{"id":"https://openalex.org/W2769333345","doi":"https://doi.org/10.1109/afrcon.2017.8095654","title":"Off-load tap-change transformer impact under high distributed PV generation","display_name":"Off-load tap-change transformer impact under high distributed PV generation","publication_year":2017,"publication_date":"2017-09-01","ids":{"openalex":"https://openalex.org/W2769333345","doi":"https://doi.org/10.1109/afrcon.2017.8095654","mag":"2769333345"},"language":"en","primary_location":{"id":"doi:10.1109/afrcon.2017.8095654","is_oa":false,"landing_page_url":"https://doi.org/10.1109/afrcon.2017.8095654","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE AFRICON","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5069724363","display_name":"Zama Goqo","orcid":null},"institutions":[{"id":"https://openalex.org/I95023434","display_name":"University of KwaZulu-Natal","ror":"https://ror.org/04qzfn040","country_code":"ZA","type":"education","lineage":["https://openalex.org/I95023434"]}],"countries":["ZA"],"is_corresponding":true,"raw_author_name":"Zama Goqo","raw_affiliation_strings":["School of Engineering, University of KwaZulu-Natal, Durban, South Africa"],"affiliations":[{"raw_affiliation_string":"School of Engineering, University of KwaZulu-Natal, Durban, South Africa","institution_ids":["https://openalex.org/I95023434"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017517034","display_name":"Sanjeeth Sewchurran","orcid":null},"institutions":[{"id":"https://openalex.org/I2803062987","display_name":"eThekwini Municipality","ror":"https://ror.org/01g1ykj19","country_code":"ZA","type":"government","lineage":["https://openalex.org/I2803062987"]}],"countries":["ZA"],"is_corresponding":false,"raw_author_name":"Sanjeeth Sewchurran","raw_affiliation_strings":["Ethekwini Electricity, Ethekwini Municipality, Durban, South Africa"],"affiliations":[{"raw_affiliation_string":"Ethekwini Electricity, Ethekwini Municipality, Durban, South Africa","institution_ids":["https://openalex.org/I2803062987"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040134899","display_name":"David G. Dorrell","orcid":"https://orcid.org/0000-0001-8060-3386"},"institutions":[{"id":"https://openalex.org/I95023434","display_name":"University of KwaZulu-Natal","ror":"https://ror.org/04qzfn040","country_code":"ZA","type":"education","lineage":["https://openalex.org/I95023434"]}],"countries":["ZA"],"is_corresponding":false,"raw_author_name":"David Dorrell","raw_affiliation_strings":["School of Engineering, University of KwaZulu-Natal, Durban, South Africa"],"affiliations":[{"raw_affiliation_string":"School of Engineering, University of KwaZulu-Natal, Durban, South Africa","institution_ids":["https://openalex.org/I95023434"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5069724363"],"corresponding_institution_ids":["https://openalex.org/I95023434"],"apc_list":null,"apc_paid":null,"fwci":0.2921,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.61506348,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1208","last_page":"1213"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.992900013923645,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.7555602192878723},{"id":"https://openalex.org/keywords/tap-changer","display_name":"Tap changer","score":0.6651907563209534},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5858803987503052},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5680823922157288},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.48960214853286743},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.4703381657600403},{"id":"https://openalex.org/keywords/stand-alone-power-system","display_name":"Stand-alone power system","score":0.4519098997116089},{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.43318304419517517},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3915215730667114},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3827991783618927},{"id":"https://openalex.org/keywords/environmental-economics","display_name":"Environmental economics","score":0.37041646242141724},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3659168481826782},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3568425178527832},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3435632586479187},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.34068864583969116},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.22790130972862244},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.1504913866519928}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7555602192878723},{"id":"https://openalex.org/C122940293","wikidata":"https://www.wikidata.org/wiki/Q1755966","display_name":"Tap changer","level":4,"score":0.6651907563209534},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5858803987503052},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5680823922157288},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.48960214853286743},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.4703381657600403},{"id":"https://openalex.org/C104708988","wikidata":"https://www.wikidata.org/wiki/Q1664450","display_name":"Stand-alone power system","level":4,"score":0.4519098997116089},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.43318304419517517},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3915215730667114},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3827991783618927},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.37041646242141724},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3659168481826782},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3568425178527832},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3435632586479187},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34068864583969116},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.22790130972862244},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.1504913866519928}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/afrcon.2017.8095654","is_oa":false,"landing_page_url":"https://doi.org/10.1109/afrcon.2017.8095654","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE AFRICON","raw_type":"proceedings-article"},{"id":"pmh:oai:opus.lib.uts.edu.au:10453/127469","is_oa":false,"landing_page_url":"http://hdl.handle.net/10453/127469","pdf_url":null,"source":{"id":"https://openalex.org/S4306401357","display_name":"UTS ePRESS (University of Technology Sydney)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I114017466","host_organization_name":"University of Technology Sydney","host_organization_lineage":["https://openalex.org/I114017466"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Conference Proceeding"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1914845925","https://openalex.org/W2101067456","https://openalex.org/W2142311871","https://openalex.org/W2329751680","https://openalex.org/W2490609050","https://openalex.org/W2514119088","https://openalex.org/W2554790990","https://openalex.org/W2564515602","https://openalex.org/W2564698800","https://openalex.org/W2566769150","https://openalex.org/W2740625440","https://openalex.org/W6731093580"],"related_works":["https://openalex.org/W4396855483","https://openalex.org/W4367308590","https://openalex.org/W1982630147","https://openalex.org/W4293195515","https://openalex.org/W2904682530","https://openalex.org/W4296443375","https://openalex.org/W4220659476","https://openalex.org/W2325807929","https://openalex.org/W2501673021","https://openalex.org/W3041478332"],"abstract_inverted_index":{"Distributed":[0],"solar":[1,21,45,81,136],"photovoltaic":[2],"(PV)":[3],"generation":[4],"market":[5],"continues":[6],"to":[7,155],"grow":[8],"with":[9,129],"increasing":[10],"operational":[11],"challenges":[12],"for":[13,38],"distribution":[14,32,75,87,108,145],"network":[15,59,91,101,121,146],"operators.":[16,60],"In":[17],"South":[18],"Africa,":[19],"residential":[20,143],"PV":[22,46,82,137],"system":[23],"projects":[24,40],"have":[25],"also":[26,124],"been":[27],"implemented":[28],"in":[29,54,96,112,152],"low":[30,72],"voltage":[31,73,105],"networks,":[33],"and":[34,51,56,107,134],"there":[35],"are":[36,123],"plans":[37],"future":[39],"at":[41,126],"municipal":[42],"level.":[43],"Residential":[44],"growth":[47],"introduces":[48],"more":[49,70],"technical":[50,66],"economic":[52],"concerns":[53],"municipalities":[55],"electricity":[57],"utility":[58],"This":[61],"paper":[62,98,154],"focusses":[63],"on":[64,84,120],"a":[65,69],"investigation":[67],"of":[68,93,147],"practical":[71],"(LV)":[74],"transformer":[76,158],"performance":[77],"under":[78],"high":[79],"distributed":[80],"connections":[83],"eThekwini":[85,148],"Electricity":[86,149],"network.":[88],"The":[89],"main":[90],"parameters":[92,122],"interest":[94],"investigated":[95],"this":[97,153],"include":[99],"LV":[100,144],"power":[102,110],"flow,":[103],"line":[104],"dynamics":[106],"feeder":[109],"losses":[111],"steady":[113],"state.":[114],"Customer":[115],"day":[116],"load":[117],"demand":[118],"effects":[119],"analyzed,":[125],"discrete":[127,130],"levels,":[128],"off-load":[131],"tap-changer":[132],"positions":[133],"different":[135],"penetration":[138],"levels.":[139],"A":[140],"case":[141],"study":[142],"is":[150],"used":[151],"assess":[156],"central":[157],"performance.":[159]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2018,"cited_by_count":2}],"updated_date":"2026-04-05T17:49:38.594831","created_date":"2025-10-10T00:00:00"}
