{"id":"https://openalex.org/W2739227564","doi":"https://doi.org/10.1109/memea.2017.7985869","title":"System design to prevent Ventilator Associated Pneumonia","display_name":"System design to prevent Ventilator Associated Pneumonia","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2739227564","doi":"https://doi.org/10.1109/memea.2017.7985869","mag":"2739227564"},"language":"en","primary_location":{"id":"doi:10.1109/memea.2017.7985869","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea.2017.7985869","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103075071","display_name":"B S Renganathan","orcid":null},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"facility","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Renganathan B S","raw_affiliation_strings":["Dept. of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India"],"affiliations":[{"raw_affiliation_string":"Dept. of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India","institution_ids":["https://openalex.org/I24676775"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054706248","display_name":"S P Preejith","orcid":"https://orcid.org/0000-0002-0634-1194"},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"facility","lineage":["https://openalex.org/I24676775"]},{"id":"https://openalex.org/I4210102197","display_name":"Healthcare Technology Innovation Centre","ror":"https://ror.org/017mw4x28","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210102197"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Preejith S P","raw_affiliation_strings":["Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India"],"affiliations":[{"raw_affiliation_string":"Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India","institution_ids":["https://openalex.org/I4210102197","https://openalex.org/I24676775"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065452083","display_name":"Sridhar Nagaiyan","orcid":null},"institutions":[{"id":"https://openalex.org/I2800392559","display_name":"Royal Stoke University Hospital","ror":"https://ror.org/01dx1mr58","country_code":"GB","type":"healthcare","lineage":["https://openalex.org/I2800115762","https://openalex.org/I2800392559"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Sridhar Nagaiyan","raw_affiliation_strings":["Honorary Consultant in critical care, Royal Stoke Hospital, UK"],"affiliations":[{"raw_affiliation_string":"Honorary Consultant in critical care, Royal Stoke Hospital, UK","institution_ids":["https://openalex.org/I2800392559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020295407","display_name":"Jayaraj Joseph","orcid":"https://orcid.org/0000-0002-7279-9099"},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"facility","lineage":["https://openalex.org/I24676775"]},{"id":"https://openalex.org/I4210102197","display_name":"Healthcare Technology Innovation Centre","ror":"https://ror.org/017mw4x28","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210102197"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Jayaraj Joseph","raw_affiliation_strings":["Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India"],"affiliations":[{"raw_affiliation_string":"Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India","institution_ids":["https://openalex.org/I4210102197","https://openalex.org/I24676775"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056763944","display_name":"Mohanasankar Sivaprakasam","orcid":"https://orcid.org/0000-0002-6714-9147"},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"facility","lineage":["https://openalex.org/I24676775"]},{"id":"https://openalex.org/I4210102197","display_name":"Healthcare Technology Innovation Centre","ror":"https://ror.org/017mw4x28","country_code":"IN","type":"facility","lineage":["https://openalex.org/I4210102197"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Mohanasankar Sivaprakasam","raw_affiliation_strings":["Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India"],"affiliations":[{"raw_affiliation_string":"Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India","institution_ids":["https://openalex.org/I4210102197","https://openalex.org/I24676775"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5103075071"],"corresponding_institution_ids":["https://openalex.org/I24676775"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.14771407,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"3","issue":null,"first_page":"165","last_page":"170"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11681","display_name":"Nosocomial Infections in ICU","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10867","display_name":"Intensive Care Unit Cognitive Disorders","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ventilator-associated-pneumonia","display_name":"Ventilator-associated pneumonia","score":0.8173369765281677},{"id":"https://openalex.org/keywords/intensive-care-unit","display_name":"Intensive care unit","score":0.674781084060669},{"id":"https://openalex.org/keywords/pneumonia","display_name":"Pneumonia","score":0.6289737224578857},{"id":"https://openalex.org/keywords/bundle","display_name":"Bundle","score":0.6037098169326782},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.5879456400871277},{"id":"https://openalex.org/keywords/intensive-care-medicine","display_name":"Intensive care medicine","score":0.5875017046928406},{"id":"https://openalex.org/keywords/mechanical-ventilator","display_name":"Mechanical ventilator","score":0.47313371300697327},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.4658656120300293},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.45422911643981934},{"id":"https://openalex.org/keywords/critically-ill","display_name":"Critically ill","score":0.4296044111251831},{"id":"https://openalex.org/keywords/mechanical-ventilation","display_name":"Mechanical ventilation","score":0.4257306754589081},{"id":"https://openalex.org/keywords/medical-emergency","display_name":"Medical emergency","score":0.3320696949958801},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.27047497034072876},{"id":"https://openalex.org/keywords/nursing","display_name":"Nursing","score":0.14076995849609375},{"id":"https://openalex.org/keywords/anesthesia","display_name":"Anesthesia","score":0.1200782060623169},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.1119336187839508},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.0900619626045227}],"concepts":[{"id":"https://openalex.org/C2777184939","wikidata":"https://www.wikidata.org/wiki/Q7920253","display_name":"Ventilator-associated pneumonia","level":3,"score":0.8173369765281677},{"id":"https://openalex.org/C2776376669","wikidata":"https://www.wikidata.org/wiki/Q5094647","display_name":"Intensive care unit","level":2,"score":0.674781084060669},{"id":"https://openalex.org/C2777914695","wikidata":"https://www.wikidata.org/wiki/Q12192","display_name":"Pneumonia","level":2,"score":0.6289737224578857},{"id":"https://openalex.org/C2778134712","wikidata":"https://www.wikidata.org/wiki/Q1047307","display_name":"Bundle","level":2,"score":0.6037098169326782},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.5879456400871277},{"id":"https://openalex.org/C177713679","wikidata":"https://www.wikidata.org/wiki/Q679690","display_name":"Intensive care medicine","level":1,"score":0.5875017046928406},{"id":"https://openalex.org/C3018642899","wikidata":"https://www.wikidata.org/wiki/Q813243","display_name":"Mechanical ventilator","level":3,"score":0.47313371300697327},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.4658656120300293},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.45422911643981934},{"id":"https://openalex.org/C2991859549","wikidata":"https://www.wikidata.org/wiki/Q679690","display_name":"Critically ill","level":2,"score":0.4296044111251831},{"id":"https://openalex.org/C2777080012","wikidata":"https://www.wikidata.org/wiki/Q3766250","display_name":"Mechanical ventilation","level":2,"score":0.4257306754589081},{"id":"https://openalex.org/C545542383","wikidata":"https://www.wikidata.org/wiki/Q2751242","display_name":"Medical emergency","level":1,"score":0.3320696949958801},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.27047497034072876},{"id":"https://openalex.org/C159110408","wikidata":"https://www.wikidata.org/wiki/Q121176","display_name":"Nursing","level":1,"score":0.14076995849609375},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.1200782060623169},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.1119336187839508},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0900619626045227},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/memea.2017.7985869","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea.2017.7985869","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.8799999952316284,"display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1957286757","https://openalex.org/W1992314710","https://openalex.org/W2007349480","https://openalex.org/W2061167474","https://openalex.org/W2075326740","https://openalex.org/W2077481681","https://openalex.org/W2123641148","https://openalex.org/W2132185712","https://openalex.org/W2143385226","https://openalex.org/W2160146756","https://openalex.org/W2322707526"],"related_works":["https://openalex.org/W2379077812","https://openalex.org/W3030773518","https://openalex.org/W2889323967","https://openalex.org/W2382819419","https://openalex.org/W2381930973","https://openalex.org/W2349996811","https://openalex.org/W2348272311","https://openalex.org/W3177265913","https://openalex.org/W2369715255","https://openalex.org/W2299958443"],"abstract_inverted_index":{"Ventilator":[0],"Associated":[1],"Pneumonia":[2],"(VAP)":[3],"is":[4,11,45,77,90,110,118],"a":[5,107,114,132,154],"major":[6],"problem":[7],"in":[8,26,47],"hospitals":[9,48],"and":[10,32,103,131,140,164,172],"the":[12,27,64,73,81,121,126,137,147,159,167,174],"leading":[13],"cause":[14],"of":[15,51,56,69,72,100],"deaths":[16],"among":[17],"all":[18],"hospital-acquired":[19],"infections.":[20],"Critically":[21],"ill":[22],"subjects":[23],"who":[24],"are":[25,37],"intensive":[28],"care":[29],"unit":[30],"(ICU)":[31],"under":[33,153],"mechanical":[34],"ventilator":[35],"support":[36],"more":[38],"prone":[39],"to":[40,78,98,120,143],"VAP.":[41,52],"Traditionally,":[42],"VAP":[43,53,148],"bundle":[44,54,149],"used":[46],"for":[49],"prevention":[50],"consists":[55],"five":[57],"protocols":[58],"which":[59,112,117],"must":[60],"be":[61],"observed":[62],"by":[63,95],"caregiver":[65,138,175],"at":[66,86],"regular":[67],"intervals":[68],"time.":[70],"One":[71],"critical":[74],"protocol":[75],"steps":[76],"always":[79,92],"maintain":[80],"patient's":[82,122,127,168],"head":[83,128,169],"up":[84,129,170],"angle":[85,130,171],"30-45":[87],"degrees.":[88],"This":[89],"not":[91],"strictly":[93],"followed":[94],"caregivers":[96],"due":[97],"lack":[99],"continuous":[101],"monitoring":[102,125],"alert":[104],"mechanisms.":[105],"Hence":[106],"novel":[108],"method":[109],"proposed":[111],"includes":[113],"wearable":[115],"sensor":[116],"attached":[119],"body,":[123],"continuously":[124,162],"tablet-based":[133],"system":[134,160],"that":[135,158],"reminds":[136],"as":[139],"when":[141,176],"required":[142],"help":[144],"comply":[145],"with":[146],"protocols.":[150],"Preliminary":[151],"studies":[152],"controlled":[155],"setting":[156],"revealed":[157],"can":[161],"monitor":[163],"accurately":[165],"detect":[166],"remind":[173],"required.":[177]},"counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
