{"id":"https://openalex.org/W1979565799","doi":"https://doi.org/10.1109/dft.2012.6378228","title":"A novel pseudonoise tester for transmission line fault location and identification using pseudorandom binary sequences","display_name":"A novel pseudonoise tester for transmission line fault location and identification using pseudorandom binary sequences","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W1979565799","doi":"https://doi.org/10.1109/dft.2012.6378228","mag":"1979565799"},"language":"en","primary_location":{"id":"doi:10.1109/dft.2012.6378228","is_oa":false,"landing_page_url":"https://doi.org/10.1109/dft.2012.6378228","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Symposium on Defect and Fault Tolerance in VLSI and Nanotechnology Systems (DFT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5058238820","display_name":"R.A. Guinee","orcid":null},"institutions":[{"id":"https://openalex.org/I4210100923","display_name":"Munster Technological University","ror":"https://ror.org/013xpqh61","country_code":"IE","type":"facility","lineage":["https://openalex.org/I4210100923"]}],"countries":["IE"],"is_corresponding":true,"raw_author_name":"Richard A. Guinee","raw_affiliation_strings":["Cork Institute of Technology, Cork, Ireland","Cork Institute of Technology , Cork , Ireland"],"affiliations":[{"raw_affiliation_string":"Cork Institute of Technology, Cork, Ireland","institution_ids":["https://openalex.org/I4210100923"]},{"raw_affiliation_string":"Cork Institute of Technology , Cork , Ireland","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5058238820"],"corresponding_institution_ids":["https://openalex.org/I4210100923"],"apc_list":null,"apc_paid":null,"fwci":0.491,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.66525065,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"225","last_page":"232"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14117","display_name":"Integrated Circuits and Semiconductor Failure Analysis","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14117","display_name":"Integrated Circuits and Semiconductor Failure Analysis","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11609","display_name":"Geophysical Methods and Applications","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pseudorandom-binary-sequence","display_name":"Pseudorandom binary sequence","score":0.7966108322143555},{"id":"https://openalex.org/keywords/pseudorandom-noise","display_name":"Pseudorandom noise","score":0.597902774810791},{"id":"https://openalex.org/keywords/pseudorandom-number-generator","display_name":"Pseudorandom number generator","score":0.5848351120948792},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5800054669380188},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.5279620885848999},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.519531786441803},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5041979551315308},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.49800586700439453},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.490313321352005},{"id":"https://openalex.org/keywords/fault-coverage","display_name":"Fault coverage","score":0.48910242319107056},{"id":"https://openalex.org/keywords/stuck-at-fault","display_name":"Stuck-at fault","score":0.45312926173210144},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4519009292125702},{"id":"https://openalex.org/keywords/time-domain","display_name":"Time domain","score":0.43153226375579834},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3735783100128174},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.32636409997940063},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2409798502922058},{"id":"https://openalex.org/keywords/binary-number","display_name":"Binary number","score":0.19771131873130798},{"id":"https://openalex.org/keywords/spread-spectrum","display_name":"Spread spectrum","score":0.12562108039855957},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.11951145529747009},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.07960274815559387}],"concepts":[{"id":"https://openalex.org/C128040838","wikidata":"https://www.wikidata.org/wiki/Q1810628","display_name":"Pseudorandom binary sequence","level":3,"score":0.7966108322143555},{"id":"https://openalex.org/C151881341","wikidata":"https://www.wikidata.org/wiki/Q910571","display_name":"Pseudorandom noise","level":4,"score":0.597902774810791},{"id":"https://openalex.org/C140642157","wikidata":"https://www.wikidata.org/wiki/Q1623338","display_name":"Pseudorandom number generator","level":2,"score":0.5848351120948792},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5800054669380188},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5279620885848999},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.519531786441803},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5041979551315308},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.49800586700439453},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.490313321352005},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.48910242319107056},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.45312926173210144},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4519009292125702},{"id":"https://openalex.org/C103824480","wikidata":"https://www.wikidata.org/wiki/Q185889","display_name":"Time domain","level":2,"score":0.43153226375579834},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3735783100128174},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.32636409997940063},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2409798502922058},{"id":"https://openalex.org/C48372109","wikidata":"https://www.wikidata.org/wiki/Q3913","display_name":"Binary number","level":2,"score":0.19771131873130798},{"id":"https://openalex.org/C105344744","wikidata":"https://www.wikidata.org/wiki/Q958957","display_name":"Spread spectrum","level":3,"score":0.12562108039855957},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11951145529747009},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.07960274815559387},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0},{"id":"https://openalex.org/C47696715","wikidata":"https://www.wikidata.org/wiki/Q233394","display_name":"Code division multiple access","level":2,"score":0.0},{"id":"https://openalex.org/C94375191","wikidata":"https://www.wikidata.org/wiki/Q11205","display_name":"Arithmetic","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/dft.2012.6378228","is_oa":false,"landing_page_url":"https://doi.org/10.1109/dft.2012.6378228","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Symposium on Defect and Fault Tolerance in VLSI and Nanotechnology Systems (DFT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1589394642","https://openalex.org/W2146158110","https://openalex.org/W2150814805","https://openalex.org/W2157535081","https://openalex.org/W2181457765","https://openalex.org/W2609301862"],"related_works":["https://openalex.org/W2168932789","https://openalex.org/W2348496033","https://openalex.org/W2359988188","https://openalex.org/W2377703742","https://openalex.org/W940111385","https://openalex.org/W3150014313","https://openalex.org/W1971307907","https://openalex.org/W2019938427","https://openalex.org/W2666077296","https://openalex.org/W4399186697"],"abstract_inverted_index":{"A":[0],"novel":[1],"pulse":[2],"echo":[3,42,277],"test":[4,48,75,210,220,351],"methodology,":[5],"using":[6,246],"PRBS":[7,47,209],"excitation,":[8],"is":[9,34,164,295],"presented":[10,165,224],"in":[11,52,84,101,187,212,312,334,348],"this":[12,32,155],"paper":[13,156],"as":[14,66,68,323],"an":[15,118],"alternative":[16],"to":[17,136,182],"Time":[18],"Domain":[19],"Reflectometry":[20],"(TDR)":[21],"for":[22,56,111,145,166,189,195,225,275,285],"transmission":[23,96,161,167,264,313],"line":[24,162,168,314],"fault":[25,41,57,79,123,149,184,198,213,242,251,272,306,327],"location":[26,80,151,245],"and":[27,98,141,152,216,244,309,330,344],"identification.":[28,153],"The":[29,290],"essence":[30],"of":[31,39,74,87,148,191,207,237,241,249,257,292,343],"scheme":[33],"the":[35,40,45,72,146,205,208,235,255,270,293,341,349],"cross":[36],"correlation":[37,261],"(CCR)":[38],"response":[43,203,278],"with":[44,171,200,262,281,337],"input":[46],"perturbation":[49],"which":[50,104,233,268,332],"results":[51,221],"a":[53,85,107,157,226,247,282],"unique":[54],"signature":[55],"type":[58,214],"identification,":[59],"if":[60],"any,":[61],"or":[62,114],"load":[63,180],"termination":[64,328],"present":[65],"well":[67],"its":[69],"distance":[70],"from":[71,319],"point":[73],"stimulus":[76,176],"injection.":[77],"This":[78],"technique":[81],"can":[82,125],"used":[83],"number":[86],"key":[88],"industrial":[89],"applications":[90],"incorporating":[91],"printed":[92],"circuit":[93],"boards,":[94],"overhead":[95],"lines":[97],"underground":[99],"cables":[100],"inaccessible":[102],"locations":[103],"rely":[105],"on":[106],"metallic":[108],"conductor":[109],"pathway":[110],"power":[112],"transfer":[113],"signal":[115,139],"propagation.":[116],"As":[117],"improved":[119,276],"method":[120,211,240,294],"pseudonoise":[121],"(PN)":[122],"identification":[124,215],"be":[126],"performed":[127],"over":[128],"several":[129],"cycles":[130],"at":[131],"low":[132],"amplitude":[133],"levels":[134],"online":[135],"reject":[137],"normal":[138],"traffic":[140],"extraneous":[142],"noise":[143,266],"pickup":[144],"purpose":[147],"coverage":[150],"In":[154],"high":[158],"frequency":[159],"co-axial":[160,227,303],"model":[163],"behavioural":[169],"simulation":[170],"pseudorandom":[172],"binary":[173],"sequence":[174],"(PRBS)":[175],"injection":[177],"under":[178,229],"known":[179,196,302],"terminations":[181,308],"mimic":[183],"conditions":[185],"encountered":[186],"practice":[188],"proof":[190],"concept.":[192],"Simulation":[193],"results,":[194],"resistive":[197,250],"terminations,":[199],"measured":[201],"CCR":[202],"demonstrate":[204,340],"effectiveness":[206,256],"location.":[217],"Key":[218],"experimental":[219,315,320],"are":[222,287,333],"also":[223,288],"cable,":[228],"laboratory":[230],"controlled":[231],"conditions,":[232],"substantiates":[234],"accuracy":[236,291,342],"PRBS-CCR":[238],"diagnostic":[239],"recognition":[243],"range":[248],"terminations.":[252],"Results":[253],"demonstrating":[254],"multiple":[258],"PN":[259,350],"cycle":[260],"inherent":[263],"link":[265,310],"rejection,":[267],"accentuates":[269],"peak":[271],"CCR-to-noise":[273],"ratio,":[274],"resolution":[279],"along":[280],"theoretical":[283,299,338],"analysis":[284],"same":[286],"presented.":[289],"further":[296,345],"validated":[297],"through":[298],"calculations":[300],"via":[301],"cable":[304],"parameters,":[305],"resistance":[307],"distances":[311],"testing.":[316],"Derived":[317],"quantities":[318],"testing":[321],"such":[322],"estimated":[324],"reflection":[325],"coefficients,":[326],"resistances":[329],"VSWR,":[331],"close":[335],"agreement":[336],"considerations,":[339],"enhance":[346],"confidence":[347],"method.":[352]},"counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
