{"id":"https://openalex.org/W1975585606","doi":"https://doi.org/10.1109/mm.2013.31","title":"Scaling the Energy Proportionality Wall with KnightShift","display_name":"Scaling the Energy Proportionality Wall with KnightShift","publication_year":2013,"publication_date":"2013-03-27","ids":{"openalex":"https://openalex.org/W1975585606","doi":"https://doi.org/10.1109/mm.2013.31","mag":"1975585606"},"language":"en","primary_location":{"id":"doi:10.1109/mm.2013.31","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mm.2013.31","pdf_url":null,"source":{"id":"https://openalex.org/S59697426","display_name":"IEEE Micro","issn_l":"0272-1732","issn":["0272-1732","1937-4143"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Micro","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000712719","display_name":"Daniel Wong","orcid":"https://orcid.org/0000-0002-5376-7868"},"institutions":[{"id":"https://openalex.org/I1174212","display_name":"University of Southern California","ror":"https://ror.org/03taz7m60","country_code":"US","type":"education","lineage":["https://openalex.org/I1174212"]},{"id":"https://openalex.org/I2800817003","display_name":"California Southern University","ror":"https://ror.org/058zz0t50","country_code":"US","type":"education","lineage":["https://openalex.org/I2800817003"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Daniel Wong","raw_affiliation_strings":["Department of Electrical Engineering, University of Southern California, Los Angeles, CA, USA","University of Southern California"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Southern California, Los Angeles, CA, USA","institution_ids":["https://openalex.org/I1174212"]},{"raw_affiliation_string":"University of Southern California","institution_ids":["https://openalex.org/I2800817003","https://openalex.org/I1174212"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018033573","display_name":"Murali Annavaram","orcid":"https://orcid.org/0000-0002-4633-6867"},"institutions":[{"id":"https://openalex.org/I1174212","display_name":"University of Southern California","ror":"https://ror.org/03taz7m60","country_code":"US","type":"education","lineage":["https://openalex.org/I1174212"]},{"id":"https://openalex.org/I2800817003","display_name":"California Southern University","ror":"https://ror.org/058zz0t50","country_code":"US","type":"education","lineage":["https://openalex.org/I2800817003"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Murali Annavaram","raw_affiliation_strings":["Department of Electrical Engineering, University of Southern California, USA","University of Southern California"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Southern California, USA","institution_ids":["https://openalex.org/I1174212"]},{"raw_affiliation_string":"University of Southern California","institution_ids":["https://openalex.org/I2800817003","https://openalex.org/I1174212"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":6.6895,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.96251056,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"33","issue":"3","first_page":"28","last_page":"37"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10273","display_name":"IoT and Edge/Fog Computing","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10714","display_name":"Software-Defined Networks and 5G","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/server","display_name":"Server","score":0.8093888759613037},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7999557852745056},{"id":"https://openalex.org/keywords/proportionality","display_name":"Proportionality (law)","score":0.6934585571289062},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5713228583335876},{"id":"https://openalex.org/keywords/scaling","display_name":"Scaling","score":0.4717950224876404},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4697352349758148},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.41731393337249756},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.38553619384765625},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3605651259422302},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09709092974662781},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.0700002908706665}],"concepts":[{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.8093888759613037},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7999557852745056},{"id":"https://openalex.org/C183763965","wikidata":"https://www.wikidata.org/wiki/Q603959","display_name":"Proportionality (law)","level":2,"score":0.6934585571289062},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5713228583335876},{"id":"https://openalex.org/C99844830","wikidata":"https://www.wikidata.org/wiki/Q102441924","display_name":"Scaling","level":2,"score":0.4717950224876404},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4697352349758148},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.41731393337249756},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.38553619384765625},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3605651259422302},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09709092974662781},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0700002908706665},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mm.2013.31","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mm.2013.31","pdf_url":null,"source":{"id":"https://openalex.org/S59697426","display_name":"IEEE Micro","issn_l":"0272-1732","issn":["0272-1732","1937-4143"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Micro","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"},{"id":"https://openalex.org/F4320308668","display_name":"University of Southern California","ror":"https://ror.org/03taz7m60"},{"id":"https://openalex.org/F4320332180","display_name":"Defense Advanced Research Projects Agency","ror":"https://ror.org/02caytj08"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1997025365","https://openalex.org/W2100346277","https://openalex.org/W2116460500","https://openalex.org/W2139883663","https://openalex.org/W2143705506","https://openalex.org/W2146484001","https://openalex.org/W2149323767","https://openalex.org/W2155702343","https://openalex.org/W4241323966"],"related_works":["https://openalex.org/W2092530219","https://openalex.org/W4238814147","https://openalex.org/W2981543460","https://openalex.org/W3212262305","https://openalex.org/W12604237","https://openalex.org/W2388464034","https://openalex.org/W4225986597","https://openalex.org/W4214747436","https://openalex.org/W2953002963","https://openalex.org/W179829755"],"abstract_inverted_index":{"Measuring":[0],"energy":[1,35,49,62,77],"proportionality":[2,26,50,78],"accurately":[3],"and":[4,25,32,141],"understanding":[5],"the":[6,74,82,112],"reasons":[7],"for":[8],"disproportionality":[9],"are":[10,52],"critical":[11],"first":[12],"steps":[13],"in":[14],"designing":[15],"future":[16],"energy-efficient":[17,122],"servers.":[18],"This":[19],"article":[20],"presents":[21],"two":[22,121],"metrics-linear":[23],"deviation":[24],"gap-that":[27],"let":[28],"system":[29],"designers":[30],"analyze":[31],"understand":[33],"server":[34,57,89,114],"consumption":[36],"at":[37,67,79],"various":[38,56],"utilization":[39,58],"levels.":[40,59],"An":[41],"analysis":[42],"of":[43,76,132,139],"published":[44],"SPECpower":[45],"results":[46],"shows":[47],"that":[48],"improvements":[51],"not":[53],"uniform":[54],"across":[55],"Even":[60],"highly":[61],"proportional":[63],"servers":[64],"suffer":[65],"significantly":[66],"nonzero":[68],"but":[69],"low":[70,80],"utilizations.":[71],"To":[72],"address":[73],"lack":[75],"utilization,":[81],"authors":[83,126],"present":[84],"KnightShift,":[85],"a":[86,100,130,137],"server-level":[87],"heterogeneous":[88],"providing":[90],"an":[91],"active":[92],"low-power":[93,101],"mode.":[94],"KnightShift":[95,128],"is":[96],"tightly":[97],"coupled":[98],"with":[99],"compute":[102],"node":[103],"called":[104],"Knight.":[105],"Knight":[106],"responds":[107,115],"to":[108,117],"low-utilization":[109],"requests":[110],"whereas":[111],"primary":[113],"only":[116],"high-utilization":[118],"requests,":[119],"enabling":[120],"operating":[123],"regions.":[124],"The":[125],"evaluate":[127],"against":[129],"variety":[131],"real-world":[133],"datacenter":[134],"workloads":[135],"using":[136],"combination":[138],"prototyping":[140],"simulation.":[142]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":3},{"year":2013,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
