{"id":"https://openalex.org/W2899479827","doi":"https://doi.org/10.1109/ccta.2018.8511620","title":"Closed Loop Fault Detectability Based on a Gap-Metric","display_name":"Closed Loop Fault Detectability Based on a Gap-Metric","publication_year":2018,"publication_date":"2018-08-01","ids":{"openalex":"https://openalex.org/W2899479827","doi":"https://doi.org/10.1109/ccta.2018.8511620","mag":"2899479827"},"language":"en","primary_location":{"id":"doi:10.1109/ccta.2018.8511620","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccta.2018.8511620","pdf_url":null,"source":{"id":"https://openalex.org/S4306498315","display_name":"2018 IEEE Conference on Control Technology and Applications (CCTA)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Conference on Control Technology and Applications (CCTA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089348283","display_name":"Andr\u00e9 Krabdrup Sekunda","orcid":"https://orcid.org/0000-0002-0094-0743"},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":true,"raw_author_name":"Andre Sekunda","raw_affiliation_strings":["Department of Electrical Engineering, Automation and Control, Tech. University of Denmark, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Automation and Control, Tech. University of Denmark, Denmark","institution_ids":["https://openalex.org/I96673099"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046071840","display_name":"Steven X. Ding","orcid":"https://orcid.org/0000-0002-5149-5918"},"institutions":[{"id":"https://openalex.org/I62318514","display_name":"University of Duisburg-Essen","ror":"https://ror.org/04mz5ra38","country_code":"DE","type":"education","lineage":["https://openalex.org/I62318514"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Steven Ding","raw_affiliation_strings":["Dept. of Automatic Control and Complex Systems, University of Duisburg-Essen, Duisburg, Germany"],"affiliations":[{"raw_affiliation_string":"Dept. of Automatic Control and Complex Systems, University of Duisburg-Essen, Duisburg, Germany","institution_ids":["https://openalex.org/I62318514"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108167187","display_name":"Niels Kj\u00f8lstad Poulsen","orcid":"https://orcid.org/0000-0002-8476-0052"},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Niels Kjolstad Poulsen","raw_affiliation_strings":["Dept. of Applied Mathematics and Computer Science, Tech. University of Denmark, Kgs. Lyngby, Denmark"],"affiliations":[{"raw_affiliation_string":"Dept. of Applied Mathematics and Computer Science, Tech. University of Denmark, Kgs. Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087729927","display_name":"Henrik Niemann","orcid":"https://orcid.org/0000-0002-1518-4979"},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Henrik Niemann","raw_affiliation_strings":["Department of Electrical Engineering, Automation and Control, Tech. University of Denmark, Denmark"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Automation and Control, Tech. University of Denmark, Denmark","institution_ids":["https://openalex.org/I96673099"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5089348283"],"corresponding_institution_ids":["https://openalex.org/I96673099"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.20661157,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"48","issue":null,"first_page":"380","last_page":"385"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9900000095367432,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9889000058174133,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/signature","display_name":"Signature (topology)","score":0.7958582043647766},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.7379209399223328},{"id":"https://openalex.org/keywords/metric","display_name":"Metric (unit)","score":0.722524106502533},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6036818027496338},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5511139631271362},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.532939076423645},{"id":"https://openalex.org/keywords/stuck-at-fault","display_name":"Stuck-at fault","score":0.5176873207092285},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.495328813791275},{"id":"https://openalex.org/keywords/feedback-loop","display_name":"Feedback loop","score":0.41737955808639526},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2801157236099243},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.21273839473724365},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1460912823677063},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.1364978551864624},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.12025436758995056}],"concepts":[{"id":"https://openalex.org/C2779696439","wikidata":"https://www.wikidata.org/wiki/Q7512811","display_name":"Signature (topology)","level":2,"score":0.7958582043647766},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7379209399223328},{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.722524106502533},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6036818027496338},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5511139631271362},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.532939076423645},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.5176873207092285},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.495328813791275},{"id":"https://openalex.org/C186886427","wikidata":"https://www.wikidata.org/wiki/Q5441213","display_name":"Feedback loop","level":2,"score":0.41737955808639526},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2801157236099243},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.21273839473724365},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1460912823677063},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.1364978551864624},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.12025436758995056},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/ccta.2018.8511620","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ccta.2018.8511620","pdf_url":null,"source":{"id":"https://openalex.org/S4306498315","display_name":"2018 IEEE Conference on Control Technology and Applications (CCTA)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Conference on Control Technology and Applications (CCTA)","raw_type":"proceedings-article"},{"id":"pmh:oai:bibliographie.ub.uni-due.de:ubo_mods_00120038","is_oa":false,"landing_page_url":"https://doi.org/10.1109/CCTA.2018.8511620","pdf_url":null,"source":{"id":"https://openalex.org/S7407055102","display_name":"Universit\u00e4tsbibliographie, Universit\u00e4t Duisburg-Essen","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Buchaufsatz/Kapitel"},{"id":"pmh:oai:pure.atira.dk:publications/d6a0c589-8c11-4021-9a0f-0d82366e154a","is_oa":false,"landing_page_url":"https://orbit.dtu.dk/en/publications/d6a0c589-8c11-4021-9a0f-0d82366e154a","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sekunda , A K , Ding , S &amp; Niemann , H H 2018 , Closed Loop Fault Detectability Based on a Gap-metric . in Proceedings of 2018 IEEE Conference on Control Technology and Applications . IEEE , pp. 380-85 , 2018 IEEE Conference on Control Technology and Applications , Copenhagen , Denmark , 21/08/2018 . https://doi.org/10.1109/CCTA.2018.8511620","raw_type":"contributionToPeriodical"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W572601373","https://openalex.org/W607110411","https://openalex.org/W1990067914","https://openalex.org/W2001105875","https://openalex.org/W2005331012","https://openalex.org/W2066418445","https://openalex.org/W2076323680","https://openalex.org/W2119566395","https://openalex.org/W2120804790","https://openalex.org/W2130318261","https://openalex.org/W2179595285","https://openalex.org/W2185148137","https://openalex.org/W2186740391","https://openalex.org/W2554791791","https://openalex.org/W2790323468","https://openalex.org/W2952719362","https://openalex.org/W4231980343","https://openalex.org/W4235457221","https://openalex.org/W4241301900"],"related_works":["https://openalex.org/W1671124163","https://openalex.org/W2168674042","https://openalex.org/W2535275505","https://openalex.org/W3030774134","https://openalex.org/W2104499293","https://openalex.org/W2102771100","https://openalex.org/W2082057679","https://openalex.org/W2169757786","https://openalex.org/W4285494435","https://openalex.org/W855434851"],"abstract_inverted_index":{"Systems":[0],"are":[1,10],"often":[2],"controlled":[3],"using":[4,48,102,118,131],"feedback":[5,18,29],"loops.":[6],"Fault":[7],"diagnosis":[8,22,37],"schemes":[9],"usually":[11],"designed":[12],"assuming":[13],"that":[14],"there":[15],"is":[16,34,46,122],"no":[17],"loop.":[19,30],"Therefore":[20],"fault":[21,36,41,63,78,99],"methods":[23],"need":[24],"to":[25,66,124],"accommodate":[26],"for":[27],"the":[28,49,61,68,74,77,84,89,93,98,108,115,119,126,134],"One":[31],"such":[32],"method":[33,45],"active":[35],"based":[38],"on":[39],"a":[40,103],"signature":[42,64,79,100],"system.":[43,75],"This":[44,86],"derived":[47,62],"YJBK":[50],"parametrisation,":[51],"named":[52],"after":[53],"Youla,":[54],"Jabr,":[55],"Bongiorno":[56],"and":[57],"Kucera.":[58],"It":[59],"uses":[60],"system":[65,80,101],"determine":[67],"detectability":[69,94,127],"of":[70,91,95,110,128],"possible":[71,123],"faults":[72,96,129],"in":[73,97],"Deriving":[76],"requires":[81],"knowledge":[82,113],"about":[83,114,133],"controller.":[85,135],"paper":[87],"demonstrates":[88],"possibility":[90],"estimating":[92],"gap-metric.":[104],"The":[105],"gap-metric":[106,120],"has":[107],"advantage":[109],"only":[111],"requiring":[112],"plant.":[116],"By":[117],"it":[121],"estimate":[125],"without":[130],"information":[132]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
