{"id":"https://openalex.org/W2099487458","doi":"https://doi.org/10.1109/efta.2007.4416748","title":"Limits of increasing the performance of Industrial Ethernet protocols","display_name":"Limits of increasing the performance of Industrial Ethernet protocols","publication_year":2007,"publication_date":"2007-09-01","ids":{"openalex":"https://openalex.org/W2099487458","doi":"https://doi.org/10.1109/efta.2007.4416748","mag":"2099487458"},"language":"en","primary_location":{"id":"doi:10.1109/efta.2007.4416748","is_oa":false,"landing_page_url":"https://doi.org/10.1109/efta.2007.4416748","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 IEEE Conference on Emerging Technologies &amp; Factory Automation (EFTA 2007)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5025905769","display_name":"J\u00fcrgen Jasperneite","orcid":"https://orcid.org/0000-0001-7962-2491"},"institutions":[{"id":"https://openalex.org/I5209920","display_name":"Ostwestfalen-Lippe University of Applied Sciences and Arts","ror":"https://ror.org/04eka8j06","country_code":"DE","type":"education","lineage":["https://openalex.org/I5209920"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Juergen Jasperneite","raw_affiliation_strings":["InIT-Institute Industrial IT, LuH University of Applied Sciences, Lemgo, Germany","LuH Univ. of Appl. Sci., Lemgo"],"affiliations":[{"raw_affiliation_string":"InIT-Institute Industrial IT, LuH University of Applied Sciences, Lemgo, Germany","institution_ids":["https://openalex.org/I5209920"]},{"raw_affiliation_string":"LuH Univ. of Appl. Sci., Lemgo","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079135958","display_name":"Markus Schumacher","orcid":"https://orcid.org/0000-0002-4329-4446"},"institutions":[{"id":"https://openalex.org/I5209920","display_name":"Ostwestfalen-Lippe University of Applied Sciences and Arts","ror":"https://ror.org/04eka8j06","country_code":"DE","type":"education","lineage":["https://openalex.org/I5209920"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Markus Schumacher","raw_affiliation_strings":["InIT-Institute Industrial IT, LuH University of Applied Sciences, Lemgo, Germany","LuH Univ. of Appl. Sci., Lemgo"],"affiliations":[{"raw_affiliation_string":"InIT-Institute Industrial IT, LuH University of Applied Sciences, Lemgo, Germany","institution_ids":["https://openalex.org/I5209920"]},{"raw_affiliation_string":"LuH Univ. of Appl. Sci., Lemgo","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5033805944","display_name":"Karl Weber","orcid":null},"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Karl Weber","raw_affiliation_strings":["Automation & Drives, Siemens AG, Erlangen, Germany","Automation & Drives, Siemens AG D-91056 Erlangen, Germany"],"affiliations":[{"raw_affiliation_string":"Automation & Drives, Siemens AG, Erlangen, Germany","institution_ids":["https://openalex.org/I1325886976"]},{"raw_affiliation_string":"Automation & Drives, Siemens AG D-91056 Erlangen, Germany","institution_ids":["https://openalex.org/I1325886976"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5025905769"],"corresponding_institution_ids":["https://openalex.org/I5209920"],"apc_list":null,"apc_paid":null,"fwci":5.134,"has_fulltext":false,"cited_by_count":107,"citation_normalized_percentile":{"value":0.95535949,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":93,"max":100},"biblio":{"volume":null,"issue":null,"first_page":"17","last_page":"24"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10933","display_name":"Real-Time Systems Scheduling","score":0.963699996471405,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11125","display_name":"Petri Nets in System Modeling","score":0.9387999773025513,"subfield":{"id":"https://openalex.org/subfields/1703","display_name":"Computational Theory and Mathematics"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/industrial-ethernet","display_name":"Industrial Ethernet","score":0.932956337928772},{"id":"https://openalex.org/keywords/carrier-ethernet","display_name":"Carrier Ethernet","score":0.8668500185012817},{"id":"https://openalex.org/keywords/connection-oriented-ethernet","display_name":"Connection-oriented Ethernet","score":0.8658638000488281},{"id":"https://openalex.org/keywords/ethernet-over-sdh","display_name":"Ethernet over SDH","score":0.8590660095214844},{"id":"https://openalex.org/keywords/metro-ethernet","display_name":"Metro Ethernet","score":0.8389730453491211},{"id":"https://openalex.org/keywords/synchronous-ethernet","display_name":"Synchronous Ethernet","score":0.808092474937439},{"id":"https://openalex.org/keywords/ethernet-over-pdh","display_name":"Ethernet over PDH","score":0.7948707342147827},{"id":"https://openalex.org/keywords/ethernet-powerlink","display_name":"Ethernet Powerlink","score":0.7703367471694946},{"id":"https://openalex.org/keywords/ata-over-ethernet","display_name":"ATA over Ethernet","score":0.7458351850509644},{"id":"https://openalex.org/keywords/gigabit-ethernet","display_name":"Gigabit Ethernet","score":0.6500332355499268},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.6398775577545166},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5947864055633545},{"id":"https://openalex.org/keywords/ethernet-flow-control","display_name":"Ethernet flow control","score":0.4247652292251587},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.42276573181152344},{"id":"https://openalex.org/keywords/local-area-network","display_name":"Local area network","score":0.37185388803482056},{"id":"https://openalex.org/keywords/ethernet","display_name":"Ethernet","score":0.35156846046447754}],"concepts":[{"id":"https://openalex.org/C167151114","wikidata":"https://www.wikidata.org/wiki/Q1661930","display_name":"Industrial Ethernet","level":3,"score":0.932956337928772},{"id":"https://openalex.org/C151898751","wikidata":"https://www.wikidata.org/wiki/Q5046350","display_name":"Carrier Ethernet","level":3,"score":0.8668500185012817},{"id":"https://openalex.org/C186844356","wikidata":"https://www.wikidata.org/wiki/Q5161679","display_name":"Connection-oriented Ethernet","level":4,"score":0.8658638000488281},{"id":"https://openalex.org/C30188135","wikidata":"https://www.wikidata.org/wiki/Q1118613","display_name":"Ethernet over SDH","level":4,"score":0.8590660095214844},{"id":"https://openalex.org/C151643298","wikidata":"https://www.wikidata.org/wiki/Q3050434","display_name":"Metro Ethernet","level":4,"score":0.8389730453491211},{"id":"https://openalex.org/C205215620","wikidata":"https://www.wikidata.org/wiki/Q7662206","display_name":"Synchronous Ethernet","level":3,"score":0.808092474937439},{"id":"https://openalex.org/C195801177","wikidata":"https://www.wikidata.org/wiki/Q5403360","display_name":"Ethernet over PDH","level":5,"score":0.7948707342147827},{"id":"https://openalex.org/C70205395","wikidata":"https://www.wikidata.org/wiki/Q1371218","display_name":"Ethernet Powerlink","level":5,"score":0.7703367471694946},{"id":"https://openalex.org/C60665866","wikidata":"https://www.wikidata.org/wiki/Q298746","display_name":"ATA over Ethernet","level":4,"score":0.7458351850509644},{"id":"https://openalex.org/C2776379158","wikidata":"https://www.wikidata.org/wiki/Q1069084","display_name":"Gigabit Ethernet","level":3,"score":0.6500332355499268},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6398775577545166},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5947864055633545},{"id":"https://openalex.org/C68178114","wikidata":"https://www.wikidata.org/wiki/Q5403359","display_name":"Ethernet flow control","level":3,"score":0.4247652292251587},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.42276573181152344},{"id":"https://openalex.org/C137471899","wikidata":"https://www.wikidata.org/wiki/Q11381","display_name":"Local area network","level":2,"score":0.37185388803482056},{"id":"https://openalex.org/C172173386","wikidata":"https://www.wikidata.org/wiki/Q79984","display_name":"Ethernet","level":2,"score":0.35156846046447754}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/efta.2007.4416748","is_oa":false,"landing_page_url":"https://doi.org/10.1109/efta.2007.4416748","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 IEEE Conference on Emerging Technologies &amp; Factory Automation (EFTA 2007)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6000000238418579,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W99161498","https://openalex.org/W1585636656","https://openalex.org/W2026640816","https://openalex.org/W2167757118","https://openalex.org/W2167830511"],"related_works":["https://openalex.org/W1510867147","https://openalex.org/W4205938724","https://openalex.org/W2355513764","https://openalex.org/W2461431827","https://openalex.org/W2033261855","https://openalex.org/W2794242809","https://openalex.org/W2114838953","https://openalex.org/W28929208","https://openalex.org/W3080198137","https://openalex.org/W2016072001"],"abstract_inverted_index":{"The":[0,55,96],"evolution":[1],"of":[2,28,67,82,109],"industrial":[3,68,87],"communication":[4],"inexorably":[5],"moves":[6],"to":[7,22,34,40,48,51,78],"Industrial":[8,115],"Ethernet":[9,16,47,50,116],"networks.":[10,117],"One":[11],"important":[12],"reason":[13],"for":[14,85,112],"using":[15],"at":[17],"the":[18,25,36,42,59,75,86],"shop":[19],"floor":[20],"is":[21,98],"participate":[23],"on":[24,93,100],"continuous":[26],"advancements":[27],"standard":[29],"Ethernet.":[30],"Thus":[31],"it":[32],"seems":[33],"be":[35],"logical":[37],"next":[38],"step":[39],"change":[41],"bit":[43,76],"rate":[44,77],"from":[45,73],"Fast":[46],"Gigabit":[49],"achieve":[52],"better":[53],"performance.":[54],"question":[56],"is,":[57],"how":[58],"cycle":[60],"time":[61],"as":[62],"a":[63],"relevant":[64],"performance":[65,114],"metrics":[66],"automation":[69,88],"systems":[70],"can":[71],"profit":[72],"increasing":[74],"1":[79],"Gbps.":[80],"Because":[81],"its":[83],"importance":[84],"domain":[89],"this":[90],"paper":[91],"focuses":[92],"line":[94],"topology.":[95],"analysis":[97],"based":[99],"EtherCAT":[101],"and":[102],"PROFINET,":[103],"which":[104],"are":[105],"two":[106],"popular":[107],"representatives":[108],"different":[110],"architectures":[111],"high":[113]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":9},{"year":2017,"cited_by_count":11},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":8},{"year":2014,"cited_by_count":16},{"year":2013,"cited_by_count":15},{"year":2012,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
