{"id":"https://openalex.org/W2907190532","doi":"https://doi.org/10.1109/icarcv.2018.8581339","title":"Actuator and Sensor Fault Diagnosis for Wind Energy Conversion Systems","display_name":"Actuator and Sensor Fault Diagnosis for Wind Energy Conversion Systems","publication_year":2018,"publication_date":"2018-11-01","ids":{"openalex":"https://openalex.org/W2907190532","doi":"https://doi.org/10.1109/icarcv.2018.8581339","mag":"2907190532"},"language":"en","primary_location":{"id":"doi:10.1109/icarcv.2018.8581339","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2018.8581339","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 15th International Conference on Control, Automation, Robotics and Vision (ICARCV)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028921173","display_name":"Bindu Sharan","orcid":null},"institutions":[{"id":"https://openalex.org/I9579091","display_name":"Indian Institute of Technology Mandi","ror":"https://ror.org/05r9r2f34","country_code":"IN","type":"education","lineage":["https://openalex.org/I9579091"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Bindu Sharan","raw_affiliation_strings":["School of Computing and Electrical Engineering, Indian Institute of Technology, Mandi, Himachal Pradesh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Computing and Electrical Engineering, Indian Institute of Technology, Mandi, Himachal Pradesh, India","institution_ids":["https://openalex.org/I9579091"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5010806251","display_name":"Tushar Jain","orcid":"https://orcid.org/0000-0003-2300-1375"},"institutions":[{"id":"https://openalex.org/I9579091","display_name":"Indian Institute of Technology Mandi","ror":"https://ror.org/05r9r2f34","country_code":"IN","type":"education","lineage":["https://openalex.org/I9579091"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Tushar Jain","raw_affiliation_strings":["School of Computing and Electrical Engineering, Indian Institute of Technology, Mandi, Himachal Pradesh, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Computing and Electrical Engineering, Indian Institute of Technology, Mandi, Himachal Pradesh, India","institution_ids":["https://openalex.org/I9579091"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.562,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.69798568,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7483921647071838},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7331297397613525},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7241522669792175},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.7034374475479126},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6480705738067627},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.6395424008369446},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.6023640632629395},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.500328779220581},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.48239362239837646},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4682546555995941},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.42220985889434814},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.394643098115921},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.22770434617996216},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.16002202033996582},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.09391051530838013},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.08560410141944885}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7483921647071838},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7331297397613525},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7241522669792175},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.7034374475479126},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6480705738067627},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.6395424008369446},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.6023640632629395},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.500328779220581},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.48239362239837646},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4682546555995941},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.42220985889434814},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.394643098115921},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.22770434617996216},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.16002202033996582},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09391051530838013},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.08560410141944885},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icarcv.2018.8581339","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2018.8581339","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 15th International Conference on Control, Automation, Robotics and Vision (ICARCV)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W252122814","https://openalex.org/W319207661","https://openalex.org/W1510598017","https://openalex.org/W1605077306","https://openalex.org/W1965346606","https://openalex.org/W1981481872","https://openalex.org/W1988499271","https://openalex.org/W2005749990","https://openalex.org/W2028755062","https://openalex.org/W2040049254","https://openalex.org/W2043046474","https://openalex.org/W2060903260","https://openalex.org/W2100636306","https://openalex.org/W2116499683","https://openalex.org/W2182730812","https://openalex.org/W2521269815","https://openalex.org/W2540383394","https://openalex.org/W2568491910","https://openalex.org/W2765113025","https://openalex.org/W2787197198","https://openalex.org/W4230460640","https://openalex.org/W6661221765"],"related_works":["https://openalex.org/W2560215812","https://openalex.org/W2949601986","https://openalex.org/W2788972299","https://openalex.org/W4385301753","https://openalex.org/W3186428265","https://openalex.org/W2171501125","https://openalex.org/W2617234683","https://openalex.org/W3121254296","https://openalex.org/W2060193301","https://openalex.org/W2375947351"],"abstract_inverted_index":{"Diagnosing":[0],"fault":[1,39,59],"at":[2],"early":[3],"stage":[4],"plays":[5],"a":[6,25,69,91],"significant":[7],"role":[8],"in":[9],"improving":[10],"the":[11,14,46,54,57,63],"reliability":[12],"of":[13,56,65,68,79,83],"wind":[15,93],"energy":[16],"conversion":[17],"systems":[18],"(WECS).":[19],"In":[20],"this":[21],"paper":[22],"we":[23],"present":[24],"method":[26,86],"to":[27],"diagnose":[28],"actuator":[29],"and":[30,41,76],"sensor":[31],"faults":[32],"based":[33,50],"on":[34,90],"unknown":[35,47,71],"input":[36,48,72,75],"observer.":[37],"The":[38,81],"detection":[40],"isolation":[42],"is":[43,60],"performed":[44],"using":[45],"observer":[49],"residual":[51],"generator":[52],"while":[53],"estimation":[55],"bias":[58],"accomplished":[61],"via":[62],"combination":[64],"estimated":[66],"states":[67],"specific":[70],"observer,":[73],"controlled":[74],"measured":[77],"variables":[78],"WECS.":[80],"effectiveness":[82],"an":[84],"aforesaid":[85],"has":[87],"been":[88],"simulated":[89],"2MW":[92],"turbine.":[94]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
