{"id":"https://openalex.org/W3001347619","doi":"https://doi.org/10.1109/cisp-bmei48845.2019.8965959","title":"Design and Implementation of the Performance Test of Our Self-developed Bowel Sound Recorder","display_name":"Design and Implementation of the Performance Test of Our Self-developed Bowel Sound Recorder","publication_year":2019,"publication_date":"2019-10-01","ids":{"openalex":"https://openalex.org/W3001347619","doi":"https://doi.org/10.1109/cisp-bmei48845.2019.8965959","mag":"3001347619"},"language":"en","primary_location":{"id":"doi:10.1109/cisp-bmei48845.2019.8965959","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cisp-bmei48845.2019.8965959","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 12th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101461675","display_name":"Guojing Wang","orcid":"https://orcid.org/0000-0002-5489-2118"},"institutions":[{"id":"https://openalex.org/I4210160531","display_name":"Chinese People's Liberation Army","ror":"https://ror.org/05tf9r976","country_code":"CN","type":"funder","lineage":["https://openalex.org/I4210160531"]},{"id":"https://openalex.org/I4210101382","display_name":"People's Liberation Army No. 150 Hospital","ror":"https://ror.org/014nsap67","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210101382"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Guojing Wang","raw_affiliation_strings":["Department of Biomedical Engineering, Chinese People's Liberation Army General Hospital, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Chinese People's Liberation Army General Hospital, Beijing, China","institution_ids":["https://openalex.org/I4210101382","https://openalex.org/I4210160531"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100432941","display_name":"Weidong Wang","orcid":"https://orcid.org/0000-0002-9553-0674"},"institutions":[{"id":"https://openalex.org/I4210160531","display_name":"Chinese People's Liberation Army","ror":"https://ror.org/05tf9r976","country_code":"CN","type":"funder","lineage":["https://openalex.org/I4210160531"]},{"id":"https://openalex.org/I4210101382","display_name":"People's Liberation Army No. 150 Hospital","ror":"https://ror.org/014nsap67","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210101382"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Weidong Wang","raw_affiliation_strings":["Department of Biomedical Engineering, Chinese People's Liberation Army General Hospital, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Chinese People's Liberation Army General Hospital, Beijing, China","institution_ids":["https://openalex.org/I4210101382","https://openalex.org/I4210160531"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100623849","display_name":"Hongyun Liu","orcid":"https://orcid.org/0000-0002-3472-9102"},"institutions":[{"id":"https://openalex.org/I4210101382","display_name":"People's Liberation Army No. 150 Hospital","ror":"https://ror.org/014nsap67","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210101382"]},{"id":"https://openalex.org/I4210160531","display_name":"Chinese People's Liberation Army","ror":"https://ror.org/05tf9r976","country_code":"CN","type":"funder","lineage":["https://openalex.org/I4210160531"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongyun Liu","raw_affiliation_strings":["Department of Biomedical Engineering, Chinese People's Liberation Army General Hospital, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Chinese People's Liberation Army General Hospital, Beijing, China","institution_ids":["https://openalex.org/I4210101382","https://openalex.org/I4210160531"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5101461675"],"corresponding_institution_ids":["https://openalex.org/I4210101382","https://openalex.org/I4210160531"],"apc_list":null,"apc_paid":null,"fwci":0.3458,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.67683881,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12419","display_name":"Phonocardiography and Auscultation Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T12419","display_name":"Phonocardiography and Auscultation Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11692","display_name":"Noise Effects and Management","score":0.9523000121116638,"subfield":{"id":"https://openalex.org/subfields/3616","display_name":"Speech and Hearing"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11768","display_name":"Music Therapy and Health","score":0.9061999917030334,"subfield":{"id":"https://openalex.org/subfields/3207","display_name":"Social Psychology"},"field":{"id":"https://openalex.org/fields/32","display_name":"Psychology"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sound","display_name":"Sound (geography)","score":0.6708508729934692},{"id":"https://openalex.org/keywords/sound-level-meter","display_name":"Sound level meter","score":0.6494001150131226},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5365713834762573},{"id":"https://openalex.org/keywords/metre","display_name":"Metre","score":0.453460156917572},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.44102779030799866},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4301705062389374},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.412007212638855},{"id":"https://openalex.org/keywords/sound-pressure","display_name":"Sound pressure","score":0.19813022017478943},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.12780532240867615},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.09754887223243713},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.09204965829849243},{"id":"https://openalex.org/keywords/noise-level","display_name":"Noise level","score":0.06558966636657715}],"concepts":[{"id":"https://openalex.org/C203718221","wikidata":"https://www.wikidata.org/wiki/Q491713","display_name":"Sound (geography)","level":2,"score":0.6708508729934692},{"id":"https://openalex.org/C2778554111","wikidata":"https://www.wikidata.org/wiki/Q1140661","display_name":"Sound level meter","level":4,"score":0.6494001150131226},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5365713834762573},{"id":"https://openalex.org/C151011524","wikidata":"https://www.wikidata.org/wiki/Q11573","display_name":"Metre","level":2,"score":0.453460156917572},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.44102779030799866},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4301705062389374},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.412007212638855},{"id":"https://openalex.org/C68115822","wikidata":"https://www.wikidata.org/wiki/Q1068172","display_name":"Sound pressure","level":2,"score":0.19813022017478943},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12780532240867615},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.09754887223243713},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09204965829849243},{"id":"https://openalex.org/C2984485829","wikidata":"https://www.wikidata.org/wiki/Q100766421","display_name":"Noise level","level":3,"score":0.06558966636657715},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cisp-bmei48845.2019.8965959","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cisp-bmei48845.2019.8965959","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 12th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2010708019","https://openalex.org/W2072145274","https://openalex.org/W2085171379","https://openalex.org/W2090566395","https://openalex.org/W2239601493","https://openalex.org/W2371679210","https://openalex.org/W2417343235","https://openalex.org/W2545985937","https://openalex.org/W2595299412","https://openalex.org/W2735306601","https://openalex.org/W2808868509","https://openalex.org/W3024154668"],"related_works":["https://openalex.org/W2085330189","https://openalex.org/W2867472389","https://openalex.org/W2816761076","https://openalex.org/W2846085952","https://openalex.org/W2243789853","https://openalex.org/W1998241616","https://openalex.org/W3119138318","https://openalex.org/W2193638554","https://openalex.org/W2049148912","https://openalex.org/W2047486612","https://openalex.org/W2837563230","https://openalex.org/W2758437781","https://openalex.org/W2918233391","https://openalex.org/W1555367488","https://openalex.org/W2024367268","https://openalex.org/W2414210569","https://openalex.org/W1953717417","https://openalex.org/W2818006564"],"abstract_inverted_index":{"Bowel":[0],"sound":[1,51,70,85,100,115,118,130,134,159],"is":[2,19,36,121,137,176],"one":[3],"of":[4,9,15,82,97,108,157,172,177,185],"the":[5,13,31,42,48,62,68,74,79,93,98,106,109,113,124,128,133,150,153,169,182],"important":[6],"physiological":[7],"signals":[8],"human":[10],"body":[11],"and":[12,17,21,34,66,117,132,139,155,175],"research":[14],"detecting":[16],"analyzing":[18],"increasing":[20],"deepening.":[22],"However,":[23],"there":[24,35],"are":[25,161],"few":[26],"special":[27,49,63],"electronic":[28,44],"devices":[29],"for":[30,41,47,146,168,181],"bowel":[32,50,84,99,114,129,158,186],"sound,":[33],"almost":[37],"no":[38],"performance":[39,80],"test":[40,88,110],"corresponding":[43],"devices.":[45],"As":[46],"recorder":[52,101,116,131,160],"developed":[53],"by":[54],"ourselves,":[55],"this":[56,140],"paper":[57],"carried":[58],"out":[59],"tests":[60],"in":[61],"audiometry":[64],"room,":[65],"used":[67],"first-level":[69],"level":[71,119,135],"meter":[72,120,136],"as":[73],"standard":[75],"instrument":[76],"to":[77],"determine":[78],"parameters":[81],"our":[83],"recorder.":[86],"The":[87],"results":[89,111],"showed":[90],"that":[91],"(1)":[92],"upper":[94],"range":[95],"value":[96],"can":[102],"reach":[103],"100dB;":[104],"(2)":[105],"trend":[107],"between":[112,127],"consistent;":[122],"(3)":[123],"maximum":[125],"deviation":[126],"10dB,":[138],"result":[141],"provides":[142],"a":[143,165],"theoretical":[144],"basis":[145],"subsequent":[147,170],"calibration.":[148],"Through":[149],"quantitative":[151],"testing,":[152],"validity":[154],"reliability":[156],"determined,":[162],"which":[163],"lays":[164],"hardware":[166],"foundation":[167],"collection":[171],"clinical":[173,179],"data":[174],"great":[178],"significance":[180],"effective":[183],"acquisition":[184],"sounds.":[187]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
