{"id":"https://openalex.org/W3013921049","doi":"https://doi.org/10.1109/icst46873.2019.9047741","title":"A Portable Device for Measuring Heart Rate in Comparison with the Pressure Applied for Light Penetration in Skin Surface","display_name":"A Portable Device for Measuring Heart Rate in Comparison with the Pressure Applied for Light Penetration in Skin Surface","publication_year":2019,"publication_date":"2019-12-01","ids":{"openalex":"https://openalex.org/W3013921049","doi":"https://doi.org/10.1109/icst46873.2019.9047741","mag":"3013921049"},"language":"en","primary_location":{"id":"doi:10.1109/icst46873.2019.9047741","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icst46873.2019.9047741","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 13th International Conference on Sensing Technology (ICST)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029951823","display_name":"Kshitij Shakya","orcid":"https://orcid.org/0000-0001-5048-8030"},"institutions":[{"id":"https://openalex.org/I9579091","display_name":"Indian Institute of Technology Mandi","ror":"https://ror.org/05r9r2f34","country_code":"IN","type":"education","lineage":["https://openalex.org/I9579091"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Kshitij Shakya","raw_affiliation_strings":["Biomedical System Laboratory, MANAS Group, School of Computing & Electrical Engineering Indian Institute of Technology Mandi, Mandi, India"],"affiliations":[{"raw_affiliation_string":"Biomedical System Laboratory, MANAS Group, School of Computing & Electrical Engineering Indian Institute of Technology Mandi, Mandi, India","institution_ids":["https://openalex.org/I9579091"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040162305","display_name":"Prateek Kumar Sonker","orcid":null},"institutions":[{"id":"https://openalex.org/I9579091","display_name":"Indian Institute of Technology Mandi","ror":"https://ror.org/05r9r2f34","country_code":"IN","type":"education","lineage":["https://openalex.org/I9579091"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Prateek Kumar Sonker","raw_affiliation_strings":["Biomedical System Laboratory, MANAS Group, School of Computing & Electrical Engineering Indian Institute of Technology Mandi, Mandi, India"],"affiliations":[{"raw_affiliation_string":"Biomedical System Laboratory, MANAS Group, School of Computing & Electrical Engineering Indian Institute of Technology Mandi, Mandi, India","institution_ids":["https://openalex.org/I9579091"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5041399117","display_name":"Shubhaiit Roy Chowdhury","orcid":null},"institutions":[{"id":"https://openalex.org/I9579091","display_name":"Indian Institute of Technology Mandi","ror":"https://ror.org/05r9r2f34","country_code":"IN","type":"education","lineage":["https://openalex.org/I9579091"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Shubhaiit Roy Chowdhury","raw_affiliation_strings":["Biomedical System Laboratory, MANAS Group, School of Computing & Electrical Engineering Indian Institute of Technology Mandi, Mandi, India"],"affiliations":[{"raw_affiliation_string":"Biomedical System Laboratory, MANAS Group, School of Computing & Electrical Engineering Indian Institute of Technology Mandi, Mandi, India","institution_ids":["https://openalex.org/I9579091"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5029951823"],"corresponding_institution_ids":["https://openalex.org/I9579091"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.18302757,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"73","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11324","display_name":"Spectroscopy Techniques in Biomedical and Chemical Research","score":0.979200005531311,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photodiode","display_name":"Photodiode","score":0.7488223910331726},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.6011004447937012},{"id":"https://openalex.org/keywords/microcontroller","display_name":"Microcontroller","score":0.5894230604171753},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.5510981678962708},{"id":"https://openalex.org/keywords/wavelength","display_name":"Wavelength","score":0.5155634880065918},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.5122982263565063},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5000240802764893},{"id":"https://openalex.org/keywords/transmitter","display_name":"Transmitter","score":0.486970990896225},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.48099812865257263},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.46025216579437256},{"id":"https://openalex.org/keywords/penetration","display_name":"Penetration (warfare)","score":0.45830467343330383},{"id":"https://openalex.org/keywords/light-emitting-diode","display_name":"Light-emitting diode","score":0.4551647901535034},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.4305674731731415},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.42274850606918335},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3313622772693634},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3142755627632141},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.294935941696167},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.22942408919334412},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1834717094898224},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.133528470993042}],"concepts":[{"id":"https://openalex.org/C751236","wikidata":"https://www.wikidata.org/wiki/Q175943","display_name":"Photodiode","level":2,"score":0.7488223910331726},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.6011004447937012},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.5894230604171753},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.5510981678962708},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.5155634880065918},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5122982263565063},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5000240802764893},{"id":"https://openalex.org/C47798520","wikidata":"https://www.wikidata.org/wiki/Q190157","display_name":"Transmitter","level":3,"score":0.486970990896225},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.48099812865257263},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.46025216579437256},{"id":"https://openalex.org/C80107235","wikidata":"https://www.wikidata.org/wiki/Q7162625","display_name":"Penetration (warfare)","level":2,"score":0.45830467343330383},{"id":"https://openalex.org/C176666156","wikidata":"https://www.wikidata.org/wiki/Q25504","display_name":"Light-emitting diode","level":2,"score":0.4551647901535034},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.4305674731731415},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.42274850606918335},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3313622772693634},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3142755627632141},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.294935941696167},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.22942408919334412},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1834717094898224},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.133528470993042},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icst46873.2019.9047741","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icst46873.2019.9047741","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 13th International Conference on Sensing Technology (ICST)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W125925698","https://openalex.org/W1967111656","https://openalex.org/W1967272767","https://openalex.org/W1980998480","https://openalex.org/W2003297662","https://openalex.org/W2037391645","https://openalex.org/W2132658518","https://openalex.org/W2161769766","https://openalex.org/W2404519819","https://openalex.org/W6683455536"],"related_works":["https://openalex.org/W4316095964","https://openalex.org/W1977514416","https://openalex.org/W1508801824","https://openalex.org/W3103825119","https://openalex.org/W2105026576","https://openalex.org/W2033236975","https://openalex.org/W2140280965","https://openalex.org/W2184010844","https://openalex.org/W4255002149","https://openalex.org/W2046378968"],"abstract_inverted_index":{"This":[0],"paper":[1,126],"describes":[2],"a":[3,14,67,77,99],"new":[4,78],"technique":[5],"which":[6],"measures":[7],"the":[8,18,22,31,40,46,59,64,72,97,106,115,125,129,137],"extent":[9],"of":[10,51,131,145],"light":[11,44],"penetration":[12],"into":[13,30],"skin":[15,32,47],"by":[16,91,114],"measuring":[17],"force":[19,54],"applied":[20,56,138],"on":[21,48,105],"source":[23],"and":[24,61,63,118,141],"detector":[25],"to":[26,57,123],"push":[27,58],"them":[28],"deep":[29],"for":[33],"NIR":[34],"Spectroscopy.":[35],"The":[36,109],"current":[37],"research":[38],"analyses":[39],"transmitted":[41],"or":[42],"reflected":[43],"from":[45],"an":[49],"account":[50],"how":[52],"much":[53],"was":[55],"transmitter":[60],"receiver":[62],"result":[65],"shows":[66,128,142],"linear":[68],"increase":[69],"in":[70,134],"both":[71],"quantities.":[73],"To":[74,95],"achieve":[75],"this,":[76,124],"device":[79],"has":[80,102],"been":[81,103],"prepared":[82],"containing":[83],"two":[84],"different":[85,88,93,143,148],"LEDs":[86],"having":[87],"wavelength":[89],"surrounded":[90],"four":[92],"photodiodes.":[94],"measure":[96],"force,":[98],"stain":[100],"gauge":[101],"installed":[104],"opposite":[107],"sides.":[108],"sensing":[110],"unit":[111],"is":[112],"followed":[113],"signal":[116,133],"conditioning":[117],"microcontroller":[119],"circuit.":[120],"In":[121],"addition":[122],"also":[127],"waveforms":[130],"PPG":[132],"accordance":[135],"with":[136,147],"increased":[139],"pressure":[140],"types":[144],"shapes":[146],"applies":[149],"pressure.":[150]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
