{"id":"https://openalex.org/W2912112761","doi":"https://doi.org/10.1109/cisp-bmei.2018.8633049","title":"A Cost Effective Positioning Device in MRI-PHIFU System","display_name":"A Cost Effective Positioning Device in MRI-PHIFU System","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2912112761","doi":"https://doi.org/10.1109/cisp-bmei.2018.8633049","mag":"2912112761"},"language":"en","primary_location":{"id":"doi:10.1109/cisp-bmei.2018.8633049","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cisp-bmei.2018.8633049","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 11th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081184208","display_name":"Depeng Liu","orcid":"https://orcid.org/0000-0002-7555-3393"},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Depeng Liu","raw_affiliation_strings":["Biomedical Instrument Institute, Shanghai Jiao Tong University Shanghai China"],"affiliations":[{"raw_affiliation_string":"Biomedical Instrument Institute, Shanghai Jiao Tong University Shanghai China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019734665","display_name":"Guofeng Shen","orcid":"https://orcid.org/0000-0002-7731-5399"},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guofeng Shen","raw_affiliation_strings":["Biomedical Instrument Institute, Shanghai Jiao Tong University Shanghai China"],"affiliations":[{"raw_affiliation_string":"Biomedical Instrument Institute, Shanghai Jiao Tong University Shanghai China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100673573","display_name":"Shan Qiao","orcid":"https://orcid.org/0000-0003-3816-3414"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shan Qiao","raw_affiliation_strings":["Shanghai Shende Medical Technology Co., Ltd, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Shanghai Shende Medical Technology Co., Ltd, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082947407","display_name":"Zhiqiang Su","orcid":"https://orcid.org/0000-0001-7880-5034"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhiqiang Su","raw_affiliation_strings":["Shanghai Shende Medical Technology Co., Ltd, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Shanghai Shende Medical Technology Co., Ltd, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100428683","display_name":"Wenjie Liu","orcid":"https://orcid.org/0000-0002-9317-2869"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wenjie Liu","raw_affiliation_strings":["Shanghai Shende Medical Technology Co., Ltd, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Shanghai Shende Medical Technology Co., Ltd, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100712809","display_name":"Zhong\u2010Qiu Li","orcid":"https://orcid.org/0000-0003-3827-3402"},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhongqiu Li","raw_affiliation_strings":["Biomedical Instrument Institute, Shanghai Jiao Tong University Shanghai China"],"affiliations":[{"raw_affiliation_string":"Biomedical Instrument Institute, Shanghai Jiao Tong University Shanghai China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101047957","display_name":"Jiabao Wen","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jiabao Wen","raw_affiliation_strings":["Shanghai Shende Medical Technology Co., Ltd, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Shanghai Shende Medical Technology Co., Ltd, Shanghai, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109507436","display_name":"Jian Tao","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jian Tao","raw_affiliation_strings":["Shanghai Shende Medical Technology Co., Ltd, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Shanghai Shende Medical Technology Co., Ltd, Shanghai, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":8,"corresponding_author_ids":["https://openalex.org/A5081184208"],"corresponding_institution_ids":["https://openalex.org/I183067930"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.17021367,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10958","display_name":"Ultrasound and Hyperthermia Applications","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10958","display_name":"Ultrasound and Hyperthermia Applications","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10727","display_name":"Ultrasound Imaging and Elastography","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ultrasonic-motor","display_name":"Ultrasonic motor","score":0.8239306211471558},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.7854542136192322},{"id":"https://openalex.org/keywords/positioning-system","display_name":"Positioning system","score":0.759650707244873},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.6705429553985596},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6059791445732117},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.5712714791297913},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.47900813817977905},{"id":"https://openalex.org/keywords/ultrasonic-imaging","display_name":"Ultrasonic imaging","score":0.46979984641075134},{"id":"https://openalex.org/keywords/phased-array","display_name":"Phased array","score":0.450831800699234},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.4491925537586212},{"id":"https://openalex.org/keywords/ultrasound","display_name":"Ultrasound","score":0.4464148283004761},{"id":"https://openalex.org/keywords/mechanical-resonance","display_name":"Mechanical resonance","score":0.4274333715438843},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.41662418842315674},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22619768977165222},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12754783034324646},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10478967428207397},{"id":"https://openalex.org/keywords/vibration","display_name":"Vibration","score":0.0968511700630188},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.07434907555580139}],"concepts":[{"id":"https://openalex.org/C138794181","wikidata":"https://www.wikidata.org/wiki/Q10541502","display_name":"Ultrasonic motor","level":3,"score":0.8239306211471558},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.7854542136192322},{"id":"https://openalex.org/C2778603505","wikidata":"https://www.wikidata.org/wiki/Q17141406","display_name":"Positioning system","level":3,"score":0.759650707244873},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.6705429553985596},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6059791445732117},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.5712714791297913},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.47900813817977905},{"id":"https://openalex.org/C2989478337","wikidata":"https://www.wikidata.org/wiki/Q234904","display_name":"Ultrasonic imaging","level":3,"score":0.46979984641075134},{"id":"https://openalex.org/C55494473","wikidata":"https://www.wikidata.org/wiki/Q727898","display_name":"Phased array","level":3,"score":0.450831800699234},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4491925537586212},{"id":"https://openalex.org/C143753070","wikidata":"https://www.wikidata.org/wiki/Q162564","display_name":"Ultrasound","level":2,"score":0.4464148283004761},{"id":"https://openalex.org/C196348190","wikidata":"https://www.wikidata.org/wiki/Q3744733","display_name":"Mechanical resonance","level":3,"score":0.4274333715438843},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.41662418842315674},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22619768977165222},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12754783034324646},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10478967428207397},{"id":"https://openalex.org/C198394728","wikidata":"https://www.wikidata.org/wiki/Q3695508","display_name":"Vibration","level":2,"score":0.0968511700630188},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.07434907555580139},{"id":"https://openalex.org/C21822782","wikidata":"https://www.wikidata.org/wiki/Q131214","display_name":"Antenna (radio)","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cisp-bmei.2018.8633049","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cisp-bmei.2018.8633049","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 11th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5899999737739563,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1982386852","https://openalex.org/W2020026455","https://openalex.org/W2060032703","https://openalex.org/W2488943783","https://openalex.org/W2624212702"],"related_works":["https://openalex.org/W2006140691","https://openalex.org/W4321512240","https://openalex.org/W88316594","https://openalex.org/W4229012123","https://openalex.org/W2367649163","https://openalex.org/W2945394195","https://openalex.org/W2154133417","https://openalex.org/W3180186054","https://openalex.org/W1970081974","https://openalex.org/W4220943096"],"abstract_inverted_index":{"This":[0],"article":[1],"mainly":[2],"introduced":[3],"a":[4,45],"cost":[5],"effective":[6],"mechanical":[7,29,49],"positioning":[8,30,64],"device":[9,50],"in":[10],"MRI-PHIFU(Magnetic":[11],"Resonance":[12],"Imaging-":[13],"Phased":[14],"High-Intensity":[15],"Focused":[16],"Ultrasound)":[17],"system.":[18],"The":[19],"ultimate":[20],"goal":[21],"was":[22,51,75],"to":[23],"implement":[24],"the":[25,28,35,39,43,65,69,72],"control":[26,58],"of":[27,38,47,55,63,71],"accurately,":[31],"which":[32],"based":[33],"on":[34],"ultrasonic":[36,56,66],"transducer":[37],"PHIFU":[40],"system,":[41],"In":[42],"passage,":[44],"design":[46,54],"precision":[48],"proposed,":[52],"including":[53],"motor":[57],"system":[59,74],"and":[60,68],"implementation":[61],"process":[62],"transducer,":[67],"accuracy":[70],"entire":[73],"analyzed.":[76]},"counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
