{"id":"https://openalex.org/W3094180995","doi":"https://doi.org/10.1109/wf-iot48130.2020.9221386","title":"PPG Based Continuous Blood Pressure Monitoring Framework for Smart Home Environment","display_name":"PPG Based Continuous Blood Pressure Monitoring Framework for Smart Home Environment","publication_year":2020,"publication_date":"2020-06-01","ids":{"openalex":"https://openalex.org/W3094180995","doi":"https://doi.org/10.1109/wf-iot48130.2020.9221386","mag":"3094180995"},"language":"en","primary_location":{"id":"doi:10.1109/wf-iot48130.2020.9221386","is_oa":false,"landing_page_url":"https://doi.org/10.1109/wf-iot48130.2020.9221386","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 6th World Forum on Internet of Things (WF-IoT)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006113072","display_name":"Rajdeep Kumar Nath","orcid":"https://orcid.org/0009-0004-7032-8623"},"institutions":[{"id":"https://openalex.org/I143302722","display_name":"University of Kentucky","ror":"https://ror.org/02k3smh20","country_code":"US","type":"education","lineage":["https://openalex.org/I143302722"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Rajdeep Kumar Nath","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Kentucky, Lexington, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Kentucky, Lexington, USA","institution_ids":["https://openalex.org/I143302722"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091267392","display_name":"Himanshu Thapliyal","orcid":"https://orcid.org/0000-0001-9157-4517"},"institutions":[{"id":"https://openalex.org/I143302722","display_name":"University of Kentucky","ror":"https://ror.org/02k3smh20","country_code":"US","type":"education","lineage":["https://openalex.org/I143302722"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Himanshu Thapliyal","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Kentucky, Lexington, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Kentucky, Lexington, USA","institution_ids":["https://openalex.org/I143302722"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I143302722"],"apc_list":null,"apc_paid":null,"fwci":1.8129,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.84781652,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.8510040044784546},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.7991275787353516},{"id":"https://openalex.org/keywords/standard-deviation","display_name":"Standard deviation","score":0.6135895848274231},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5552446842193604},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.5149465203285217},{"id":"https://openalex.org/keywords/cuff","display_name":"Cuff","score":0.5100625157356262},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.3696654438972473},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.3353227972984314},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.2524036765098572},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.23268401622772217},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.22170725464820862},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.14552521705627441},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.10951295495033264},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.07528677582740784},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.07141473889350891}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.8510040044784546},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.7991275787353516},{"id":"https://openalex.org/C22679943","wikidata":"https://www.wikidata.org/wiki/Q159375","display_name":"Standard deviation","level":2,"score":0.6135895848274231},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5552446842193604},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.5149465203285217},{"id":"https://openalex.org/C2780017030","wikidata":"https://www.wikidata.org/wiki/Q368366","display_name":"Cuff","level":2,"score":0.5100625157356262},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.3696654438972473},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.3353227972984314},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.2524036765098572},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.23268401622772217},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.22170725464820862},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.14552521705627441},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.10951295495033264},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.07528677582740784},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.07141473889350891}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/wf-iot48130.2020.9221386","is_oa":false,"landing_page_url":"https://doi.org/10.1109/wf-iot48130.2020.9221386","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 6th World Forum on Internet of Things (WF-IoT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1933258993","https://openalex.org/W2086034829","https://openalex.org/W2101234009","https://openalex.org/W2110576716","https://openalex.org/W2162800060","https://openalex.org/W2431637923","https://openalex.org/W2755048715","https://openalex.org/W2790723868","https://openalex.org/W3099743694","https://openalex.org/W6675354045"],"related_works":["https://openalex.org/W2156628018","https://openalex.org/W1987077480","https://openalex.org/W4320519676","https://openalex.org/W2794656031","https://openalex.org/W110588529","https://openalex.org/W2999661930","https://openalex.org/W2915051771","https://openalex.org/W4366773847","https://openalex.org/W2519342842","https://openalex.org/W2499100327"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3],"have":[4],"proposed":[5,19,105],"a":[6,70,77,88,95],"computational":[7],"framework":[8,20,106],"for":[9,35,45,111,117],"continuous":[10,121],"blood":[11,51,67,85,122,132],"pressure":[12,68,86,123,133],"estimation":[13],"using":[14],"Photoplethysmogram":[15],"(PPG)":[16],"signal.":[17],"The":[18,29,100],"is":[21,107],"evaluated":[22],"on":[23,130],"the":[24,40,47,56,83,104,114,131],"publicly":[25],"available":[26],"MIMIC":[27],"Database.":[28],"database":[30],"contains":[31],"raw":[32],"PPG":[33],"data":[34],"different":[36],"users":[37],"and":[38,49,76,82,94],"also":[39],"Arterial":[41],"Blood":[42],"Pressure":[43],"(ABP)":[44],"calculating":[46],"systolic":[48,66],"diastolic":[50,84],"pressure.":[52],"Results":[53],"showed":[54],"that":[55,103],"Decision":[57],"Tree":[58],"Regressor":[59],"boosted":[60],"by":[61],"Adaboost":[62],"regressor":[63],"could":[64],"estimate":[65],"with":[69,87,113,137],"mean":[71,89],"average":[72,90],"error":[73,91],"of":[74,80,92,98,134,140],"2.07":[75],"standard":[78,96],"deviation":[79,97],"5.97":[81],"1.15":[93],"4.05.":[99],"results":[101],"indicate":[102],"an":[108,135],"ideal":[109],"candidate":[110],"integrating":[112],"wearable":[115],"devices":[116],"unobtrusive":[118],"cuff":[119],"less":[120],"monitoring":[124],"to":[125],"provide":[126],"real":[127],"time":[128],"update":[129],"individual":[136],"high":[138],"degree":[139],"accuracy.":[141]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":2}],"updated_date":"2026-08-27T14:10:00.468798","created_date":"2025-10-10T00:00:00"}
