{"id":"https://openalex.org/W3094629313","doi":"https://doi.org/10.1109/wf-iot48130.2020.9221310","title":"Real-Time Implementation of Secure Distributed State Estimation for Networked Microgrids","display_name":"Real-Time Implementation of Secure Distributed State Estimation for Networked Microgrids","publication_year":2020,"publication_date":"2020-06-01","ids":{"openalex":"https://openalex.org/W3094629313","doi":"https://doi.org/10.1109/wf-iot48130.2020.9221310","mag":"3094629313"},"language":"en","primary_location":{"id":"doi:10.1109/wf-iot48130.2020.9221310","is_oa":false,"landing_page_url":"https://doi.org/10.1109/wf-iot48130.2020.9221310","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 6th World Forum on Internet of Things (WF-IoT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078453223","display_name":"Mehmet H. Cintuglu","orcid":"https://orcid.org/0000-0002-0675-4589"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Mehmet Cintuglu","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012066427","display_name":"Anil Kondabathini","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Anil Kondabathini","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5103105665","display_name":"Dmitry Ishchenko","orcid":"https://orcid.org/0000-0002-4693-9713"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dmitry Ishchenko","raw_affiliation_strings":[],"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5078453223"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4413,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.62934395,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8811674118041992},{"id":"https://openalex.org/keywords/iec-61850","display_name":"IEC 61850","score":0.8803952932357788},{"id":"https://openalex.org/keywords/scada","display_name":"SCADA","score":0.6553855538368225},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6203399896621704},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.6153768301010132},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5503442287445068},{"id":"https://openalex.org/keywords/interoperability","display_name":"Interoperability","score":0.4820576608181},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.45644667744636536},{"id":"https://openalex.org/keywords/communications-protocol","display_name":"Communications protocol","score":0.4530080556869507},{"id":"https://openalex.org/keywords/cyber-physical-system","display_name":"Cyber-physical system","score":0.437425434589386},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.36586856842041016},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2856748700141907},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.12849438190460205},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.11565661430358887}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8811674118041992},{"id":"https://openalex.org/C2778907243","wikidata":"https://www.wikidata.org/wiki/Q168160","display_name":"IEC 61850","level":3,"score":0.8803952932357788},{"id":"https://openalex.org/C113863187","wikidata":"https://www.wikidata.org/wiki/Q17498","display_name":"SCADA","level":2,"score":0.6553855538368225},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6203399896621704},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.6153768301010132},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5503442287445068},{"id":"https://openalex.org/C20136886","wikidata":"https://www.wikidata.org/wiki/Q749647","display_name":"Interoperability","level":2,"score":0.4820576608181},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.45644667744636536},{"id":"https://openalex.org/C12269588","wikidata":"https://www.wikidata.org/wiki/Q132364","display_name":"Communications protocol","level":2,"score":0.4530080556869507},{"id":"https://openalex.org/C179768478","wikidata":"https://www.wikidata.org/wiki/Q1120057","display_name":"Cyber-physical system","level":2,"score":0.437425434589386},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.36586856842041016},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2856748700141907},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.12849438190460205},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.11565661430358887},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/wf-iot48130.2020.9221310","is_oa":false,"landing_page_url":"https://doi.org/10.1109/wf-iot48130.2020.9221310","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE 6th World Forum on Internet of Things (WF-IoT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.41999998688697815}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1598852905","https://openalex.org/W1983933235","https://openalex.org/W1984563492","https://openalex.org/W2032987408","https://openalex.org/W2038651258","https://openalex.org/W2159585070","https://openalex.org/W2319020291","https://openalex.org/W2319367234","https://openalex.org/W2514321391","https://openalex.org/W2525022545","https://openalex.org/W2545849206","https://openalex.org/W2594271067","https://openalex.org/W2625585483","https://openalex.org/W2780801472","https://openalex.org/W2918996965","https://openalex.org/W2963157432","https://openalex.org/W4256571797"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2367739416","https://openalex.org/W2057975886","https://openalex.org/W4308700935","https://openalex.org/W2377759402","https://openalex.org/W3173705016","https://openalex.org/W2367606288","https://openalex.org/W2133046344","https://openalex.org/W2141340249","https://openalex.org/W1605582558"],"abstract_inverted_index":{"State":[0],"estimation":[1,55,82,89],"functionality":[2],"is":[3,118,162],"essential":[4],"for":[5,52,107,164,184],"future":[6],"power":[7,43],"grids":[8,44],"operations":[9],"especially":[10],"with":[11,45,136,178],"the":[12,42,86,124,131,140,194,201],"increased":[13],"Distributed":[14],"Energy":[15],"Resources":[16],"(DER)":[17],"and":[18,27,32,56,73,96,110,130,143,205],"microgrids":[19,129],"penetration,":[20],"as":[21,59,139],"it":[22],"can":[23],"enhance":[24],"system":[25],"observability":[26],"help":[28],"improving":[29],"DER":[30,47,72,155],"management":[31],"control":[33,57,134],"in":[34,99,211],"DER-rich":[35],"energy":[36],"delivery":[37],"systems.":[38],"Decentralized":[39],"nature":[40,70],"of":[41,71,76,112,120,127],"high":[46],"penetration":[48],"necessitates":[49],"distributed":[50,80,87,101,132,185],"implementation":[51,109],"both":[53],"state":[54,81,88],"applications,":[58],"centralized":[60],"approaches":[61],"may":[62],"no":[63],"longer":[64],"be":[65],"feasible":[66],"due":[67],"to":[68],"intermittent":[69],"communication":[74,169],"latencies":[75],"traditional":[77],"SCADA.":[78],"Secure":[79],"(SDSE)":[83],"further":[84],"enhances":[85],"algorithm":[90],"by":[91,151],"addressing":[92],"misbehaving":[93],"node":[94],"detection":[95],"isolation":[97],"issues":[98],"a":[100,105,147,212],"environment.This":[102],"paper":[103],"presents":[104],"framework":[106,117,199],"real-time":[108,196],"verification":[111],"cyber-physical":[113,197],"SDSE.":[114],"The":[115,188],"developed":[116,195],"comprised":[119],"power-hardware-in-the-loop":[121],"setup":[122],"representing":[123],"electrical":[125],"model":[126,157,177],"networked":[128],"microgrid":[133,148],"platform":[135],"peer-to-peer":[137],"communications":[138],"cyber":[141],"infrastructure.Communication":[142],"interoperability":[144],"architectures":[145],"within":[146],"are":[149],"established":[150],"leveraging":[152],"IEC":[153,159],"61850":[154,160],"data":[156,176,203,207],"extensions.":[158],"GOOSE":[161],"applied":[163],"inter-microgrid":[165],"communication,":[166],"while":[167],"intra-microgrid":[168],"uses":[170],"Open":[171],"Field":[172],"Message":[173],"Bus":[174],"(OpenFMB)":[175],"Data":[179],"Distribution":[180],"Service":[181],"(DDS)":[182],"protocol":[183],"publish/subscribe":[186],"messaging.":[187],"case":[189],"study":[190],"investigation":[191],"illustrates":[192],"how":[193],"security":[198,209],"addresses":[200],"emerging":[202],"integrity":[204],"false":[206],"injection":[208],"problems":[210],"multi-microgrid":[213],"environment.":[214]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
