{"id":"https://openalex.org/W4412030705","doi":"https://doi.org/10.1109/cbms65348.2025.00146","title":"Towards Detection of Perfusion Disorders Using Remote Photoplethysmography","display_name":"Towards Detection of Perfusion Disorders Using Remote Photoplethysmography","publication_year":2025,"publication_date":"2025-06-18","ids":{"openalex":"https://openalex.org/W4412030705","doi":"https://doi.org/10.1109/cbms65348.2025.00146"},"language":"en","primary_location":{"id":"doi:10.1109/cbms65348.2025.00146","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cbms65348.2025.00146","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 38th International Symposium on Computer-Based Medical Systems (CBMS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5093998251","display_name":"Samuel Tauber","orcid":null},"institutions":[{"id":"https://openalex.org/I4210100127","display_name":"Fraunhofer Institute for Microelectronic Circuits and Systems","ror":"https://ror.org/01243c877","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210100127","https://openalex.org/I4923324"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Samuel Tauber","raw_affiliation_strings":["Fraunhofer Institute of Microeletronic Circuits and Systems,Duisburg,Germany"],"affiliations":[{"raw_affiliation_string":"Fraunhofer Institute of Microeletronic Circuits and Systems,Duisburg,Germany","institution_ids":["https://openalex.org/I4210100127"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046237871","display_name":"Christian Wiede","orcid":"https://orcid.org/0000-0002-2511-4659"},"institutions":[{"id":"https://openalex.org/I4210100127","display_name":"Fraunhofer Institute for Microelectronic Circuits and Systems","ror":"https://ror.org/01243c877","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210100127","https://openalex.org/I4923324"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Christian Wiede","raw_affiliation_strings":["Fraunhofer Institute of Microeletronic Circuits and Systems,Duisburg,Germany"],"affiliations":[{"raw_affiliation_string":"Fraunhofer Institute of Microeletronic Circuits and Systems,Duisburg,Germany","institution_ids":["https://openalex.org/I4210100127"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5047266984","display_name":"Karsten Seidl","orcid":"https://orcid.org/0000-0001-6197-5037"},"institutions":[{"id":"https://openalex.org/I4210100127","display_name":"Fraunhofer Institute for Microelectronic Circuits and Systems","ror":"https://ror.org/01243c877","country_code":"DE","type":"facility","lineage":["https://openalex.org/I4210100127","https://openalex.org/I4923324"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Karsten Seidl","raw_affiliation_strings":["Fraunhofer Institute of Microeletronic Circuits and Systems,Duisburg,Germany"],"affiliations":[{"raw_affiliation_string":"Fraunhofer Institute of Microeletronic Circuits and Systems,Duisburg,Germany","institution_ids":["https://openalex.org/I4210100127"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5093998251"],"corresponding_institution_ids":["https://openalex.org/I4210100127"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.14996932,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"717","last_page":"718"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9416999816894531,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.929099977016449,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.8816870450973511},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49506106972694397},{"id":"https://openalex.org/keywords/remote-sensing","display_name":"Remote sensing","score":0.40117037296295166},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3454139828681946},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.138026624917984},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.1211615800857544},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.12012243270874023}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.8816870450973511},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49506106972694397},{"id":"https://openalex.org/C62649853","wikidata":"https://www.wikidata.org/wiki/Q199687","display_name":"Remote sensing","level":1,"score":0.40117037296295166},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3454139828681946},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.138026624917984},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.1211615800857544},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.12012243270874023}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/cbms65348.2025.00146","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cbms65348.2025.00146","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 38th International Symposium on Computer-Based Medical Systems (CBMS)","raw_type":"proceedings-article"},{"id":"pmh:oai:publica.fraunhofer.de:publica/512567","is_oa":false,"landing_page_url":"https://publica.fraunhofer.de/handle/publica/512567","pdf_url":null,"source":{"id":"https://openalex.org/S4306400318","display_name":"Fraunhofer-Publica (Fraunhofer-Gesellschaft)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4923324","host_organization_name":"Fraunhofer-Gesellschaft","host_organization_lineage":["https://openalex.org/I4923324"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"conference paper"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W2400255159","https://openalex.org/W3132312126","https://openalex.org/W4283580411","https://openalex.org/W4292794016","https://openalex.org/W4307023714","https://openalex.org/W4390599755","https://openalex.org/W4402191261"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2732360296","https://openalex.org/W1994871954","https://openalex.org/W4297152434","https://openalex.org/W2072858761","https://openalex.org/W1540261775","https://openalex.org/W4239033438","https://openalex.org/W1968279762"],"abstract_inverted_index":{"This":[0,78],"paper":[1],"presents":[2],"a":[3,22,53,85],"novel":[4],"approach":[5],"to":[6],"noninvasively":[7],"assess":[8],"different":[9],"levels":[10],"of":[11,31,67,82],"perfusion":[12,90],"using":[13],"remote":[14],"photoplethysmography":[15],"(rPPG)":[16],"from":[17,46,56],"an":[18],"RGB":[19],"camera.":[20],"In":[21],"proof-of-concept":[23],"study":[24],"involving":[25],"20":[26],"healthy":[27],"participants,":[28],"three":[29],"degrees":[30],"stenosis":[32],"were":[33],"induced":[34],"in":[35],"the":[36,47,57,80],"upper":[37],"extremity":[38],"by":[39],"applying":[40],"external":[41],"pressure.":[42],"The":[43,61],"rPPG":[44,68,83],"signal":[45,55],"affected":[48],"arm":[49],"was":[50],"correlated":[51],"with":[52],"reference":[54],"well-perfused":[58],"control":[59],"arm.":[60],"results":[62],"show":[63],"that":[64],"correlation":[65],"analysis":[66],"signals":[69],"can":[70],"distinguish":[71],"between":[72],"mild,":[73],"moderate,":[74],"and":[75],"full":[76],"stenosis.":[77],"supports":[79],"potential":[81],"as":[84,93],"cost-effective":[86],"tool":[87],"for":[88],"detecting":[89],"disorders":[91],"such":[92],"peripheral":[94],"artery":[95],"disease":[96],"(PAD).":[97]},"counts_by_year":[],"updated_date":"2026-03-28T08:17:26.163206","created_date":"2025-10-10T00:00:00"}
