{"id":"https://openalex.org/W7127308893","doi":"https://doi.org/10.1109/tsg.2026.3660273","title":"Data-Driven Microgrid Operation Toward Optimized Battery Energy Storage Lifetime Degradation","display_name":"Data-Driven Microgrid Operation Toward Optimized Battery Energy Storage Lifetime Degradation","publication_year":2026,"publication_date":"2026-02-03","ids":{"openalex":"https://openalex.org/W7127308893","doi":"https://doi.org/10.1109/tsg.2026.3660273"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2026.3660273","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2026.3660273","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5121517937","display_name":"Xizhen Xue","orcid":null},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Xizhen Xue","raw_affiliation_strings":["Center for Power Engineering (CPE), School of Electrical and Electronic Engineering, Nanyang Technological University, Nanyang Ave, Singapore"],"raw_orcid":"https://orcid.org/0000-0002-0413-6496","affiliations":[{"raw_affiliation_string":"Center for Power Engineering (CPE), School of Electrical and Electronic Engineering, Nanyang Technological University, Nanyang Ave, Singapore","institution_ids":["https://openalex.org/I172675005"]}]},{"author_position":"last","author":{"id":null,"display_name":"Yan Xu","orcid":"https://orcid.org/0000-0002-0503-183X"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Yan Xu","raw_affiliation_strings":["Center for Power Engineering (CPE), School of Electrical and Electronic Engineering, Nanyang Technological University, Nanyang Ave, Singapore"],"raw_orcid":"https://orcid.org/0000-0002-0503-183X","affiliations":[{"raw_affiliation_string":"Center for Power Engineering (CPE), School of Electrical and Electronic Engineering, Nanyang Technological University, Nanyang Ave, Singapore","institution_ids":["https://openalex.org/I172675005"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I172675005"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.10426288,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"17","issue":"4","first_page":"2682","last_page":"2692"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.70169997215271,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.70169997215271,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.250900000333786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.008299999870359898,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8633000254631042},{"id":"https://openalex.org/keywords/degradation","display_name":"Degradation (telecommunications)","score":0.6603000164031982},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.5174999833106995},{"id":"https://openalex.org/keywords/dynamic-programming","display_name":"Dynamic programming","score":0.5135999917984009},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.4997999966144562},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.46630001068115234},{"id":"https://openalex.org/keywords/convex-optimization","display_name":"Convex optimization","score":0.44429999589920044},{"id":"https://openalex.org/keywords/constraint","display_name":"Constraint (computer-aided design)","score":0.4422000050544739},{"id":"https://openalex.org/keywords/function","display_name":"Function (biology)","score":0.3944000005722046}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8633000254631042},{"id":"https://openalex.org/C2779679103","wikidata":"https://www.wikidata.org/wiki/Q5251805","display_name":"Degradation (telecommunications)","level":2,"score":0.6603000164031982},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.5174999833106995},{"id":"https://openalex.org/C37404715","wikidata":"https://www.wikidata.org/wiki/Q380679","display_name":"Dynamic programming","level":2,"score":0.5135999917984009},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5054000020027161},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.4997999966144562},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.48489999771118164},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.46630001068115234},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4634999930858612},{"id":"https://openalex.org/C157972887","wikidata":"https://www.wikidata.org/wiki/Q463359","display_name":"Convex optimization","level":3,"score":0.44429999589920044},{"id":"https://openalex.org/C2776036281","wikidata":"https://www.wikidata.org/wiki/Q48769818","display_name":"Constraint (computer-aided design)","level":2,"score":0.4422000050544739},{"id":"https://openalex.org/C14036430","wikidata":"https://www.wikidata.org/wiki/Q3736076","display_name":"Function (biology)","level":2,"score":0.3944000005722046},{"id":"https://openalex.org/C2776582896","wikidata":"https://www.wikidata.org/wiki/Q5368536","display_name":"State of charge","level":4,"score":0.3772999942302704},{"id":"https://openalex.org/C41045048","wikidata":"https://www.wikidata.org/wiki/Q202843","display_name":"Linear programming","level":2,"score":0.37299999594688416},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.37070000171661377},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.36390000581741333},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.36079999804496765},{"id":"https://openalex.org/C2780106510","wikidata":"https://www.wikidata.org/wiki/Q4822597","display_name":"Depth of discharge","level":4,"score":0.3375000059604645},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.31610000133514404},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30390000343322754},{"id":"https://openalex.org/C116219307","wikidata":"https://www.wikidata.org/wiki/Q7236625","display_name":"Power system simulation","level":4,"score":0.2842000126838684},{"id":"https://openalex.org/C146357865","wikidata":"https://www.wikidata.org/wiki/Q1123245","display_name":"Stage (stratigraphy)","level":2,"score":0.27570000290870667},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.27300000190734863},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.27239999175071716},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.26489999890327454},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.26429998874664307},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.2630000114440918},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.2540999948978424},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2533000111579895},{"id":"https://openalex.org/C194739806","wikidata":"https://www.wikidata.org/wiki/Q66221","display_name":"Computer data storage","level":2,"score":0.250900000333786}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2026.3660273","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2026.3660273","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:dr.ntu.edu.sg:10356/212138","is_oa":false,"landing_page_url":"https://hdl.handle.net/10356/212138","pdf_url":null,"source":{"id":"https://openalex.org/S4306402609","display_name":"DR-NTU (Nanyang Technological University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I172675005","host_organization_name":"Nanyang Technological University","host_organization_lineage":["https://openalex.org/I172675005"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8710030913352966,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,11,52,60,112,143],"new":[4],"data-driven":[5],"approach":[6],"for":[7,69,122],"two-stage":[8],"operation":[9,77,99],"of":[10,41,110,149],"microgrid":[12],"(MG)":[13],"towards":[14],"optimized":[15],"battery":[16],"energy":[17],"storage":[18],"(BES)":[19],"lifetime":[20,72],"degradation.":[21],"At":[22,82],"the":[23,27,32,75,83,97,106,147,150],"first":[24],"stage":[25,85],"(day-ahead),":[26],"BES":[28,47,54,71,126],"degradation":[29,48,73],"range":[30],"over":[31],"scheduled":[33],"day":[34],"is":[35,57,67,92,120],"optimally":[36],"allocated":[37],"under":[38,49,138],"day-ahead":[39],"forecast":[40],"random":[42],"variables.":[43],"To":[44],"accurately":[45],"quantify":[46],"temperature":[50,107],"impact,":[51],"convex":[53],"electrothermal-aging":[55],"model":[56,62],"constructed.":[58],"Then,":[59],"dynamic":[61,89],"constraint":[63],"coefficient":[64],"determination":[65],"method":[66,91,119],"proposed":[68,151],"optimizing":[70],"using":[74],"historical":[76],"and":[78,130],"updated":[79],"current":[80],"information.":[81],"second":[84],"(real-time),":[86],"an":[87],"approximate":[88],"programming":[90],"developed":[93],"to":[94],"real-time":[95],"optimize":[96],"MG":[98,144],"after":[100],"multiple":[101],"uncertainties":[102],"are":[103],"realized.":[104],"Considering":[105],"dependent":[108],"constraints":[109],"BES,":[111],"sequential":[113],"decomposed":[114],"value":[115],"function":[116],"slope":[117],"update":[118],"designed":[121],"enhanced":[123],"optimization":[124],"feasibility,":[125],"aging":[127],"quantification":[128],"accuracy,":[129],"training":[131],"efficacy,":[132],"which":[133],"can":[134],"deliver":[135],"high-quality":[136],"solutions":[137],"uncertainties.":[139],"Case":[140],"studies":[141],"on":[142],"system":[145],"demonstrate":[146],"effectiveness":[148],"approach.":[152]},"counts_by_year":[],"updated_date":"2026-06-24T06:17:17.354583","created_date":"2026-02-04T00:00:00"}
