{"id":"https://openalex.org/W1556934246","doi":"https://doi.org/10.1109/icit.2015.7125294","title":"Unbalance in power systems: Case study","display_name":"Unbalance in power systems: Case study","publication_year":2015,"publication_date":"2015-03-01","ids":{"openalex":"https://openalex.org/W1556934246","doi":"https://doi.org/10.1109/icit.2015.7125294","mag":"1556934246"},"language":"en","primary_location":{"id":"doi:10.1109/icit.2015.7125294","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icit.2015.7125294","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Industrial Technology (ICIT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084917798","display_name":"Mohammed Albadi","orcid":"https://orcid.org/0000-0002-0652-7829"},"institutions":[{"id":"https://openalex.org/I47818738","display_name":"Sultan Qaboos University","ror":"https://ror.org/04wq8zb47","country_code":"OM","type":"education","lineage":["https://openalex.org/I47818738"]}],"countries":["OM"],"is_corresponding":true,"raw_author_name":"M. H. Albadi","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat, Oman","Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat, Oman","institution_ids":["https://openalex.org/I47818738"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman","institution_ids":["https://openalex.org/I47818738"]}]},{"author_position":"middle","author":{"id":null,"display_name":"A. S. Al Hinai","orcid":null},"institutions":[{"id":"https://openalex.org/I47818738","display_name":"Sultan Qaboos University","ror":"https://ror.org/04wq8zb47","country_code":"OM","type":"education","lineage":["https://openalex.org/I47818738"]}],"countries":["OM"],"is_corresponding":false,"raw_author_name":"A. S. Al Hinai","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Sultan Qaboos University, Oman","Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, Oman","institution_ids":["https://openalex.org/I47818738"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman","institution_ids":["https://openalex.org/I47818738"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110639666","display_name":"A. H. Al\u2010Badi","orcid":null},"institutions":[{"id":"https://openalex.org/I47818738","display_name":"Sultan Qaboos University","ror":"https://ror.org/04wq8zb47","country_code":"OM","type":"education","lineage":["https://openalex.org/I47818738"]}],"countries":["OM"],"is_corresponding":false,"raw_author_name":"A. H. Al-Badi","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat, Oman","Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat, Oman","institution_ids":["https://openalex.org/I47818738"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman","institution_ids":["https://openalex.org/I47818738"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070036916","display_name":"M. S. Al Riyami","orcid":null},"institutions":[{"id":"https://openalex.org/I197507618","display_name":"Oman Medical College","ror":"https://ror.org/00eckk830","country_code":"OM","type":"healthcare","lineage":["https://openalex.org/I197507618"]}],"countries":["OM"],"is_corresponding":false,"raw_author_name":"M. S. Al Riyami","raw_affiliation_strings":["Oman Electricity Transmission Company"],"affiliations":[{"raw_affiliation_string":"Oman Electricity Transmission Company","institution_ids":["https://openalex.org/I197507618"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054102953","display_name":"S. M. Al Hinai","orcid":null},"institutions":[{"id":"https://openalex.org/I47818738","display_name":"Sultan Qaboos University","ror":"https://ror.org/04wq8zb47","country_code":"OM","type":"education","lineage":["https://openalex.org/I47818738"]}],"countries":["OM"],"is_corresponding":false,"raw_author_name":"S. M. Al Hinai","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Sultan Qaboos University, Oman","Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, Oman","institution_ids":["https://openalex.org/I47818738"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman","institution_ids":["https://openalex.org/I47818738"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073390695","display_name":"Rashid Al Abri","orcid":"https://orcid.org/0000-0001-9118-6880"},"institutions":[{"id":"https://openalex.org/I47818738","display_name":"Sultan Qaboos University","ror":"https://ror.org/04wq8zb47","country_code":"OM","type":"education","lineage":["https://openalex.org/I47818738"]}],"countries":["OM"],"is_corresponding":false,"raw_author_name":"R. S. Al Abri","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat, OM","Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat, OM","institution_ids":["https://openalex.org/I47818738"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Sultan Qaboos University, PO Box 33, Muscat 123, Oman","institution_ids":["https://openalex.org/I47818738"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5084917798"],"corresponding_institution_ids":["https://openalex.org/I47818738"],"apc_list":null,"apc_paid":null,"fwci":0.8007,"has_fulltext":false,"cited_by_count":24,"citation_normalized_percentile":{"value":0.75466515,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1407","last_page":"1411"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.603678822517395},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5305246114730835},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5035921931266785},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.49428439140319824},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.49012312293052673},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.48354339599609375},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4455045759677887},{"id":"https://openalex.org/keywords/national-grid","display_name":"National Grid","score":0.4124220013618469},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.41229164600372314},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.41086268424987793},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.30937081575393677},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.1275520920753479},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07484963536262512}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.603678822517395},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5305246114730835},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5035921931266785},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.49428439140319824},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.49012312293052673},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.48354339599609375},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4455045759677887},{"id":"https://openalex.org/C2779553522","wikidata":"https://www.wikidata.org/wiki/Q15261121","display_name":"National Grid","level":3,"score":0.4124220013618469},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.41229164600372314},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.41086268424987793},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.30937081575393677},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.1275520920753479},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07484963536262512},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icit.2015.7125294","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icit.2015.7125294","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Industrial Technology (ICIT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W563237220","https://openalex.org/W2103790643","https://openalex.org/W2108620848","https://openalex.org/W2121499406","https://openalex.org/W2144680725","https://openalex.org/W3143127938","https://openalex.org/W3149700255","https://openalex.org/W4232254893","https://openalex.org/W4249806371"],"related_works":["https://openalex.org/W1982412832","https://openalex.org/W4244464241","https://openalex.org/W2384573129","https://openalex.org/W2351224547","https://openalex.org/W2358945257","https://openalex.org/W2375106342","https://openalex.org/W2225081615","https://openalex.org/W3127448532","https://openalex.org/W1999380447","https://openalex.org/W2171016170"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,12],"literature":[4],"review":[5,27],"about":[6,15],"unbalance":[7,16,29,45],"in":[8,18,59],"power":[9],"systems":[10],"and":[11,37,43,75],"case":[13],"study":[14],"measurements":[17,46],"the":[19,53,60],"Main":[20],"Interconnected":[21],"Network":[22],"(MIS)":[23],"of":[24,28,62],"Oman.":[25],"A":[26],"causes,":[30],"negative":[31],"impacts,":[32],"mitigation":[33],"techniques,":[34],"quantification":[35],"indices":[36],"limits":[38,71],"are":[39,64,68],"presented.":[40],"Moreover,":[41],"voltage":[42],"current":[44],"at":[47],"three":[48,54],"grid":[49],"stations":[50],"that":[51],"supply":[52],"main":[55],"industrial":[56],"areas":[57],"located":[58],"MIS":[61],"Oman":[63],"conducted.":[65],"Measurement":[66],"results":[67],"compared":[69],"with":[70],"specified":[72],"by":[73],"national":[74],"international":[76],"standards.":[77]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":3},{"year":2016,"cited_by_count":1}],"updated_date":"2026-03-25T23:56:10.502304","created_date":"2025-10-10T00:00:00"}
