{"id":"https://openalex.org/W2898686600","doi":"https://doi.org/10.1109/etfa.2018.8502632","title":"Local Principal Component Analysis for Fault Detection in Air-Condensed Water Chillers","display_name":"Local Principal Component Analysis for Fault Detection in Air-Condensed Water Chillers","publication_year":2018,"publication_date":"2018-09-01","ids":{"openalex":"https://openalex.org/W2898686600","doi":"https://doi.org/10.1109/etfa.2018.8502632","mag":"2898686600"},"language":"en","primary_location":{"id":"doi:10.1109/etfa.2018.8502632","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa.2018.8502632","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 23rd International Conference on Emerging Technologies and Factory Automation (ETFA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084243839","display_name":"Francesco Simmini","orcid":"https://orcid.org/0000-0002-1210-1285"},"institutions":[{"id":"https://openalex.org/I138689650","display_name":"University of Padua","ror":"https://ror.org/00240q980","country_code":"IT","type":"education","lineage":["https://openalex.org/I138689650"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Francesco Simmini","raw_affiliation_strings":["Department of Information Engineering, University of Padova, Padova, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Information Engineering, University of Padova, Padova, Italy","institution_ids":["https://openalex.org/I138689650"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053243136","display_name":"Mirco Rampazzo","orcid":"https://orcid.org/0000-0003-0881-0131"},"institutions":[{"id":"https://openalex.org/I138689650","display_name":"University of Padua","ror":"https://ror.org/00240q980","country_code":"IT","type":"education","lineage":["https://openalex.org/I138689650"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Mirco Rampazzo","raw_affiliation_strings":["Department of Information Engineering, University of Padova, Padova, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Information Engineering, University of Padova, Padova, Italy","institution_ids":["https://openalex.org/I138689650"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043391732","display_name":"Alessandro Beghi","orcid":"https://orcid.org/0000-0003-2252-2179"},"institutions":[{"id":"https://openalex.org/I138689650","display_name":"University of Padua","ror":"https://ror.org/00240q980","country_code":"IT","type":"education","lineage":["https://openalex.org/I138689650"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Alessandro Beghi","raw_affiliation_strings":["Department of Information Engineering, University of Padova, Padova, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Information Engineering, University of Padova, Padova, Italy","institution_ids":["https://openalex.org/I138689650"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5012606772","display_name":"Fabio Peterle","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Fabio Peterle","raw_affiliation_strings":["Everest s.r.l., Pordenone, Italy"],"affiliations":[{"raw_affiliation_string":"Everest s.r.l., Pordenone, Italy","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5084243839"],"corresponding_institution_ids":["https://openalex.org/I138689650"],"apc_list":null,"apc_paid":null,"fwci":0.1872,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.52067065,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1322","last_page":"1327"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10640","display_name":"Spectroscopy and Chemometric Analyses","score":0.9794999957084656,"subfield":{"id":"https://openalex.org/subfields/1602","display_name":"Analytical Chemistry"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.968500018119812,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8022688627243042},{"id":"https://openalex.org/keywords/chiller","display_name":"Chiller","score":0.6968928575515747},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.6562175750732422},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.572219967842102},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5696045756340027},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5293442010879517},{"id":"https://openalex.org/keywords/principal-component-analysis","display_name":"Principal component analysis","score":0.5240293145179749},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4967844784259796},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.4455889165401459},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.4449102580547333},{"id":"https://openalex.org/keywords/exploit","display_name":"Exploit","score":0.4257134199142456},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.38214775919914246},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.23023909330368042}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8022688627243042},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.6968928575515747},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.6562175750732422},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.572219967842102},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5696045756340027},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5293442010879517},{"id":"https://openalex.org/C27438332","wikidata":"https://www.wikidata.org/wiki/Q2873","display_name":"Principal component analysis","level":2,"score":0.5240293145179749},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4967844784259796},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.4455889165401459},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.4449102580547333},{"id":"https://openalex.org/C165696696","wikidata":"https://www.wikidata.org/wiki/Q11287","display_name":"Exploit","level":2,"score":0.4257134199142456},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38214775919914246},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.23023909330368042},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/etfa.2018.8502632","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa.2018.8502632","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 23rd International Conference on Emerging Technologies and Factory Automation (ETFA)","raw_type":"proceedings-article"},{"id":"pmh:oai:www.research.unipd.it:11577/3283260","is_oa":false,"landing_page_url":"http://hdl.handle.net/11577/3283260","pdf_url":null,"source":{"id":"https://openalex.org/S4377196283","display_name":"Research Padua  Archive (University of Padua)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I138689650","host_organization_name":"University of Padua","host_organization_lineage":["https://openalex.org/I138689650"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W563702179","https://openalex.org/W1978677160","https://openalex.org/W2001062903","https://openalex.org/W2002268936","https://openalex.org/W2026597535","https://openalex.org/W2115950701","https://openalex.org/W2122646361","https://openalex.org/W2132029223","https://openalex.org/W2135663228","https://openalex.org/W2147129131","https://openalex.org/W2169347809","https://openalex.org/W2493627968","https://openalex.org/W2546067355"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W2900606913","https://openalex.org/W4320003279","https://openalex.org/W2333766344","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226","https://openalex.org/W2373424295","https://openalex.org/W2474947501"],"abstract_inverted_index":{"Water":[0],"chillers":[1,12],"play":[2],"a":[3,60,66,75,84,94,123],"crucial":[4],"role":[5],"in":[6,71,134],"HVAC":[7],"systems.":[8],"Faulty":[9],"operations":[10,111],"of":[11,29,55,83,115],"can":[13],"lead":[14],"to":[15,25,73,99,104,109,129],"energy":[16],"wastage,":[17],"system":[18],"unreliability":[19],"and":[20,38,44,103,137],"shorter":[21],"equipment":[22],"life.":[23],"Due":[24],"the":[26,53,116],"intrinsic":[27],"complexity":[28],"these":[30],"systems,":[31],"which":[32,126],"are":[33,46],"nonlinear":[34,101],"with":[35,107],"interrelated":[36],"parameters,":[37],"since":[39],"data":[40],"regarding":[41],"unforeseen":[42],"phenomena":[43],"abnormalities":[45],"not":[47],"usually":[48],"available":[49],"for":[50],"air-conditioning":[51],"installations,":[52],"development":[54],"fault":[56,76],"detection":[57,77],"algorithms":[58],"is":[59,69,119,127],"burdensome":[61],"task.":[62],"In":[63,90],"this":[64],"paper,":[65],"data-driven":[67],"approach":[68,118],"used":[70],"order":[72],"develop":[74],"methodology":[78],"that":[79],"makes":[80],"no":[81],"use":[82],"priori":[85],"knowledge":[86],"about":[87],"abnormal":[88],"phenomena.":[89],"particular,":[91],"we":[92],"exploit":[93],"local":[95],"Principal":[96],"Component":[97],"Analysis":[98],"handle":[100],"cases":[102],"accent":[105],"novelties":[106],"respect":[108],"non-faulty":[110],"variability.":[112],"The":[113],"performance":[114],"proposed":[117],"assessed":[120],"by":[121],"using":[122],"synthetic":[124],"dataset":[125],"related":[128],"an":[130],"air-condensed":[131],"water":[132],"chiller":[133],"both":[135],"fault-free":[136],"faulty":[138],"conditions.":[139]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
