{"id":"https://openalex.org/W2109633771","doi":"https://doi.org/10.1109/iscas.2005.1465274","title":"Super-Stable Energy Based Switching Control Scheme for DC-DC Buck Converter Circuits","display_name":"Super-Stable Energy Based Switching Control Scheme for DC-DC Buck Converter Circuits","publication_year":2005,"publication_date":"2005-07-27","ids":{"openalex":"https://openalex.org/W2109633771","doi":"https://doi.org/10.1109/iscas.2005.1465274","mag":"2109633771"},"language":"en","primary_location":{"id":"doi:10.1109/iscas.2005.1465274","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2005.1465274","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2005 IEEE International Symposium on Circuits and Systems","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021818752","display_name":"Priya Gupta","orcid":"https://orcid.org/0000-0002-5334-1824"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"P. Gupta","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000212663","display_name":"A. K. Patra","orcid":"https://orcid.org/0000-0001-8141-4800"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"A. Patra","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I145894827"],"apc_list":null,"apc_paid":null,"fwci":3.401,"has_fulltext":false,"cited_by_count":28,"citation_normalized_percentile":{"value":0.93507752,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"3063","last_page":"3066"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10244","display_name":"Chaos control and synchronization","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/3109","display_name":"Statistical and Nonlinear Physics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10244","display_name":"Chaos control and synchronization","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/3109","display_name":"Statistical and Nonlinear Physics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9927999973297119,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.98580002784729,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inductor","display_name":"Inductor","score":0.7981340885162354},{"id":"https://openalex.org/keywords/ripple","display_name":"Ripple","score":0.7352081537246704},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.6662415266036987},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.646375834941864},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5843719244003296},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.5750248432159424},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.4474310576915741},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.41168588399887085},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.34177619218826294},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.28226208686828613},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2599167823791504},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.2545194625854492},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.21751540899276733},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.16077789664268494}],"concepts":[{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.7981340885162354},{"id":"https://openalex.org/C2779599953","wikidata":"https://www.wikidata.org/wiki/Q1776117","display_name":"Ripple","level":3,"score":0.7352081537246704},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.6662415266036987},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.646375834941864},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5843719244003296},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.5750248432159424},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.4474310576915741},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.41168588399887085},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.34177619218826294},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28226208686828613},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2599167823791504},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2545194625854492},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21751540899276733},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.16077789664268494},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iscas.2005.1465274","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iscas.2005.1465274","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2005 IEEE International Symposium on Circuits and Systems","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1596063655","https://openalex.org/W1925088515","https://openalex.org/W2118145595","https://openalex.org/W2139526574","https://openalex.org/W2149794178","https://openalex.org/W2152088109","https://openalex.org/W2169605656"],"related_works":["https://openalex.org/W4229441739","https://openalex.org/W4303411445","https://openalex.org/W4207040089","https://openalex.org/W2384455639","https://openalex.org/W1519622926","https://openalex.org/W2606001169","https://openalex.org/W4280567982","https://openalex.org/W1535034088","https://openalex.org/W2725083887","https://openalex.org/W3048189144"],"abstract_inverted_index":{"This":[0],"paper":[1],"has":[2,106],"proposed":[3,96],"a":[4,107],"new":[5],"energy":[6,53],"based":[7],"switching":[8,28],"scheme":[9,98],"for":[10],"controlling":[11],"DC-DC":[12],"buck":[13],"converter":[14],"circuits":[15],"and":[16,26,38,82,89,103],"analysed":[17],"its":[18],"stability.":[19],"There":[20],"are":[21],"three":[22,31],"modes":[23,32],"of":[24,52,71],"operations,":[25],"the":[27,35,39,50,63,72,95],"among":[29],"these":[30],"depends":[33],"on":[34],"reference":[36,41,45,56],"voltage":[37,57,64,74],"inductor":[40,44],"current.":[42],"The":[43,55,85],"current":[46],"is":[47,58,99],"calculated":[48],"by":[49],"principle":[51],"balance.":[54],"designed":[59],"to":[60,80],"ensure":[61],"that":[62,94],"ripple":[65],"as":[66,68],"well":[67],"average":[69],"value":[70],"output":[73],"remain":[75],"approximately":[76],"constant":[77],"in":[78,104],"response":[79],"line":[81],"load":[83],"disturbances.":[84],"phase":[86],"plane":[87],"analysis":[88,92],"sensitivity":[90],"matrix":[91],"show":[93],"control":[97],"free":[100],"from":[101],"chaos":[102],"fact":[105],"super-stable":[108],"orbit.":[109]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2012,"cited_by_count":3}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
