{"id":"https://openalex.org/W2898633255","doi":"https://doi.org/10.1109/vlsic.2018.8502407","title":"A 95.3% Peak Efficiency, 135NA Quiescent Current Buck-Boost DC-DC Converter with Current-Slope-Based Mode Control","display_name":"A 95.3% Peak Efficiency, 135NA Quiescent Current Buck-Boost DC-DC Converter with Current-Slope-Based Mode Control","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2898633255","doi":"https://doi.org/10.1109/vlsic.2018.8502407","mag":"2898633255"},"language":"en","primary_location":{"id":"doi:10.1109/vlsic.2018.8502407","is_oa":false,"landing_page_url":"https://doi.org/10.1109/vlsic.2018.8502407","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Symposium on VLSI Circuits","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006013818","display_name":"Danzhu Lu","orcid":"https://orcid.org/0000-0001-6490-5237"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Danzhu Lu","raw_affiliation_strings":["Analog Devices, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analog Devices, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101598505","display_name":"Peng Liu","orcid":"https://orcid.org/0000-0003-3511-6161"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Peng Liu","raw_affiliation_strings":["Analog Devices, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analog Devices, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049856664","display_name":"Suyi Yao","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Suyi Yao","raw_affiliation_strings":["Analog Devices, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analog Devices, Shanghai, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066323377","display_name":"Langyuan Wang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Langyuan Wang","raw_affiliation_strings":["Analog Devices, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analog Devices, Shanghai, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101518513","display_name":"Jie He","orcid":"https://orcid.org/0000-0003-2756-1628"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jie He","raw_affiliation_strings":["Analog Devices, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Analog Devices, Shanghai, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"223","last_page":"224"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":0.9919000267982483,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.7164418697357178},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.6555942296981812},{"id":"https://openalex.org/keywords/\u0107uk-converter","display_name":"\u0106uk converter","score":0.4965885281562805},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.4784108102321625},{"id":"https://openalex.org/keywords/buck\u2013boost-converter","display_name":"Buck\u2013boost converter","score":0.4711253345012665},{"id":"https://openalex.org/keywords/mode","display_name":"Mode (computer interface)","score":0.4634864628314972},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.44075438380241394},{"id":"https://openalex.org/keywords/peak-current","display_name":"Peak current","score":0.4255380928516388},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4116447865962982},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.35457709431648254},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3398963212966919},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.31209373474121094},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2922194004058838},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.27563726902008057},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2668495774269104},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.26545199751853943},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.13839218020439148}],"concepts":[{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.7164418697357178},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.6555942296981812},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.4965885281562805},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.4784108102321625},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.4711253345012665},{"id":"https://openalex.org/C48677424","wikidata":"https://www.wikidata.org/wiki/Q6888088","display_name":"Mode (computer interface)","level":2,"score":0.4634864628314972},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.44075438380241394},{"id":"https://openalex.org/C2982819079","wikidata":"https://www.wikidata.org/wiki/Q1185136","display_name":"Peak current","level":4,"score":0.4255380928516388},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4116447865962982},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35457709431648254},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3398963212966919},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.31209373474121094},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2922194004058838},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.27563726902008057},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2668495774269104},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.26545199751853943},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.13839218020439148},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C52859227","wikidata":"https://www.wikidata.org/wiki/Q7877","display_name":"Electrochemistry","level":3,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/vlsic.2018.8502407","is_oa":false,"landing_page_url":"https://doi.org/10.1109/vlsic.2018.8502407","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE Symposium on VLSI Circuits","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8700000047683716,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2169705106","https://openalex.org/W2249417072","https://openalex.org/W2134431346","https://openalex.org/W2945746437","https://openalex.org/W2922286721","https://openalex.org/W3023706037","https://openalex.org/W2798590431","https://openalex.org/W2168219526","https://openalex.org/W2104535426","https://openalex.org/W2789103314"],"abstract_inverted_index":{"A":[0],"current-slope-based":[1],"mode":[2,15],"control":[3],"method":[4],"is":[5,55,64],"proposed":[6],"for":[7],"a":[8,44,67],"buck-boost":[9],"DC-DC":[10],"converter":[11,35],"to":[12,49],"realize":[13],"automatic":[14],"switching":[16,23],"between":[17],"buck":[18],"and":[19,40,60],"boost":[20],"in":[21,31,71],"one":[22],"period":[24],"without":[25],"additional":[26],"quiescent":[27],"current":[28,52],"(IQ).":[29],"Implemented":[30],"0.18\u03bcm":[32],"CMOS,":[33],"the":[34,72],"realizes":[36],"95.3%":[37],"peak":[38],"efficiency":[39],"above":[41],"90%":[42],"over":[43],"load":[45],"range":[46],"from":[47],"15\u03bcA":[48],"200mA.":[50],"Accurate":[51],"slope":[53],"measurement":[54],"achieved":[56,65],"with":[57,66],"initial":[58],"sampling":[59],"135nA":[61],"total":[62],"IQ":[63],"zero-IQ":[68],"pull-up":[69],"structure":[70],"input":[73],"monitor.":[74]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
