{"id":"https://openalex.org/W2810146224","doi":"https://doi.org/10.1109/uic-atc.2017.8397436","title":"Temperature management system to prevent heat shock in households for elderly people","display_name":"Temperature management system to prevent heat shock in households for elderly people","publication_year":2017,"publication_date":"2017-08-01","ids":{"openalex":"https://openalex.org/W2810146224","doi":"https://doi.org/10.1109/uic-atc.2017.8397436","mag":"2810146224"},"language":"en","primary_location":{"id":"doi:10.1109/uic-atc.2017.8397436","is_oa":false,"landing_page_url":"https://doi.org/10.1109/uic-atc.2017.8397436","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE SmartWorld, Ubiquitous Intelligence &amp; Computing, Advanced &amp; Trusted Computed, Scalable Computing &amp; Communications, Cloud &amp; Big Data Computing, Internet of People and Smart City Innovation (SmartWorld/SCALCOM/UIC/ATC/CBDCom/IOP/SCI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101560257","display_name":"Kanae Matsui","orcid":"https://orcid.org/0000-0002-4289-5848"},"institutions":[{"id":"https://openalex.org/I203951103","display_name":"Keio University","ror":"https://ror.org/02kn6nx58","country_code":"JP","type":"education","lineage":["https://openalex.org/I203951103"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kanae Matsui","raw_affiliation_strings":["Science and Engineering, Keio University, Saitama-City, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Science and Engineering, Keio University, Saitama-City, Japan","institution_ids":["https://openalex.org/I203951103"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060659624","display_name":"Hanjong Choi","orcid":null},"institutions":[{"id":"https://openalex.org/I165522056","display_name":"Tokyo Denki University","ror":"https://ror.org/01pa62v70","country_code":"JP","type":"education","lineage":["https://openalex.org/I165522056"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Hanjong Choi","raw_affiliation_strings":["Science and Engineering, Tokyo Denki University, Saitama-City, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Science and Engineering, Tokyo Denki University, Saitama-City, Japan","institution_ids":["https://openalex.org/I165522056"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.22683569,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":"82","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11244","display_name":"Climate Change and Health Impacts","score":0.991100013256073,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11244","display_name":"Climate Change and Health Impacts","score":0.991100013256073,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9876999855041504,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11109","display_name":"Thermoregulation and physiological responses","score":0.9865000247955322,"subfield":{"id":"https://openalex.org/subfields/2737","display_name":"Physiology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8350959420204163},{"id":"https://openalex.org/keywords/shock","display_name":"Shock (circulatory)","score":0.6894721984863281},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.6609413027763367},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.49702098965644836},{"id":"https://openalex.org/keywords/the-internet","display_name":"The Internet","score":0.46875548362731934},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4115484654903412},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2406896948814392},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.2237493395805359},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.189207524061203},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.1576281487941742}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8350959420204163},{"id":"https://openalex.org/C2781300812","wikidata":"https://www.wikidata.org/wiki/Q178061","display_name":"Shock (circulatory)","level":2,"score":0.6894721984863281},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6609413027763367},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.49702098965644836},{"id":"https://openalex.org/C110875604","wikidata":"https://www.wikidata.org/wiki/Q75","display_name":"The Internet","level":2,"score":0.46875548362731934},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4115484654903412},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2406896948814392},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2237493395805359},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.189207524061203},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.1576281487941742},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/uic-atc.2017.8397436","is_oa":false,"landing_page_url":"https://doi.org/10.1109/uic-atc.2017.8397436","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE SmartWorld, Ubiquitous Intelligence &amp; Computing, Advanced &amp; Trusted Computed, Scalable Computing &amp; Communications, Cloud &amp; Big Data Computing, Internet of People and Smart City Innovation (SmartWorld/SCALCOM/UIC/ATC/CBDCom/IOP/SCI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1664633309","https://openalex.org/W1986776123","https://openalex.org/W2015800398","https://openalex.org/W2025724726","https://openalex.org/W2059178055","https://openalex.org/W2059465213","https://openalex.org/W2099982550","https://openalex.org/W2116532272","https://openalex.org/W2141175342","https://openalex.org/W2280318000","https://openalex.org/W2288501516","https://openalex.org/W2296029697","https://openalex.org/W2551424580","https://openalex.org/W2580975233","https://openalex.org/W6647084377","https://openalex.org/W6675550444"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W2900606913","https://openalex.org/W4320003279","https://openalex.org/W2326910963","https://openalex.org/W3111008797","https://openalex.org/W4287552621","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,13,23,37,87,105,148],"temperature":[4,48],"management":[5],"system":[6,70,137],"(TMS)":[7],"to":[8,72,91,140],"prevent":[9,41,92],"heat":[10,42,96],"shock":[11,21,43],"in":[12,29,44,147],"house":[14],"using":[15,77,110],"Internet":[16],"of":[17,95,102,127],"Things":[18],"technology.":[19],"Heat":[20],"is":[22,50,61,83,138],"serious":[24],"problem":[25],"for":[26,113],"elderly":[27],"people":[28],"Japan,":[30],"particularly":[31],"those":[32],"with":[33],"heart":[34],"disease":[35],"or":[36],"cerebral":[38],"infarction.":[39],"To":[40,98,119],"the":[45,53,63,73,81,93,100,117,121,123,128,136],"home,":[46],"stable":[47,142],"control":[49],"necessary.":[51],"Therefore,":[52],"proposed":[54],"TMS":[55],"implements":[56],"two":[57,111,114],"main":[58],"functions:":[59],"one":[60],"controlling":[62],"heat,":[64],"ventilation,":[65],"and":[66,80,125,150],"air":[67],"conditioning":[68],"(HVAC)":[69],"according":[71],"collected":[74],"environmental":[75],"data":[76,124],"networked":[78],"sensors,":[79],"other":[82],"providing":[84],"information":[85],"through":[86],"webpage":[88],"instructing":[89],"how":[90],"effects":[94],"shock.":[97],"test":[99],"applicability":[101],"this":[103],"system,":[104,122],"feasibility":[106],"study":[107],"was":[108],"conducted":[109],"households":[112],"weeks":[115],"during":[116],"winter.":[118],"evaluate":[120],"impressions":[126],"users":[129],"were":[130],"collected.":[131],"The":[132],"results":[133],"show":[134],"that":[135],"able":[139],"maintain":[141],"temperatures":[143],"between":[144],"different":[145],"rooms":[146],"home":[149],"provide":[151],"useful":[152],"information.":[153]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
