page_url":"https://doi.org/10.1109/msn.2011.34","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Seventh International Conference on Mobile Ad-hoc and Sensor Networks","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103211436","display_name":"Zenghua Zhao","orcid":"https://orcid.org/0000-0001-8850-2870"},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zenghua Zhao","raw_affiliation_strings":["School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","School of Computer Science and Technology,Tianjin University,Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"School of Computer Science and Technology,Tianjin University,Tianjin, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056103928","display_name":"Yanchao Mao","orcid":"https://orcid.org/0000-0002-3436-633X"},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yanchao Mao","raw_affiliation_strings":["School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","School of Computer Science and Technology,Tianjin University,Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"School of Computer Science and Technology,Tianjin University,Tianjin, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003252390","display_name":"Gaotao Shi","orcid":null},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Gaotao Shi","raw_affiliation_strings":["School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","School of Computer Science and Technology,Tianjin University,Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"School of Computer Science and Technology,Tianjin University,Tianjin, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011938607","display_name":"Zhibin Dou","orcid":null},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhibin Dou","raw_affiliation_strings":["School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","School of Computer Science and Technology,Tianjin University,Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"School of Computer Science and Technology,Tianjin University,Tianjin, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109304114","display_name":"Yantai Shu","orcid":null},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yantai Shu","raw_affiliation_strings":["School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","School of Computer Science and Technology,Tianjin University,Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Computer Science and Technology, Tianjin University, TJU, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"School of Computer Science and Technology,Tianjin University,Tianjin, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.12418888,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"23","issue":null,"first_page":"45","last_page":"51"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11896","display_name":"Opportunistic and Delay-Tolerant Networks","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9908000230789185,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.7270034551620483},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6836418509483337},{"id":"https://openalex.org/keywords/node","display_name":"Node (physics)","score":0.5631276369094849},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.5076838731765747},{"id":"https://openalex.org/keywords/sleep-mode","display_name":"Sleep mode","score":0.49974846839904785},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4868554472923279},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4853193163871765},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.47404003143310547},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.47021248936653137},{"id":"https://openalex.org/keywords/mechanism","display_name":"Mechanism (biology)","score":0.4570574462413788},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.45310351252555847},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4514634907245636},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4139483571052551},{"id":"https://openalex.org/keywords/energy-supply","display_name":"Energy supply","score":0.41300681233406067},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.3338736295700073},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21090847253799438},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.189208984375},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.18131756782531738}],"concepts":[{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.7270034551620483},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6836418509483337},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.5631276369094849},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.5076838731765747},{"id":"https://openalex.org/C57149124","wikidata":"https://www.wikidata.org/wiki/Q587346","display_name":"Sleep mode","level":4,"score":0.49974846839904785},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4868554472923279},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4853193163871765},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.47404003143310547},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.47021248936653137},{"id":"https://openalex.org/C89611455","wikidata":"https://www.wikidata.org/wiki/Q6804646","display_name":"Mechanism (biology)","level":2,"score":0.4570574462413788},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.45310351252555847},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4514634907245636},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4139483571052551},{"id":"https://openalex.org/C2776190866","wikidata":"https://www.wikidata.org/wiki/Q1341477","display_name":"Energy supply","level":3,"score":0.41300681233406067},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.3338736295700073},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21090847253799438},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.189208984375},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.18131756782531738},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111472728","wikidata":"https://www.wikidata.org/wiki/Q9471","display_name":"Epistemology","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/msn.2011.34","is_oa":false,"landing_page_url":"https://doi.org/10.1109/msn.2011.34","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 Seventh International Conference on Mobile Ad-hoc and Sensor Networks","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9100000262260437}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1958453179","https://openalex.org/W1976116245","https://openalex.org/W2011662871","https://openalex.org/W2012430168","https://openalex.org/W2014375599","https://openalex.org/W2102604933","https://openalex.org/W2106048836","https://openalex.org/W2106335692","https://openalex.org/W2111367044","https://openalex.org/W2116370666","https://openalex.org/W2124183814","https://openalex.org/W2134238238","https://openalex.org/W2153195119","https://openalex.org/W2153366747","https://openalex.org/W2161955777","https://openalex.org/W2167289038","https://openalex.org/W2167396179","https://openalex.org/W2366582521","https://openalex.org/W4251245171","https://openalex.org/W6683026643"],"related_works":["https://openalex.org/W2121237322","https://openalex.org/W1975451135","https://openalex.org/W2989915292","https://openalex.org/W2890570089","https://openalex.org/W2073793005","https://openalex.org/W2010304531","https://openalex.org/W2072191144","https://openalex.org/W1976279708","https://openalex.org/W2142061742","https://openalex.org/W2082024242"],"abstract_inverted_index":{"It":[0],"is":[1,21,99],"important":[2],"to":[3,25,67,103],"protect":[4,26],"power":[5,28],"supply":[6,29],"grid":[7],"system":[8,20],"against":[9],"various":[10],"damages":[11],"for":[12,39,55],"national":[13],"economics.":[14],"A":[15],"high-voltage":[16],"transmission":[17],"line":[18],"monitoring":[19],"an":[22,34,80],"effective":[23],"way":[24],"the":[27,52,59,69,74,111],"system.":[30,42],"This":[31],"paper":[32],"presents":[33],"energy-efficient":[35],"data":[36],"gathering":[37],"mechanism":[38,98],"such":[40],"a":[41,48],"Our":[43],"contributions":[44],"are":[45],"two-fold:":[46],"(1)":[47],"detailed":[49],"measurement":[50],"of":[51,85,93],"energy":[53,91,112],"consumption":[54,92,113],"wireless":[56],"nodes,":[57],"(2)":[58],"collaboration":[60],"between":[61],"backbone":[62,87],"network":[63,88],"nodes":[64],"and":[65,101],"subnets":[66],"implement":[68],"sleep-wakeup":[70],"mechanism.":[71],"To":[72],"validate":[73],"proposed":[75],"mechanism,":[76],"we":[77],"have":[78],"established":[79],"indoor":[81],"test":[82],"bed":[83],"consisting":[84],"8":[86],"nodes.":[89],"The":[90,107],"each":[94],"node":[95],"with":[96],"our":[97,119],"evaluated":[100],"compared":[102],"that":[104,110],"without":[105],"sleep.":[106],"results":[108],"show":[109],"has":[114],"decreased":[115],"by":[116,118],"24%":[117],"scheme.":[120]},"counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
