{"id":"https://openalex.org/W4415821167","doi":"https://doi.org/10.1109/tsg.2025.3628268","title":"Dynamic Load Restoration of Coupled Power-Transportation Systems Considering Healthcare System Operation","display_name":"Dynamic Load Restoration of Coupled Power-Transportation Systems Considering Healthcare System Operation","publication_year":2025,"publication_date":"2025-11-03","ids":{"openalex":"https://openalex.org/W4415821167","doi":"https://doi.org/10.1109/tsg.2025.3628268"},"language":null,"primary_location":{"id":"doi:10.1109/tsg.2025.3628268","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3628268","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103784020","display_name":"Meng Yang","orcid":"https://orcid.org/0009-0000-0965-2003"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"HK","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["HK"],"is_corresponding":true,"raw_author_name":"Meng Yang","raw_affiliation_strings":["Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China","Department of Mechanical and Automation Engineering, Chinese University of Hong Kong, Hong Kong, China"],"raw_orcid":"https://orcid.org/0009-0000-0965-2003","affiliations":[{"raw_affiliation_string":"Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]},{"raw_affiliation_string":"Department of Mechanical and Automation Engineering, Chinese University of Hong Kong, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101733552","display_name":"Han Wang","orcid":"https://orcid.org/0000-0002-7335-0947"},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Han Wang","raw_affiliation_strings":["Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China","Ministry of Education, Key Laboratory of Control of Power Transmission and Conversion, Shanghai Jiao Tong University, Shanghai, China"],"raw_orcid":"https://orcid.org/0000-0002-7335-0947","affiliations":[{"raw_affiliation_string":"Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]},{"raw_affiliation_string":"Ministry of Education, Key Laboratory of Control of Power Transmission and Conversion, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059408070","display_name":"Yin Xu","orcid":"https://orcid.org/0000-0002-0945-9024"},"institutions":[{"id":"https://openalex.org/I21193070","display_name":"Beijing Jiaotong University","ror":"https://ror.org/01yj56c84","country_code":"CN","type":"education","lineage":["https://openalex.org/I21193070"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yin Xu","raw_affiliation_strings":["School of Electrical Engineering, Beijing Jiaotong University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-0945-9024","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Beijing Jiaotong University, Beijing, China","institution_ids":["https://openalex.org/I21193070"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100454821","display_name":"Yue Chen","orcid":"https://orcid.org/0000-0002-7594-7587"},"institutions":[{"id":"https://openalex.org/I177725633","display_name":"Chinese University of Hong Kong","ror":"https://ror.org/00t33hh48","country_code":"HK","type":"education","lineage":["https://openalex.org/I177725633"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Yue Chen","raw_affiliation_strings":["Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China","Department of Mechanical and Automation Engineering, Chinese University of Hong Kong, Hong Kong, China"],"raw_orcid":"https://orcid.org/0000-0002-7594-7587","affiliations":[{"raw_affiliation_string":"Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]},{"raw_affiliation_string":"Department of Mechanical and Automation Engineering, Chinese University of Hong Kong, Hong Kong, China","institution_ids":["https://openalex.org/I177725633"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5103784020"],"corresponding_institution_ids":["https://openalex.org/I177725633"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.32147494,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"17","issue":"2","first_page":"1093","last_page":"1107"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11807","display_name":"Infrastructure Resilience and Vulnerability Analysis","score":0.49399998784065247,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11807","display_name":"Infrastructure Resilience and Vulnerability Analysis","score":0.49399998784065247,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.3165999948978424,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.02710000053048134,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5723999738693237},{"id":"https://openalex.org/keywords/healthcare-system","display_name":"Healthcare system","score":0.4869000017642975},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.4523000121116638},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.4438999891281128},{"id":"https://openalex.org/keywords/health-care","display_name":"Health care","score":0.42899999022483826},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.421099990606308},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.40119999647140503},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3944000005722046}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5723999738693237},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5619000196456909},{"id":"https://openalex.org/C2988170871","wikidata":"https://www.wikidata.org/wiki/Q11000047","display_name":"Healthcare system","level":3,"score":0.4869000017642975},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.484499990940094},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4587000012397766},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.4523000121116638},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.4438999891281128},{"id":"https://openalex.org/C160735492","wikidata":"https://www.wikidata.org/wiki/Q31207","display_name":"Health care","level":2,"score":0.42899999022483826},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.421099990606308},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.40119999647140503},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3944000005722046},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.3815000057220459},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38040000200271606},{"id":"https://openalex.org/C3018457447","wikidata":"https://www.wikidata.org/wiki/Q31207","display_name":"Healthcare delivery","level":3,"score":0.3375999927520752},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3303999900817871},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.3248000144958496},{"id":"https://openalex.org/C3018653863","wikidata":"https://www.wikidata.org/wiki/Q5281355","display_name":"Disaster response","level":3,"score":0.31679999828338623},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.30790001153945923},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.29330000281333923},{"id":"https://openalex.org/C24119478","wikidata":"https://www.wikidata.org/wiki/Q679871","display_name":"Systems analysis","level":2,"score":0.28999999165534973},{"id":"https://openalex.org/C184773241","wikidata":"https://www.wikidata.org/wiki/Q387400","display_name":"Mains electricity","level":3,"score":0.2831000089645386},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.2806999981403351},{"id":"https://openalex.org/C146733006","wikidata":"https://www.wikidata.org/wiki/Q676081","display_name":"Electricity market","level":3,"score":0.2669000029563904},{"id":"https://openalex.org/C2776190866","wikidata":"https://www.wikidata.org/wiki/Q1341477","display_name":"Energy supply","level":3,"score":0.2632000148296356},{"id":"https://openalex.org/C19527686","wikidata":"https://www.wikidata.org/wiki/Q1665453","display_name":"System integration","level":2,"score":0.2612999975681305},{"id":"https://openalex.org/C62555980","wikidata":"https://www.wikidata.org/wiki/Q1460420","display_name":"Emergency management","level":2,"score":0.2531000077724457}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2025.3628268","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3628268","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G6044444080","display_name":null,"funder_award_id":"001/2024/SKL","funder_id":"https://openalex.org/F4320315893","funder_display_name":"VNU Science and Technology Development Fund"},{"id":"https://openalex.org/G7224379184","display_name":null,"funder_award_id":"52277072","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320315893","display_name":"VNU Science and Technology Development Fund","ror":"https://ror.org/044vr6g03"},{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0],"interdependence":[1],"of":[2,20,37,46,52,70,126,160],"power":[3,94],"and":[4,14,48,77,95,144,152,158],"transportation":[5,53,96],"systems":[6,23,39,151],"tightens":[7],"over":[8],"time,":[9],"which":[10],"brings":[11],"significant":[12],"chances":[13],"challenges":[15],"to":[16,61,65,88,114,140],"the":[17,34,43,49,68,116,124,136,156,161],"coordinated":[18],"restoration":[19,63,125,145],"coupled":[21,127],"power-transportation":[22,71,128],"under":[24,92],"extreme":[25],"weather":[26],"events.":[27],"As":[28],"a":[29,100,107],"particularly":[30],"essential":[31],"social":[32],"infrastructure,":[33],"emergency":[35,137],"response":[36],"healthcare":[38,80,131],"relies":[40],"both":[41],"on":[42,149],"adequate":[44],"supply":[45],"electricity":[47],"smooth":[50],"operation":[51,69],"systems.":[54],"This":[55,134],"paper":[56],"proposes":[57],"an":[58],"innovative":[59],"framework":[60],"dispatch":[62],"resources":[64],"quickly":[66],"recover":[67],"systems,":[72,129],"while":[73],"considering":[74,130],"patient":[75],"delivery":[76],"treatment":[78],"for":[79],"system":[81,132],"operation.":[82,133],"A":[83],"multi-time-section":[84],"approach":[85],"is":[86,112],"proposed":[87,162],"enable":[89],"real-time":[90],"decision-making":[91],"dynamic":[93],"network":[97],"conditions.":[98],"Additionally,":[99],"moment-independent":[101],"global":[102],"sensitivity":[103],"analysis":[104],"method":[105],"using":[106],"machine":[108],"learning-based":[109],"surrogate":[110],"model":[111],"developed":[113],"identify":[115],"critical":[117],"uncertain":[118],"factors":[119],"that":[120],"most":[121],"significantly":[122],"impact":[123],"enables":[135],"command":[138],"center":[139],"make":[141],"informed":[142],"preventive":[143],"strategies.":[146],"Numerical":[147],"studies":[148],"IEEE":[150],"real-world":[153],"data":[154],"demonstrate":[155],"effectiveness":[157],"practicability":[159],"framework.":[163]},"counts_by_year":[],"updated_date":"2026-02-21T06:11:54.161237","created_date":"2025-11-03T00:00:00"}
