{"id":"https://openalex.org/W7123344858","doi":"https://doi.org/10.1109/tsg.2026.3653574","title":"Robust Coordination of Preventive and Corrective Security Control for a Multi-Energy Microgrid With Multiple Demand Response Participation","display_name":"Robust Coordination of Preventive and Corrective Security Control for a Multi-Energy Microgrid With Multiple Demand Response Participation","publication_year":2026,"publication_date":"2026-01-12","ids":{"openalex":"https://openalex.org/W7123344858","doi":"https://doi.org/10.1109/tsg.2026.3653574"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2026.3653574","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2026.3653574","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Yan Cao","orcid":"https://orcid.org/0009-0005-8507-4248"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Yan Cao","raw_affiliation_strings":["Center for Power Engineering, School of Electrical and Electronic Engineering, Nanyang Technological University, Jurong West, Singapore"],"raw_orcid":"https://orcid.org/0009-0005-8507-4248","affiliations":[{"raw_affiliation_string":"Center for Power Engineering, School of Electrical and Electronic Engineering, Nanyang Technological University, Jurong West, Singapore","institution_ids":["https://openalex.org/I172675005"]}]},{"author_position":"last","author":{"id":null,"display_name":"Yan Xu","orcid":"https://orcid.org/0000-0002-0503-183X"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Yan Xu","raw_affiliation_strings":["Center for Power Engineering, School of Electrical and Electronic Engineering, Nanyang Technological University, Jurong West, Singapore"],"raw_orcid":"https://orcid.org/0000-0002-0503-183X","affiliations":[{"raw_affiliation_string":"Center for Power Engineering, School of Electrical and Electronic Engineering, Nanyang Technological University, Jurong West, Singapore","institution_ids":["https://openalex.org/I172675005"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I172675005"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.03541557,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"17","issue":"4","first_page":"3017","last_page":"3031"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.4424999952316284,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.4424999952316284,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.2531000077724457,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.12449999898672104,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8234000205993652},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.7786999940872192},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.6596999764442444},{"id":"https://openalex.org/keywords/contingency","display_name":"Contingency","score":0.6097000241279602},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.5085999965667725},{"id":"https://openalex.org/keywords/exploit","display_name":"Exploit","score":0.4205999970436096},{"id":"https://openalex.org/keywords/robust-optimization","display_name":"Robust optimization","score":0.4205999970436096},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3799000084400177}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8234000205993652},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.7786999940872192},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.6596999764442444},{"id":"https://openalex.org/C97508593","wikidata":"https://www.wikidata.org/wiki/Q1359069","display_name":"Contingency","level":2,"score":0.6097000241279602},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5194000005722046},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.5085999965667725},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.48429998755455017},{"id":"https://openalex.org/C165696696","wikidata":"https://www.wikidata.org/wiki/Q11287","display_name":"Exploit","level":2,"score":0.4205999970436096},{"id":"https://openalex.org/C193254401","wikidata":"https://www.wikidata.org/wiki/Q2160088","display_name":"Robust optimization","level":2,"score":0.4205999970436096},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3799000084400177},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.362199991941452},{"id":"https://openalex.org/C178148461","wikidata":"https://www.wikidata.org/wiki/Q1632136","display_name":"Security controls","level":3,"score":0.3614000082015991},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3312999904155731},{"id":"https://openalex.org/C2776098794","wikidata":"https://www.wikidata.org/wiki/Q6663315","display_name":"Load regulation","level":3,"score":0.32409998774528503},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.32249999046325684},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.31200000643730164},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.2989000082015991},{"id":"https://openalex.org/C2780069185","wikidata":"https://www.wikidata.org/wiki/Q7977945","display_name":"Equivalence (formal languages)","level":2,"score":0.28870001435279846},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.2775999903678894},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.2757999897003174},{"id":"https://openalex.org/C3017997152","wikidata":"https://www.wikidata.org/wiki/Q814610","display_name":"Emergency response","level":2,"score":0.27239999175071716},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2651999890804291},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.2621999979019165},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.2597000002861023}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2026.3653574","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2026.3653574","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:dr.ntu.edu.sg:10356/212546","is_oa":false,"landing_page_url":"https://hdl.handle.net/10356/212546","pdf_url":null,"source":{"id":"https://openalex.org/S4306402609","display_name":"DR-NTU (Nanyang Technological University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I172675005","host_organization_name":"Nanyang Technological University","host_organization_lineage":["https://openalex.org/I172675005"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.5088046193122864}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"To":[0,90],"enhance":[1],"the":[2,73,86,93,96,147,178],"operational":[3],"security":[4,87],"of":[5,47,95,150,177],"a":[6,16,37,64,137,157,162,184],"multi-energy":[7,48,100],"microgrid":[8],"(MEMG)":[9],"under":[10,82],"contingency":[11,61,158,166],"events,":[12],"this":[13],"paper":[14],"proposes":[15],"new":[17],"method":[18,160,180],"to":[19,71,145],"robustly":[20],"coordinate":[21],"preventive":[22],"control":[23,27,88,141],"(PC)":[24],"and":[25,44,50,53,60,79,102,153,161,175,191],"corrective":[26],"(CC)":[28],"actions":[29,81],"with":[30,113,123,187],"multiple":[31],"demand":[32],"response":[33,148],"(DR)":[34],"participation.":[35],"Firstly,":[36],"coordination":[38,75],"framework":[39],"is":[40,69,117,128,143],"designed":[41],"for":[42],"pre-contingency":[43,131],"emergency":[45,139],"DR":[46,132,152],"loads":[49,122],"other":[51],"PC":[52,78],"CC":[54,80],"measures":[55],"across":[56],"day-ahead,":[57],"intra-day":[58],"normal":[59],"stages.":[62],"Then,":[63],"robust":[65],"optimization":[66],"(RO)":[67],"model":[68,112,142],"formulated":[70],"determine":[72],"optimal":[74],"between":[76],"those":[77],"uncertainties,":[83],"while":[84],"minimizing":[85],"costs.":[89],"better":[91],"characterize":[92],"effect":[94],"thermal":[97,110,124,193],"carrier":[98],"in":[99,130],"coupling":[101],"supply":[103],"changes":[104],"during":[105],"failures,":[106],"an":[107],"energy":[108],"flow-based":[109],"network":[111],"association":[114],"matrix":[115],"modification":[116],"proposed.":[118],"For":[119],"space":[120],"heating":[121],"inertia,":[125],"temperature":[126],"regulation":[127],"employed":[129],"considering":[133],"consumer":[134],"comfort.":[135],"Further,":[136],"ladder-type":[138],"load":[140,154],"developed":[144],"exploit":[146],"potential":[149],"incentive-based":[151],"shedding.":[155],"Finally,":[156],"screening":[159],"column-and-constraint":[163],"generation-embedded":[164],"sequential":[165],"augmentation":[167],"(CCG-SCA)":[168],"solution":[169],"algorithm":[170],"are":[171,181],"designed.":[172],"The":[173],"effectiveness":[174],"robustness":[176],"proposed":[179],"verified":[182],"on":[183],"MEMG":[185],"system":[186],"33":[188],"electric":[189],"buses":[190],"24":[192],"nodes.":[194]},"counts_by_year":[],"updated_date":"2026-06-24T06:17:17.354583","created_date":"2026-01-14T00:00:00"}
