{"id":"https://openalex.org/W2886386306","doi":"https://doi.org/10.1109/memea.2018.8438626","title":"Influence of Installing Method on Pulse Wave Signal in Blood Pressure Prediction by FBG Sensor","display_name":"Influence of Installing Method on Pulse Wave Signal in Blood Pressure Prediction by FBG Sensor","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2886386306","doi":"https://doi.org/10.1109/memea.2018.8438626","mag":"2886386306"},"language":"en","primary_location":{"id":"doi:10.1109/memea.2018.8438626","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea.2018.8438626","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110634763","display_name":"Shun Chino","orcid":null},"institutions":[{"id":"https://openalex.org/I137975476","display_name":"Shinshu University","ror":"https://ror.org/0244rem06","country_code":"JP","type":"education","lineage":["https://openalex.org/I137975476"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"Shun Chino","raw_affiliation_strings":["Graduate School of Science and Technology, Shinshu University, Ueda City, Nagano, Japan"],"affiliations":[{"raw_affiliation_string":"Graduate School of Science and Technology, Shinshu University, Ueda City, Nagano, Japan","institution_ids":["https://openalex.org/I137975476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102790426","display_name":"Hiroaki Ishizawa","orcid":"https://orcid.org/0000-0002-6574-6773"},"institutions":[{"id":"https://openalex.org/I137975476","display_name":"Shinshu University","ror":"https://ror.org/0244rem06","country_code":"JP","type":"education","lineage":["https://openalex.org/I137975476"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Hiroaki Ishizawa","raw_affiliation_strings":["Division of Smart Textiles, Institute of Fiber Engineering, ICCER, Shinshu University, Ueda City, Nagano, Japan"],"affiliations":[{"raw_affiliation_string":"Division of Smart Textiles, Institute of Fiber Engineering, ICCER, Shinshu University, Ueda City, Nagano, Japan","institution_ids":["https://openalex.org/I137975476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040506623","display_name":"Shouhei Koyama","orcid":"https://orcid.org/0000-0003-4297-7648"},"institutions":[{"id":"https://openalex.org/I137975476","display_name":"Shinshu University","ror":"https://ror.org/0244rem06","country_code":"JP","type":"education","lineage":["https://openalex.org/I137975476"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Shouhei Koyama","raw_affiliation_strings":["Faculty of Textile Science and Technology, Shinshu University, Ueda City, Nagano, Japan"],"affiliations":[{"raw_affiliation_string":"Faculty of Textile Science and Technology, Shinshu University, Ueda City, Nagano, Japan","institution_ids":["https://openalex.org/I137975476"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5068373132","display_name":"Keisaku Fujimoto","orcid":"https://orcid.org/0000-0002-6512-1757"},"institutions":[{"id":"https://openalex.org/I137975476","display_name":"Shinshu University","ror":"https://ror.org/0244rem06","country_code":"JP","type":"education","lineage":["https://openalex.org/I137975476"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Keisaku Fujimoto","raw_affiliation_strings":["School of Health Sciences, School of Medicine, Shinshu University, Matsumoto City, Nagano, Japan"],"affiliations":[{"raw_affiliation_string":"School of Health Sciences, School of Medicine, Shinshu University, Matsumoto City, Nagano, Japan","institution_ids":["https://openalex.org/I137975476"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5110634763"],"corresponding_institution_ids":["https://openalex.org/I137975476"],"apc_list":null,"apc_paid":null,"fwci":0.109,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.44286611,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":"17","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10640","display_name":"Spectroscopy and Chemometric Analyses","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/1602","display_name":"Analytical Chemistry"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fiber-bragg-grating","display_name":"Fiber Bragg grating","score":0.6883243918418884},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5943482518196106},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5024275779724121},{"id":"https://openalex.org/keywords/pressure-sensor","display_name":"Pressure sensor","score":0.498349666595459},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.4965236783027649},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.4938400387763977},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.48769959807395935},{"id":"https://openalex.org/keywords/pulse-wave","display_name":"Pulse wave","score":0.4808371961116791},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.4792311489582062},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.46273335814476013},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.4379822015762329},{"id":"https://openalex.org/keywords/optical-fiber","display_name":"Optical fiber","score":0.419671893119812},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.38130080699920654},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.17312976717948914},{"id":"https://openalex.org/keywords/laser","display_name":"Laser","score":0.15210700035095215},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.1364273726940155},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1298772692680359},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12267082929611206},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.0813010036945343}],"concepts":[{"id":"https://openalex.org/C43091971","wikidata":"https://www.wikidata.org/wiki/Q1397391","display_name":"Fiber Bragg grating","level":3,"score":0.6883243918418884},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5943482518196106},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5024275779724121},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.498349666595459},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.4965236783027649},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.4938400387763977},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.48769959807395935},{"id":"https://openalex.org/C172321821","wikidata":"https://www.wikidata.org/wiki/Q7259685","display_name":"Pulse wave","level":3,"score":0.4808371961116791},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.4792311489582062},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.46273335814476013},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.4379822015762329},{"id":"https://openalex.org/C194232370","wikidata":"https://www.wikidata.org/wiki/Q162","display_name":"Optical fiber","level":2,"score":0.419671893119812},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.38130080699920654},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.17312976717948914},{"id":"https://openalex.org/C520434653","wikidata":"https://www.wikidata.org/wiki/Q38867","display_name":"Laser","level":2,"score":0.15210700035095215},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1364273726940155},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1298772692680359},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12267082929611206},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.0813010036945343},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/memea.2018.8438626","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea.2018.8438626","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W416685935","https://openalex.org/W1594230933","https://openalex.org/W2058382695","https://openalex.org/W2073503722","https://openalex.org/W2107420073","https://openalex.org/W2166446427","https://openalex.org/W2167925220","https://openalex.org/W2334369229","https://openalex.org/W2513162681","https://openalex.org/W2529008282","https://openalex.org/W2565862792","https://openalex.org/W2593891259","https://openalex.org/W2781507917"],"related_works":["https://openalex.org/W4317951993","https://openalex.org/W2324609977","https://openalex.org/W4309145825","https://openalex.org/W4206804491","https://openalex.org/W1973127455","https://openalex.org/W2132863420","https://openalex.org/W3021632479","https://openalex.org/W2984836626","https://openalex.org/W2034348654","https://openalex.org/W236783687"],"abstract_inverted_index":{"Vital":[0],"signs":[1,65],"such":[2,66],"as":[3,67],"pulse":[4,68,109,126,153,209,265,278],"and":[5,39,51,69,73,184,222],"blood":[6,36,70,177,181,189,205,219,223,258],"pressure":[7,31,37,71,206,224,259],"change":[8],"greatly":[9,192],"due":[10],"to":[11,18,53,62,97,106,169,245,276],"mental":[12],"factors.":[13],"Therefore,":[14,57,208],"it":[15,162,166,253,273],"is":[16,32,42,49,84,104,116,156,163,167,191,212,225,241,261,274],"desired":[17],"continuously":[19,72],"measure":[20,54,63,107,170,277],"unconsciously.":[21],"However,":[22,161],"the":[23,29,46,88,91,108,113,125,137,141,146,152,171,176,188,230,234,238,248,264,270,282],"oscillometric":[24],"method":[25],"which":[26,194],"measures":[27],"using":[28,75,143,214,263],"cuff":[30],"generally":[33],"used":[34],"for":[35,204],"measurement,":[38],"continuous":[40],"measurement":[41,211],"impossible.":[43],"In":[44,119],"addition,":[45],"measuring":[47],"instrument":[48],"large":[50],"difficult":[52,168],"under":[55],"unconsciousness.":[56],"we":[58,122],"are":[59],"conducting":[60],"research":[61],"vital":[64],"noninvasively":[74],"Fiber":[76],"Bragg":[77],"Grating":[78],"(FBG)":[79],"sensor.":[80,118],"The":[81],"FBG":[82,102,114,131,138,271],"sensor":[83,103,115,132,139],"created":[85],"by":[86,180,269],"irradiating":[87],"core":[89],"of":[90,151,175,201,236],"optical":[92],"fiber":[93],"with":[94,130],"ultraviolet":[95],"rays":[96],"form":[98],"a":[99,144,215,228],"diffraction":[100],"grating.":[101],"able":[105],"wave":[110,127,154,173,210,266,279,284],"signal":[111,128,155,267],"since":[112],"distortion":[117],"this":[120],"paper,":[121],"confirmed":[123],"that":[124,165,217,256],"changes":[129],"installing":[133],"method.":[134],"By":[135],"pressing":[136],"against":[140],"skin":[142],"clip,":[145],"S":[147],"/":[148],"N":[149],"ratio":[150],"improved":[157,242],"about":[158],"nine":[159],"times.":[160],"suggested":[164],"reflected":[172,283],"component":[174],"flow":[178],"caused":[179],"vessel":[182,190,220],"branching":[183],"capillary":[185],"resistance":[186],"when":[187,257],"deformed,":[193],"has":[195],"an":[196],"adverse":[197],"effect":[198],"on":[199],"construction":[200],"calibration":[202,239],"curve":[203,240],"prediction.":[207],"performed":[213,262],"clip":[216],"minimized":[218],"deformation,":[221],"predicted.":[226],"As":[227],"result,":[229],"correlation":[231],"coefficient":[232],"at":[233,247],"time":[235],"constructing":[237],"from":[243],"0.48":[244],"0.88":[246],"maximum.":[249],"From":[250],"these":[251],"facts,":[252],"was":[254],"found":[255],"prediction":[260],"measured":[268],"sensor,":[272],"necessary":[275],"without":[280],"losing":[281],"component.":[285]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
