{"id":"https://openalex.org/W2073875529","doi":"https://doi.org/10.1109/etfa.2012.6489609","title":"Multiregional PI control strategy for dissolved oxygen and aeration system control at biological wastewater treatment plant","display_name":"Multiregional PI control strategy for dissolved oxygen and aeration system control at biological wastewater treatment plant","publication_year":2012,"publication_date":"2012-09-01","ids":{"openalex":"https://openalex.org/W2073875529","doi":"https://doi.org/10.1109/etfa.2012.6489609","mag":"2073875529"},"language":"en","primary_location":{"id":"doi:10.1109/etfa.2012.6489609","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa.2012.6489609","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of 2012 IEEE 17th International Conference on Emerging Technologies &amp; Factory Automation (ETFA 2012)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090519297","display_name":"Robert Piotrowski","orcid":"https://orcid.org/0000-0002-0499-3463"},"institutions":[{"id":"https://openalex.org/I169333911","display_name":"Gda\u0144sk University of Technology","ror":"https://ror.org/006x4sc24","country_code":"PL","type":"education","lineage":["https://openalex.org/I169333911"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"R. Piotrowski","raw_affiliation_strings":["Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Gdansk, Poland","Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, Poland"],"affiliations":[{"raw_affiliation_string":"Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Gdansk, Poland","institution_ids":["https://openalex.org/I169333911"]},{"raw_affiliation_string":"Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, Poland","institution_ids":["https://openalex.org/I169333911"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072617492","display_name":"Adam Zawadzki","orcid":null},"institutions":[{"id":"https://openalex.org/I169333911","display_name":"Gda\u0144sk University of Technology","ror":"https://ror.org/006x4sc24","country_code":"PL","type":"education","lineage":["https://openalex.org/I169333911"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"A. Zawadzki","raw_affiliation_strings":["Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Gdansk, Poland","Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, Poland"],"affiliations":[{"raw_affiliation_string":"Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Gdansk, Poland","institution_ids":["https://openalex.org/I169333911"]},{"raw_affiliation_string":"Department of Control Systems Engineering, Electrical and Control Engineering Faculty, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, Poland","institution_ids":["https://openalex.org/I169333911"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5090519297"],"corresponding_institution_ids":["https://openalex.org/I169333911"],"apc_list":null,"apc_paid":null,"fwci":0.8356,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.7170279,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10564","display_name":"Wastewater Treatment and Nitrogen Removal","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2310","display_name":"Pollution"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10564","display_name":"Wastewater Treatment and Nitrogen Removal","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2310","display_name":"Pollution"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9843000173568726,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/aeration","display_name":"Aeration","score":0.7397534251213074},{"id":"https://openalex.org/keywords/sewage-treatment","display_name":"Sewage treatment","score":0.6446857452392578},{"id":"https://openalex.org/keywords/wastewater","display_name":"Wastewater","score":0.5523187518119812},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.46927371621131897},{"id":"https://openalex.org/keywords/fuzzy-control-system","display_name":"Fuzzy control system","score":0.44574087858200073},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.44347095489501953},{"id":"https://openalex.org/keywords/biochemical-oxygen-demand","display_name":"Biochemical oxygen demand","score":0.41750386357307434},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4114099144935608},{"id":"https://openalex.org/keywords/process-engineering","display_name":"Process engineering","score":0.39561909437179565},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.39385735988616943},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3849087655544281},{"id":"https://openalex.org/keywords/environmental-engineering","display_name":"Environmental engineering","score":0.3752721846103668},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3576733469963074},{"id":"https://openalex.org/keywords/chemical-oxygen-demand","display_name":"Chemical oxygen demand","score":0.33595287799835205},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3318249583244324},{"id":"https://openalex.org/keywords/waste-management","display_name":"Waste management","score":0.24112239480018616},{"id":"https://openalex.org/keywords/fuzzy-logic","display_name":"Fuzzy logic","score":0.22627583146095276},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.1184801459312439}],"concepts":[{"id":"https://openalex.org/C86922832","wikidata":"https://www.wikidata.org/wiki/Q381105","display_name":"Aeration","level":2,"score":0.7397534251213074},{"id":"https://openalex.org/C57442070","wikidata":"https://www.wikidata.org/wiki/Q221275","display_name":"Sewage treatment","level":2,"score":0.6446857452392578},{"id":"https://openalex.org/C94061648","wikidata":"https://www.wikidata.org/wiki/Q336191","display_name":"Wastewater","level":2,"score":0.5523187518119812},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.46927371621131897},{"id":"https://openalex.org/C195975749","wikidata":"https://www.wikidata.org/wiki/Q1475705","display_name":"Fuzzy control system","level":3,"score":0.44574087858200073},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.44347095489501953},{"id":"https://openalex.org/C198302294","wikidata":"https://www.wikidata.org/wiki/Q215624","display_name":"Biochemical oxygen demand","level":4,"score":0.41750386357307434},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4114099144935608},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.39561909437179565},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.39385735988616943},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3849087655544281},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.3752721846103668},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3576733469963074},{"id":"https://openalex.org/C188287460","wikidata":"https://www.wikidata.org/wiki/Q555857","display_name":"Chemical oxygen demand","level":3,"score":0.33595287799835205},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3318249583244324},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.24112239480018616},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.22627583146095276},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1184801459312439},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/etfa.2012.6489609","is_oa":false,"landing_page_url":"https://doi.org/10.1109/etfa.2012.6489609","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of 2012 IEEE 17th International Conference on Emerging Technologies &amp; Factory Automation (ETFA 2012)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation","score":0.8700000047683716}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W215901610","https://openalex.org/W1182707377","https://openalex.org/W1736934387","https://openalex.org/W1969631053","https://openalex.org/W1975614974","https://openalex.org/W1977526056","https://openalex.org/W1989555277","https://openalex.org/W2003804629","https://openalex.org/W2006352352","https://openalex.org/W2010528911","https://openalex.org/W2012370565","https://openalex.org/W2038517185","https://openalex.org/W2083843630","https://openalex.org/W2087409001","https://openalex.org/W2114474225","https://openalex.org/W2129682765","https://openalex.org/W2139133559","https://openalex.org/W2170265683","https://openalex.org/W2171702390","https://openalex.org/W3206327493","https://openalex.org/W4234158872","https://openalex.org/W6628019238","https://openalex.org/W6643756426","https://openalex.org/W6652945198"],"related_works":["https://openalex.org/W2347757946","https://openalex.org/W3207864831","https://openalex.org/W2138542115","https://openalex.org/W2116493921","https://openalex.org/W2368853056","https://openalex.org/W167936449","https://openalex.org/W2887738246","https://openalex.org/W2034367512","https://openalex.org/W2350363074","https://openalex.org/W160042994"],"abstract_inverted_index":{"The":[0,14,31,44,53,72],"dissolved":[1,15,40],"oxygen":[2,16,41],"is":[3,19,47,61,76,87,101],"a":[4,34],"key":[5],"parameter":[6],"for":[7,39],"biological":[8,29,90],"processes":[9],"at":[10,94],"wastewater":[11,91],"treatment":[12,92],"plant.":[13],"tracking":[17,42],"problem":[18],"one":[20],"of":[21,28,70],"the":[22,57,67,82],"most":[23],"complex":[24],"and":[25,78,100],"fundamental":[26],"issue":[27],"processes.":[30],"paper":[32],"proposes":[33],"new":[35],"multiregional":[36],"control":[37,51,54,74],"strategy":[38,75],"problem.":[43],"aeration":[45],"system":[46],"included":[48],"in":[49],"overall":[50],"structure.":[52],"mechanism":[55],"within":[56],"operating":[58],"point":[59],"area":[60],"based":[62,80],"on":[63,81],"PI":[64],"controllers":[65],"with":[66],"Takagi-Sugeno-Kang":[68],"method":[69],"defuzzification.":[71],"proposed":[73],"designed":[77],"tested":[79],"real":[83],"data":[84],"records.":[85],"It":[86],"applied":[88],"to":[89],"plant":[93],"Nowy":[95],"Dwor":[96],"Gdanski,":[97],"Northern":[98],"Poland":[99],"validated":[102],"by":[103],"simulation.":[104]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
