{"id":"https://openalex.org/W1984553265","doi":"https://doi.org/10.1109/afrcon.2011.6072137","title":"Dual Active Bridge for Energy Storage System in Small Wind Turbine","display_name":"Dual Active Bridge for Energy Storage System in Small Wind Turbine","publication_year":2011,"publication_date":"2011-09-01","ids":{"openalex":"https://openalex.org/W1984553265","doi":"https://doi.org/10.1109/afrcon.2011.6072137","mag":"1984553265"},"language":"en","primary_location":{"id":"doi:10.1109/afrcon.2011.6072137","is_oa":false,"landing_page_url":"https://doi.org/10.1109/afrcon.2011.6072137","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Africon '11","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5086994169","display_name":"Micha\u0142 Rolak","orcid":"https://orcid.org/0000-0003-3579-3883"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"Michal Rolak","raw_affiliation_strings":["Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland","Institute of Control and Industrial Electronics / Warsaw University of Technology, Poland"],"affiliations":[{"raw_affiliation_string":"Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]},{"raw_affiliation_string":"Institute of Control and Industrial Electronics / Warsaw University of Technology, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5009004635","display_name":"Mariusz Malinowski","orcid":"https://orcid.org/0000-0002-4697-8261"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mariusz Malinowski","raw_affiliation_strings":["Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland","Institute of Control and Industrial Electronics / Warsaw University of Technology, Poland"],"affiliations":[{"raw_affiliation_string":"Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]},{"raw_affiliation_string":"Institute of Control and Industrial Electronics / Warsaw University of Technology, Poland","institution_ids":["https://openalex.org/I108403487"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5086994169"],"corresponding_institution_ids":["https://openalex.org/I108403487"],"apc_list":null,"apc_paid":null,"fwci":1.9575,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.87641812,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.7174725532531738},{"id":"https://openalex.org/keywords/galvanic-isolation","display_name":"Galvanic isolation","score":0.6624022722244263},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.6587370038032532},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.6080180406570435},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.5959985256195068},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.554195761680603},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.5393936038017273},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48164668679237366},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.4769253134727478},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.45180901885032654},{"id":"https://openalex.org/keywords/maximum-power-transfer-theorem","display_name":"Maximum power transfer theorem","score":0.43921148777008057},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.39582639932632446},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3894263505935669},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.11618328094482422},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10676273703575134}],"concepts":[{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.7174725532531738},{"id":"https://openalex.org/C70234604","wikidata":"https://www.wikidata.org/wiki/Q780813","display_name":"Galvanic isolation","level":4,"score":0.6624022722244263},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6587370038032532},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.6080180406570435},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.5959985256195068},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.554195761680603},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.5393936038017273},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48164668679237366},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.4769253134727478},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.45180901885032654},{"id":"https://openalex.org/C67186554","wikidata":"https://www.wikidata.org/wiki/Q17103352","display_name":"Maximum power transfer theorem","level":3,"score":0.43921148777008057},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39582639932632446},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3894263505935669},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.11618328094482422},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10676273703575134},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/afrcon.2011.6072137","is_oa":false,"landing_page_url":"https://doi.org/10.1109/afrcon.2011.6072137","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Africon '11","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9100000262260437}],"awards":[],"funders":[{"id":"https://openalex.org/F4320310077","display_name":"National Research Centre","ror":"https://ror.org/02n85j827"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1953915320","https://openalex.org/W2092415532","https://openalex.org/W2098984052","https://openalex.org/W2103897365","https://openalex.org/W2133463397","https://openalex.org/W2154309819","https://openalex.org/W6640787341","https://openalex.org/W6675731687"],"related_works":["https://openalex.org/W631083485","https://openalex.org/W4313452936","https://openalex.org/W2097026685","https://openalex.org/W2480068220","https://openalex.org/W2102542442","https://openalex.org/W1986220761","https://openalex.org/W2070883797","https://openalex.org/W2049526694","https://openalex.org/W4285031945","https://openalex.org/W4387546336"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3],"solution":[4],"of":[5,18,44,59,73,79],"Energy":[6],"Storage":[7],"System":[8],"(ESS)":[9],"for":[10,21,86],"Small":[11],"Wind":[12],"Turbine":[13],"(SWT).":[14],"Two":[15],"different":[16],"topologies":[17],"DC/DC":[19],"converters":[20],"ESS":[22],"are":[23,62],"described.":[24],"Chosen":[25],"Dual":[26],"Active":[27],"Bridge":[28],"(DAB)":[29],"topology":[30],"is":[31,84],"verified":[32],"by":[33],"simulations.":[34],"It":[35],"allows":[36],"to":[37],"deal":[38],"with":[39,70],"difference":[40],"between":[41],"voltage":[42],"levels":[43],"dc-link":[45],"and":[46,50,56,64],"energy":[47,60,74],"storage":[48,61,75],"(ES)":[49],"additionally":[51],"ensures":[52],"galvanic":[53],"isolation.":[54],"Charging":[55],"discharging":[57],"strategies":[58],"described":[63],"simulated.":[65],"A":[66],"superior":[67],"control":[68],"circuit":[69],"assured":[71],"protection":[72],"system,":[76],"which":[77],"consist":[78],"four":[80],"parallel":[81],"PI":[82],"controllers":[83],"presented":[85],"bidirectional":[87],"power":[88],"transfer.":[89]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-01-10T23:39:48.068659","created_date":"2025-10-10T00:00:00"}
