{"id":"https://openalex.org/W4413125732","doi":"https://doi.org/10.1109/tsg.2025.3596767","title":"A Method for Identifying the Medium-Voltage Phase-to-Phase Short-Circuit Fault Section in Active Distribution Networks Based on the Equivalent Impedance Ratio of Low-Voltage Monitoring Nodes","display_name":"A Method for Identifying the Medium-Voltage Phase-to-Phase Short-Circuit Fault Section in Active Distribution Networks Based on the Equivalent Impedance Ratio of Low-Voltage Monitoring Nodes","publication_year":2025,"publication_date":"2025-08-07","ids":{"openalex":"https://openalex.org/W4413125732","doi":"https://doi.org/10.1109/tsg.2025.3596767"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2025.3596767","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3596767","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005137637","display_name":"Zhihua Zhang","orcid":"https://orcid.org/0000-0001-6111-4552"},"institutions":[{"id":"https://openalex.org/I4210162190","display_name":"China University of Petroleum, East China","ror":"https://ror.org/05gbn2817","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210162190"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhihua Zhang","raw_affiliation_strings":["College of New Energy, China University of Petroleum (East China), Qingdao, China","College of New Energy, China University of Petroleum East China, Qingdao, China"],"raw_orcid":"https://orcid.org/0000-0001-6111-4552","affiliations":[{"raw_affiliation_string":"College of New Energy, China University of Petroleum (East China), Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]},{"raw_affiliation_string":"College of New Energy, China University of Petroleum East China, Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073726909","display_name":"Shi Haojie","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162190","display_name":"China University of Petroleum, East China","ror":"https://ror.org/05gbn2817","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210162190"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haojie Shi","raw_affiliation_strings":["College of New Energy, China University of Petroleum (East China), Qingdao, China","College of New Energy, China University of Petroleum East China, Qingdao, China"],"raw_orcid":"https://orcid.org/0009-0007-5086-7744","affiliations":[{"raw_affiliation_string":"College of New Energy, China University of Petroleum (East China), Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]},{"raw_affiliation_string":"College of New Energy, China University of Petroleum East China, Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064131211","display_name":"Guang Li","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162190","display_name":"China University of Petroleum, East China","ror":"https://ror.org/05gbn2817","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210162190"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guang Li","raw_affiliation_strings":["College of New Energy, China University of Petroleum (East China), Qingdao, China","College of New Energy, China University of Petroleum East China, Qingdao, China"],"raw_orcid":"https://orcid.org/0000-0002-9132-6035","affiliations":[{"raw_affiliation_string":"College of New Energy, China University of Petroleum (East China), Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]},{"raw_affiliation_string":"College of New Energy, China University of Petroleum East China, Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112999310","display_name":"Duhao Song","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162190","display_name":"China University of Petroleum, East China","ror":"https://ror.org/05gbn2817","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210162190"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Duhao Song","raw_affiliation_strings":["College of New Energy, China University of Petroleum (East China), Qingdao, China","College of New Energy, China University of Petroleum East China, Qingdao, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of New Energy, China University of Petroleum (East China), Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]},{"raw_affiliation_string":"College of New Energy, China University of Petroleum East China, Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101243675","display_name":"Yuxiao Xing","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162190","display_name":"China University of Petroleum, East China","ror":"https://ror.org/05gbn2817","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210162190"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yuxiao Xing","raw_affiliation_strings":["College of New Energy, China University of Petroleum (East China), Qingdao, China","College of New Energy, China University of Petroleum East China, Qingdao, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of New Energy, China University of Petroleum (East China), Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]},{"raw_affiliation_string":"College of New Energy, China University of Petroleum East China, Qingdao, China","institution_ids":["https://openalex.org/I4210162190"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103582173","display_name":"Bingyin Xu","orcid":"https://orcid.org/0000-0003-4084-7137"},"institutions":[{"id":"https://openalex.org/I119203015","display_name":"Shandong University of Technology","ror":"https://ror.org/02mr3ar13","country_code":"CN","type":"education","lineage":["https://openalex.org/I119203015"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bingyin Xu","raw_affiliation_strings":["College of Electrical and Electronic Engineering, Shangdong University of Technology, Zibo, China"],"raw_orcid":"https://orcid.org/0000-0003-4084-7137","affiliations":[{"raw_affiliation_string":"College of Electrical and Electronic Engineering, Shangdong University of Technology, Zibo, China","institution_ids":["https://openalex.org/I119203015"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111953389","display_name":"Hongjie Wu","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongjie Wu","raw_affiliation_strings":["Electricity Maintenance Department, Luliang Power Supply Company of State Grid Shanxi Power Company, Shanxi, China","Luliang Power Supply Company of State Grid Shanxi Power Company, Shanxi, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electricity Maintenance Department, Luliang Power Supply Company of State Grid Shanxi Power Company, Shanxi, China","institution_ids":["https://openalex.org/I17442442","https://openalex.org/I4210126065"]},{"raw_affiliation_string":"Luliang Power Supply Company of State Grid Shanxi Power Company, Shanxi, China","institution_ids":["https://openalex.org/I17442442"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7779,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.737127,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":"16","issue":"6","first_page":"4534","last_page":"4548"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.9843999743461609,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.6125604510307312},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5560991764068604},{"id":"https://openalex.org/keywords/equivalent-circuit","display_name":"Equivalent circuit","score":0.5176306366920471},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5048032999038696},{"id":"https://openalex.org/keywords/phase","display_name":"Phase (matter)","score":0.4869047701358795},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4326311945915222},{"id":"https://openalex.org/keywords/three-phase","display_name":"Three-phase","score":0.4175671935081482},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.41246452927589417},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.34068846702575684},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3281300663948059},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.18583014607429504}],"concepts":[{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6125604510307312},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5560991764068604},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.5176306366920471},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5048032999038696},{"id":"https://openalex.org/C44280652","wikidata":"https://www.wikidata.org/wiki/Q104837","display_name":"Phase (matter)","level":2,"score":0.4869047701358795},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4326311945915222},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.4175671935081482},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41246452927589417},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.34068846702575684},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3281300663948059},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18583014607429504},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2025.3596767","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3596767","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G3569408050","display_name":null,"funder_award_id":"51977220","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G4404688054","display_name":null,"funder_award_id":"51177096","funder_id":"https://openalex.org/F4320324174","funder_display_name":"Natural Science Foundation of Shandong Province"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320324174","display_name":"Natural Science Foundation of Shandong Province","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W2007409733","https://openalex.org/W2014243485","https://openalex.org/W2031585040","https://openalex.org/W2104552536","https://openalex.org/W2155097356","https://openalex.org/W2225175383","https://openalex.org/W2246790892","https://openalex.org/W2724765071","https://openalex.org/W2793352959","https://openalex.org/W2796814646","https://openalex.org/W2935101917","https://openalex.org/W2945308371","https://openalex.org/W2945718086","https://openalex.org/W2957542766","https://openalex.org/W2982121376","https://openalex.org/W2998428013","https://openalex.org/W3010028941","https://openalex.org/W3017178695","https://openalex.org/W3093042192","https://openalex.org/W3118467535","https://openalex.org/W3136923955","https://openalex.org/W3209280283","https://openalex.org/W4224989792","https://openalex.org/W4225357732","https://openalex.org/W4283031767","https://openalex.org/W4312943755","https://openalex.org/W4313531337","https://openalex.org/W4380373459","https://openalex.org/W4387388427","https://openalex.org/W4394616122","https://openalex.org/W4399322046","https://openalex.org/W4399877955","https://openalex.org/W4400520054"],"related_works":["https://openalex.org/W2542439796","https://openalex.org/W2356048238","https://openalex.org/W2128309414","https://openalex.org/W4224288062","https://openalex.org/W3128753656","https://openalex.org/W2015676400","https://openalex.org/W2040841734","https://openalex.org/W2117283676","https://openalex.org/W2393144863","https://openalex.org/W1942874006"],"abstract_inverted_index":{"Distributed":[0],"generation":[1],"(DG)":[2],"integration":[3],"into":[4],"distribution":[5,16,37,47,122],"networks":[6,123],"brings":[7],"new":[8,30],"challenges":[9],"to":[10,83],"fault":[11,34,118,184],"location":[12,35],"in":[13,36,46,141],"medium-voltage":[14],"(MV)":[15],"networks.":[17,38],"The":[18],"popular":[19],"smart":[20],"fusion":[21],"terminals":[22],"on":[23,125,154],"the":[24,50,70,73,80,84,89,99,115,126,134,148,160],"low-voltage":[25],"(LV)":[26],"transformer":[27,182,186],"area":[28],"provide":[29],"data":[31,192],"support":[32],"for":[33,42,96,113,137],"In":[39],"this":[40,155,165],"study,":[41],"phase-to-phase":[43,116,138],"short-circuit":[44,81,117,139],"faults":[45,140],"networks,":[48],"first,":[49],"mapping":[51],"relationship":[52],"between":[53],"LV":[54,59,104],"line":[55,105],"voltage":[56,65,106],"at":[57],"each":[58,76],"monitoring":[60,77],"node":[61,78],"and":[62,79,93,147,176,193,196],"MV":[63,121],"phase":[64],"sequence":[66],"components":[67],"is":[68,86,108,131,145,157,167],"analyzed,":[69],"ratio":[71,102,128],"of":[72,120,150,178,201],"impedances":[74],"from":[75],"point":[82],"system":[85],"defined":[87],"as":[88,173],"equivalent":[90,100],"impedance":[91,101,127],"ratio,":[92],"a":[94,111,198],"method":[95,112,156,166],"inversely":[97],"calculating":[98],"using":[103],"amplitude":[107],"proposed.":[109,132],"Second,":[110],"identifying":[114],"section":[119],"based":[124],"change":[129],"characteristics":[130,153],"Next,":[133],"analysis":[135],"model":[136],"systems":[142],"containing":[143],"DG":[144],"established,":[146],"influence":[149],"its":[151],"output":[152],"analyzed.":[158],"Finally,":[159],"simulating":[161],"results":[162],"show":[163],"that":[164],"not":[168],"affected":[169],"by":[170],"factors":[171],"such":[172],"access":[174],"locations":[175],"capacity":[177],"DG,":[179],"simultaneous":[180],"faults,":[181],"connections,":[183],"resistance,":[185],"transmission":[187],"error,":[188,190],"measurement":[189],"asynchronous":[191],"load":[194],"size":[195],"has":[197],"certain":[199],"degree":[200],"robustness.":[202]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2025-12-28T23:10:05.387466","created_date":"2025-10-10T00:00:00"}
