{"id":"https://openalex.org/W2131280640","doi":"https://doi.org/10.1109/cca.2005.1507346","title":"Robust load frequency controller design for hydro power systems","display_name":"Robust load frequency controller design for hydro power systems","publication_year":2005,"publication_date":"2005-09-12","ids":{"openalex":"https://openalex.org/W2131280640","doi":"https://doi.org/10.1109/cca.2005.1507346","mag":"2131280640"},"language":"en","primary_location":{"id":"doi:10.1109/cca.2005.1507346","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cca.2005.1507346","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of 2005 IEEE Conference on Control Applications, 2005. CCA 2005.","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008943933","display_name":"A. Khodabakhshian","orcid":null},"institutions":[{"id":"https://openalex.org/I170013655","display_name":"Isfahan University of Technology","ror":"https://ror.org/00af3sa43","country_code":"IR","type":"education","lineage":["https://openalex.org/I170013655"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Amin Khodabakhshian","raw_affiliation_strings":["Faculty of Engineering, Isfahan University of Technology, Isfahan, Iran","Fac. of Eng., Isfahan Univ"],"affiliations":[{"raw_affiliation_string":"Faculty of Engineering, Isfahan University of Technology, Isfahan, Iran","institution_ids":["https://openalex.org/I170013655"]},{"raw_affiliation_string":"Fac. of Eng., Isfahan Univ","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5088305855","display_name":"Navid Golbon","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"N. Golbon","raw_affiliation_strings":["NIGC"],"affiliations":[{"raw_affiliation_string":"NIGC","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5008943933"],"corresponding_institution_ids":["https://openalex.org/I170013655"],"apc_list":null,"apc_paid":null,"fwci":1.067,"has_fulltext":false,"cited_by_count":47,"citation_normalized_percentile":{"value":0.79811408,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1510","last_page":"1515"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pid-controller","display_name":"PID controller","score":0.8375173807144165},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.819940447807312},{"id":"https://openalex.org/keywords/open-loop-controller","display_name":"Open-loop controller","score":0.6865992546081543},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.6538248658180237},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.6037627458572388},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5145601630210876},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.508581280708313},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5069385170936584},{"id":"https://openalex.org/keywords/frequency-response","display_name":"Frequency response","score":0.48750731348991394},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.46581247448921204},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.44026902318000793},{"id":"https://openalex.org/keywords/robust-control","display_name":"Robust control","score":0.41103285551071167},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.398353636264801},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27497950196266174},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.24061372876167297},{"id":"https://openalex.org/keywords/closed-loop","display_name":"Closed loop","score":0.22776544094085693},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10751914978027344},{"id":"https://openalex.org/keywords/temperature-control","display_name":"Temperature control","score":0.09690698981285095},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.07042032480239868}],"concepts":[{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.8375173807144165},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.819940447807312},{"id":"https://openalex.org/C161362739","wikidata":"https://www.wikidata.org/wiki/Q2301555","display_name":"Open-loop controller","level":3,"score":0.6865992546081543},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.6538248658180237},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6037627458572388},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5145601630210876},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.508581280708313},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5069385170936584},{"id":"https://openalex.org/C8590192","wikidata":"https://www.wikidata.org/wiki/Q1054694","display_name":"Frequency response","level":2,"score":0.48750731348991394},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46581247448921204},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.44026902318000793},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.41103285551071167},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.398353636264801},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27497950196266174},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.24061372876167297},{"id":"https://openalex.org/C3019251811","wikidata":"https://www.wikidata.org/wiki/Q5135346","display_name":"Closed loop","level":2,"score":0.22776544094085693},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10751914978027344},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.09690698981285095},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.07042032480239868},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cca.2005.1507346","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cca.2005.1507346","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of 2005 IEEE Conference on Control Applications, 2005. CCA 2005.","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1482354191","https://openalex.org/W1538339221","https://openalex.org/W1763243278","https://openalex.org/W2038775651","https://openalex.org/W2050296474","https://openalex.org/W2082687892","https://openalex.org/W2105697135","https://openalex.org/W2152083656","https://openalex.org/W3147402278"],"related_works":["https://openalex.org/W204648549","https://openalex.org/W4244904831","https://openalex.org/W2138996551","https://openalex.org/W1991932840","https://openalex.org/W2515863312","https://openalex.org/W4386075353","https://openalex.org/W1541995305","https://openalex.org/W4391236972","https://openalex.org/W3129383449","https://openalex.org/W3039094874"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,13,21,25,56],"new":[4,51],"approach":[5],"for":[6],"power":[7,16],"system":[8,17,64],"load":[9,52],"frequency":[10,40,53],"control":[11],"of":[12,20,49],"hydro":[14],"turbine":[15],"by":[18],"means":[19],"PID":[22,31],"controller.":[23],"Using":[24],"maximum":[26],"peak":[27],"resonance":[28],"specification,":[29],"the":[30,38,44,61],"controller":[32,54],"parameters":[33],"are":[34],"adjusted":[35],"such":[36],"that":[37],"open-loop":[39],"response":[41],"curve":[42],"follows":[43],"corresponding":[45],"contour.":[46],"Comparative":[47],"results":[48],"this":[50],"and":[55],"conventional":[57],"PI":[58],"one":[59],"show":[60],"improvement":[62],"in":[63],"damping":[65],"considerably":[66]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
