{"id":"https://openalex.org/W2084285475","doi":"https://doi.org/10.1109/bibe.2013.6701568","title":"Estimation of blood pressure levels from reflective Photoplethysmograph using smart phones","display_name":"Estimation of blood pressure levels from reflective Photoplethysmograph using smart phones","publication_year":2013,"publication_date":"2013-11-01","ids":{"openalex":"https://openalex.org/W2084285475","doi":"https://doi.org/10.1109/bibe.2013.6701568","mag":"2084285475"},"language":"en","primary_location":{"id":"doi:10.1109/bibe.2013.6701568","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bibe.2013.6701568","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"13th IEEE International Conference on BioInformatics and BioEngineering","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015724970","display_name":"Aishwarya Visvanathan","orcid":null},"institutions":[{"id":"https://openalex.org/I55215948","display_name":"Tata Consultancy Services (India)","ror":"https://ror.org/01b9n8m42","country_code":"IN","type":"company","lineage":["https://openalex.org/I4210086519","https://openalex.org/I55215948"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Aishwarya Visvanathan","raw_affiliation_strings":["Innovation Labs, Tata Consultancy Services Ltd, India","Innovation Lab., Tata Consultancy Services Ltd., Bangalore, India"],"affiliations":[{"raw_affiliation_string":"Innovation Labs, Tata Consultancy Services Ltd, India","institution_ids":["https://openalex.org/I55215948"]},{"raw_affiliation_string":"Innovation Lab., Tata Consultancy Services Ltd., Bangalore, India","institution_ids":["https://openalex.org/I55215948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034140949","display_name":"Aniruddha Sinha","orcid":"https://orcid.org/0000-0002-4679-3806"},"institutions":[{"id":"https://openalex.org/I55215948","display_name":"Tata Consultancy Services (India)","ror":"https://ror.org/01b9n8m42","country_code":"IN","type":"company","lineage":["https://openalex.org/I4210086519","https://openalex.org/I55215948"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Aniruddha Sinha","raw_affiliation_strings":["Innovation Labs, Tata Consultancy Services Ltd, India","Innovation Lab., Tata Consultancy Services Ltd., Bangalore, India"],"affiliations":[{"raw_affiliation_string":"Innovation Labs, Tata Consultancy Services Ltd, India","institution_ids":["https://openalex.org/I55215948"]},{"raw_affiliation_string":"Innovation Lab., Tata Consultancy Services Ltd., Bangalore, India","institution_ids":["https://openalex.org/I55215948"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072563444","display_name":"Arpan Pal","orcid":"https://orcid.org/0000-0001-9101-8051"},"institutions":[{"id":"https://openalex.org/I55215948","display_name":"Tata Consultancy Services (India)","ror":"https://ror.org/01b9n8m42","country_code":"IN","type":"company","lineage":["https://openalex.org/I4210086519","https://openalex.org/I55215948"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Arpan Pal","raw_affiliation_strings":["Innovation Labs, Tata Consultancy Services Ltd, India","Innovation Lab., Tata Consultancy Services Ltd., Bangalore, India"],"affiliations":[{"raw_affiliation_string":"Innovation Labs, Tata Consultancy Services Ltd, India","institution_ids":["https://openalex.org/I55215948"]},{"raw_affiliation_string":"Innovation Lab., Tata Consultancy Services Ltd., Bangalore, India","institution_ids":["https://openalex.org/I55215948"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5015724970"],"corresponding_institution_ids":["https://openalex.org/I55215948"],"apc_list":null,"apc_paid":null,"fwci":1.3989,"has_fulltext":false,"cited_by_count":39,"citation_normalized_percentile":{"value":0.81140057,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9948999881744385,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.9616299867630005},{"id":"https://openalex.org/keywords/software-portability","display_name":"Software portability","score":0.7287168502807617},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.6902875900268555},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6304882764816284},{"id":"https://openalex.org/keywords/benchmark","display_name":"Benchmark (surveying)","score":0.5979369282722473},{"id":"https://openalex.org/keywords/smart-phone","display_name":"Smart phone","score":0.5924609899520874},{"id":"https://openalex.org/keywords/usability","display_name":"Usability","score":0.5198960304260254},{"id":"https://openalex.org/keywords/support-vector-machine","display_name":"Support vector machine","score":0.460679829120636},{"id":"https://openalex.org/keywords/estimation","display_name":"Estimation","score":0.4242766499519348},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.40119558572769165},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35541629791259766},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.22759005427360535},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21225622296333313},{"id":"https://openalex.org/keywords/human\u2013computer-interaction","display_name":"Human\u2013computer interaction","score":0.1911894679069519},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.1625554859638214},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.13040819764137268},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.0999327003955841}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.9616299867630005},{"id":"https://openalex.org/C63000827","wikidata":"https://www.wikidata.org/wiki/Q3080428","display_name":"Software portability","level":2,"score":0.7287168502807617},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.6902875900268555},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6304882764816284},{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.5979369282722473},{"id":"https://openalex.org/C2984771860","wikidata":"https://www.wikidata.org/wiki/Q22645","display_name":"Smart phone","level":2,"score":0.5924609899520874},{"id":"https://openalex.org/C170130773","wikidata":"https://www.wikidata.org/wiki/Q216378","display_name":"Usability","level":2,"score":0.5198960304260254},{"id":"https://openalex.org/C12267149","wikidata":"https://www.wikidata.org/wiki/Q282453","display_name":"Support vector machine","level":2,"score":0.460679829120636},{"id":"https://openalex.org/C96250715","wikidata":"https://www.wikidata.org/wiki/Q965330","display_name":"Estimation","level":2,"score":0.4242766499519348},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.40119558572769165},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35541629791259766},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.22759005427360535},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21225622296333313},{"id":"https://openalex.org/C107457646","wikidata":"https://www.wikidata.org/wiki/Q207434","display_name":"Human\u2013computer interaction","level":1,"score":0.1911894679069519},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.1625554859638214},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.13040819764137268},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0999327003955841},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/bibe.2013.6701568","is_oa":false,"landing_page_url":"https://doi.org/10.1109/bibe.2013.6701568","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"13th IEEE International Conference on BioInformatics and BioEngineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1981918735","https://openalex.org/W1987949413","https://openalex.org/W1991170684","https://openalex.org/W1994326378","https://openalex.org/W1995581167","https://openalex.org/W2001140692","https://openalex.org/W2060626619","https://openalex.org/W2072889521","https://openalex.org/W2081390890","https://openalex.org/W2083872334","https://openalex.org/W2102041666","https://openalex.org/W2119821739","https://openalex.org/W2130583484","https://openalex.org/W2135220085","https://openalex.org/W2145992342","https://openalex.org/W2149465371","https://openalex.org/W2308884720","https://openalex.org/W4239510810","https://openalex.org/W6649107907","https://openalex.org/W6668987893"],"related_works":["https://openalex.org/W2732360296","https://openalex.org/W1994871954","https://openalex.org/W4297152434","https://openalex.org/W2072858761","https://openalex.org/W2122132874","https://openalex.org/W4200107443","https://openalex.org/W4239033438","https://openalex.org/W2170552210","https://openalex.org/W4318970012","https://openalex.org/W1968279762"],"abstract_inverted_index":{"As":[0],"part":[1],"of":[2,15,99,116,123,139,168,181,184],"preventive":[3],"healthcare,":[4],"there":[5],"is":[6,40,56,118,128],"a":[7,72,103,121,174],"need":[8],"to":[9,63,74,93,131],"regularly":[10],"monitor":[11],"blood":[12,31],"pressure":[13,32],"(BP)":[14],"cardiac":[16],"patients":[17,62],"and":[18,30,78,97,152,171],"elderly":[19],"people.":[20],"Mobile":[21],"Healthcare,":[22],"measuring":[23],"human":[24],"vitals":[25],"like":[26],"heart":[27],"rate,":[28],"Spo2":[29],"with":[33,88],"smart":[34,50,89,156],"phones":[35,157],"using":[36,84,120],"the":[37,47,76,94,100,133,137,140,179,182],"Photoplethysmography":[38],"technique":[39],"becoming":[41],"widely":[42],"popular.":[43],"But,":[44],"for":[45,61,112],"estimating":[46],"BP,":[48],"multiple":[49],"phone":[51],"sensors":[52],"or":[53,109],"additional":[54],"hardware":[55],"required,":[57],"which":[58,91],"causes":[59],"uneasiness":[60],"use":[64],"it,":[65],"individually.":[66],"In":[67],"this":[68],"paper,":[69],"we":[70],"present":[71],"methodology":[73],"estimate":[75,132],"systolic":[77],"diastolic":[79],"BP":[80,117,134,185],"levels":[81,115,135],"by":[82,164],"only":[83],"PPG":[85,124,143],"signals":[86],"captured":[87,142,154],"phones,":[90],"adds":[92],"affordability,":[95],"usability":[96],"portability":[98],"system.":[101],"Initially,":[102],"training":[104],"model":[105,127],"(Linear":[106],"Regression":[107],"Model":[108],"SVM":[110],"Model)":[111],"various":[113],"known":[114],"created":[119],"set":[122],"features.":[125],"This":[126],"later":[129],"used":[130],"from":[136,155],"features":[138],"newly":[141],"signals.":[144],"Experiments":[145],"are":[146],"performed":[147],"on":[148],"benchmark":[149],"hospital":[150],"dataset":[151],"data":[153],"in":[158,177],"our":[159],"lab.":[160],"Results":[161],"indicate":[162],"that":[163],"additionally":[165],"adding":[166],"information":[167],"height,":[169],"weight":[170],"age":[172],"play":[173],"vital":[175],"role":[176],"increasing":[178],"accuracy":[180],"estimation":[183],"levels.":[186]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":6},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
