{"id":"https://openalex.org/W4412164331","doi":"https://doi.org/10.1109/memea65319.2025.11068104","title":"Robust Hand-Eye Calibration Workflow for Robotic Spine Surgery: Insights from a Cadaver Study","display_name":"Robust Hand-Eye Calibration Workflow for Robotic Spine Surgery: Insights from a Cadaver Study","publication_year":2025,"publication_date":"2025-05-28","ids":{"openalex":"https://openalex.org/W4412164331","doi":"https://doi.org/10.1109/memea65319.2025.11068104"},"language":"en","primary_location":{"id":"doi:10.1109/memea65319.2025.11068104","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea65319.2025.11068104","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Medical Measurements &amp;amp; Applications (MeMeA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5092828871","display_name":"Aswathaman Govindaraju","orcid":null},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"facility","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Aswathaman Govindaraju","raw_affiliation_strings":["Indian Institute of Technology, Madras,Department of Electrical Engineering,Chennai,India"],"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology, Madras,Department of Electrical Engineering,Chennai,India","institution_ids":["https://openalex.org/I24676775"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5105959013","display_name":"B. Ragu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210102197","display_name":"Healthcare Technology Innovation Centre","ror":"https://ror.org/017mw4x28","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210102197"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ragu B","raw_affiliation_strings":["Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras,Chennai,India"],"affiliations":[{"raw_affiliation_string":"Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras,Chennai,India","institution_ids":["https://openalex.org/I4210102197"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113309216","display_name":"Rakesh Kumar K","orcid":null},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"facility","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Rakesh Kumar K","raw_affiliation_strings":["Indian Institute of Technology, Madras,Department of Electrical Engineering,Chennai,India"],"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology, Madras,Department of Electrical Engineering,Chennai,India","institution_ids":["https://openalex.org/I24676775"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072193876","display_name":"A Shyam","orcid":"https://orcid.org/0000-0002-1618-0283"},"institutions":[{"id":"https://openalex.org/I4210102197","display_name":"Healthcare Technology Innovation Centre","ror":"https://ror.org/017mw4x28","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210102197"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Shyam A","raw_affiliation_strings":["Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras,Chennai,India"],"affiliations":[{"raw_affiliation_string":"Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras,Chennai,India","institution_ids":["https://openalex.org/I4210102197"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5058987412","display_name":"Manojkumar Lakshmanan","orcid":null},"institutions":[{"id":"https://openalex.org/I4210102197","display_name":"Healthcare Technology Innovation Centre","ror":"https://ror.org/017mw4x28","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210102197"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Manojkumar Lakshmanan","raw_affiliation_strings":["Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras,Chennai,India"],"affiliations":[{"raw_affiliation_string":"Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras,Chennai,India","institution_ids":["https://openalex.org/I4210102197"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056763944","display_name":"Mohanasankar Sivaprakasam","orcid":"https://orcid.org/0000-0002-6714-9147"},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"facility","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Mohanasankar Sivaprakasam","raw_affiliation_strings":["Indian Institute of Technology, Madras,Department of Electrical Engineering,Chennai,India"],"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology, Madras,Department of Electrical Engineering,Chennai,India","institution_ids":["https://openalex.org/I24676775"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5092828871"],"corresponding_institution_ids":["https://openalex.org/I24676775"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.34446663,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10916","display_name":"Surgical Simulation and Training","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10916","display_name":"Surgical Simulation and Training","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10776","display_name":"Spinal Fractures and Fixation Techniques","score":0.9962000250816345,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T14510","display_name":"Medical Imaging and Analysis","score":0.9950000047683716,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cadaver","display_name":"Cadaver","score":0.6925778388977051},{"id":"https://openalex.org/keywords/workflow","display_name":"Workflow","score":0.6592614054679871},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5564650297164917},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.531405508518219},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.5097095966339111},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.4247782826423645},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.27829548716545105},{"id":"https://openalex.org/keywords/anatomy","display_name":"Anatomy","score":0.25468653440475464},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.12177139520645142}],"concepts":[{"id":"https://openalex.org/C91762617","wikidata":"https://www.wikidata.org/wiki/Q48422","display_name":"Cadaver","level":2,"score":0.6925778388977051},{"id":"https://openalex.org/C177212765","wikidata":"https://www.wikidata.org/wiki/Q627335","display_name":"Workflow","level":2,"score":0.6592614054679871},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5564650297164917},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.531405508518219},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.5097095966339111},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.4247782826423645},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.27829548716545105},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.25468653440475464},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12177139520645142},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/memea65319.2025.11068104","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea65319.2025.11068104","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Medical Measurements &amp;amp; Applications (MeMeA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W2071523568","https://openalex.org/W2736526012","https://openalex.org/W2979526238","https://openalex.org/W3026559770","https://openalex.org/W3081842178","https://openalex.org/W4292873827","https://openalex.org/W4309089743","https://openalex.org/W4388562874","https://openalex.org/W4391023377"],"related_works":["https://openalex.org/W2772917594","https://openalex.org/W2036807459","https://openalex.org/W2058170566","https://openalex.org/W2755342338","https://openalex.org/W2166024367","https://openalex.org/W3116076068","https://openalex.org/W2229312674","https://openalex.org/W2951359407","https://openalex.org/W2079911747","https://openalex.org/W1969923398"],"abstract_inverted_index":{"This":[0],"paper":[1],"reports":[2],"the":[3,24,28,37,50,57,74,92,95,114,136,148,168,181,186,192,207,216,220,238],"development":[4],"and":[5,30,35,55,125,176,183,236],"cadaveric":[6],"validation":[7,87],"of":[8,94,107,121,157,167,185,206],"a":[9,118,140,153,227],"Hand-Eye":[10],"calibration":[11,42,104,209,235],"workflow":[12,21,150],"for":[13,53,71,232],"an":[14],"IR-camera-based":[15],"spine":[16,142],"surgical":[17,143],"robot.":[18],"The":[19,204],"proposed":[20,149],"directly":[22],"uses":[23],"data":[25,52,78],"captured":[26],"by":[27,97],"camera":[29],"robot":[31,75],"encoders":[32],"to":[33,48,67,76,90,134,179,201,225],"perform":[34],"verify":[36],"hand-eye":[38,103,234],"calibration.":[39],"A":[40,61,129],"self-reliant":[41,208],"integrity":[43,210],"checking":[44,211],"mechanism":[45,212],"is":[46,65],"devised":[47,66],"post-process":[49],"collected":[51],"verifying":[54,233],"estimating":[56,237],"overall":[58],"system":[59,96,138,154],"error.":[60],"custom":[62],"motion":[63],"planner":[64],"compute":[68],"collision-free":[69],"toolpaths":[70],"autonomously":[72],"moving":[73],"multiple":[77],"collection":[79],"sites":[80],"with":[81,117,215],"minimal":[82],"marker":[83],"occlusions.":[84],"An":[85],"in-house":[86],"was":[88,132,199],"conducted":[89,133],"measure":[91],"accuracy":[93,116,182],"subjecting":[98],"it":[99,198],"under":[100,191],"various":[101],"state-of-the-art":[102],"methods.":[105],"Out":[106],"180":[108],"screw":[109],"plans,":[110],"Hourad's":[111],"method":[112],"produced":[113],"best":[115],"positioning":[119],"error":[120,155],"0.97":[122],"(\u00b10.16)":[123],"mm":[124],"0.67":[126],"(\u00b10.09)":[127],"degrees.":[128],"cadaver":[130,221],"trial":[131],"evaluate":[135],"workflow-enabled":[137],"in":[139,152,219],"realistic":[141],"scenario.":[144],"When":[145],"performed":[146],"intra-operatively,":[147],"resulted":[151],"estimate":[156],"1.79":[158],"mm.":[159],"16":[160],"screws":[161,189],"were":[162,213],"instrumented":[163],"on":[164],"both":[165],"sides":[166],"L3,":[169],"L2,":[170],"L1,":[171],"T12,":[172],"T11,":[173],"T8,":[174],"T7,":[175],"T6":[177],"vertebrae":[178],"assess":[180],"performance":[184],"system.":[187],"13":[188],"fell":[190],"grade":[193],"0":[194],"breach":[195],"category":[196],"when":[197],"subjected":[200],"Rampersaud":[202],"classification.":[203],"results":[205,217],"in-line":[214],"observed":[218],"trial.":[222],"It":[223],"served":[224],"be":[226],"reliable":[228],"quality":[229],"control":[230],"routine":[231],"system's":[239],"accuracy.":[240]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
