{"id":"https://openalex.org/W4411688603","doi":"https://doi.org/10.1109/tsg.2025.3582685","title":"Energy Management for Rural Microgrid With Inaccurate Equipment Parameters: A KAN-Based Deep Reinforcement Learning Method","display_name":"Energy Management for Rural Microgrid With Inaccurate Equipment Parameters: A KAN-Based Deep Reinforcement Learning Method","publication_year":2025,"publication_date":"2025-06-26","ids":{"openalex":"https://openalex.org/W4411688603","doi":"https://doi.org/10.1109/tsg.2025.3582685"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2025.3582685","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3582685","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077967584","display_name":"Chenhao Lin","orcid":"https://orcid.org/0000-0002-9327-9260"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Chenhao Lin","raw_affiliation_strings":["School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","Harbin Institute of Technology, Harbin, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]},{"raw_affiliation_string":"Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100755964","display_name":"Ying Xu","orcid":"https://orcid.org/0000-0002-2401-7718"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ying Xu","raw_affiliation_strings":["School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","Harbin Institute of Technology, Harbin, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]},{"raw_affiliation_string":"Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012894240","display_name":"Zhongkai Yi","orcid":"https://orcid.org/0000-0003-2363-1123"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhongkai Yi","raw_affiliation_strings":["School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","Harbin Institute of Technology, Harbin, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]},{"raw_affiliation_string":"Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079493323","display_name":"Zhenghong Tu","orcid":"https://orcid.org/0000-0002-2456-5618"},"institutions":[{"id":"https://openalex.org/I204983213","display_name":"Harbin Institute of Technology","ror":"https://ror.org/01yqg2h08","country_code":"CN","type":"education","lineage":["https://openalex.org/I204983213"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhenghong Tu","raw_affiliation_strings":["School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","Harbin Institute of Technology, Harbin, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]},{"raw_affiliation_string":"Harbin Institute of Technology, Harbin, China","institution_ids":["https://openalex.org/I204983213"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5077967584"],"corresponding_institution_ids":["https://openalex.org/I204983213"],"apc_list":null,"apc_paid":null,"fwci":1.4856,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.8376846,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":99},"biblio":{"volume":"16","issue":"6","first_page":"4808","last_page":"4821"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9812999963760376,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9812999963760376,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.972599983215332,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8276525735855103},{"id":"https://openalex.org/keywords/reinforcement-learning","display_name":"Reinforcement learning","score":0.7851144075393677},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.5631234049797058},{"id":"https://openalex.org/keywords/reinforcement","display_name":"Reinforcement","score":0.5293919444084167},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.484652578830719},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.44855812191963196},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.41022780537605286},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4059619903564453},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.3947376608848572},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.36700040102005005},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33782297372817993},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3336228132247925},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.25073015689849854},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17796432971954346},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1778368055820465},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.13992145657539368},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.1138608455657959}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8276525735855103},{"id":"https://openalex.org/C97541855","wikidata":"https://www.wikidata.org/wiki/Q830687","display_name":"Reinforcement learning","level":2,"score":0.7851144075393677},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.5631234049797058},{"id":"https://openalex.org/C67203356","wikidata":"https://www.wikidata.org/wiki/Q1321905","display_name":"Reinforcement","level":2,"score":0.5293919444084167},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.484652578830719},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.44855812191963196},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.41022780537605286},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4059619903564453},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3947376608848572},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.36700040102005005},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33782297372817993},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3336228132247925},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.25073015689849854},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17796432971954346},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1778368055820465},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.13992145657539368},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.1138608455657959}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2025.3582685","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3582685","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.49000000953674316,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G4275670633","display_name":null,"funder_award_id":"52407089","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":48,"referenced_works":["https://openalex.org/W2085120662","https://openalex.org/W2145339207","https://openalex.org/W2344938262","https://openalex.org/W2614034933","https://openalex.org/W2744810977","https://openalex.org/W2761199409","https://openalex.org/W2912863505","https://openalex.org/W2921361144","https://openalex.org/W2996801915","https://openalex.org/W3096894748","https://openalex.org/W3107191128","https://openalex.org/W3127995079","https://openalex.org/W3130635378","https://openalex.org/W3162079807","https://openalex.org/W3175253211","https://openalex.org/W3199589734","https://openalex.org/W3199945038","https://openalex.org/W4200306064","https://openalex.org/W4206028292","https://openalex.org/W4214562978","https://openalex.org/W4226161947","https://openalex.org/W4285138954","https://openalex.org/W4303987558","https://openalex.org/W4307059240","https://openalex.org/W4311422471","https://openalex.org/W4312244682","https://openalex.org/W4312681566","https://openalex.org/W4312705088","https://openalex.org/W4320734012","https://openalex.org/W4324290860","https://openalex.org/W4376651889","https://openalex.org/W4378195029","https://openalex.org/W4381327857","https://openalex.org/W4382119300","https://openalex.org/W4385736039","https://openalex.org/W4390122262","https://openalex.org/W4390619973","https://openalex.org/W4390630957","https://openalex.org/W4396599460","https://openalex.org/W4396993120","https://openalex.org/W4398160269","https://openalex.org/W4400116196","https://openalex.org/W4400612603","https://openalex.org/W4401598821","https://openalex.org/W4402639326","https://openalex.org/W4403312503","https://openalex.org/W4403457444","https://openalex.org/W4406366950"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2057975886","https://openalex.org/W2333017163","https://openalex.org/W2347673489","https://openalex.org/W2964937504","https://openalex.org/W2169268775","https://openalex.org/W2371966636","https://openalex.org/W2761863946","https://openalex.org/W2936487029","https://openalex.org/W2008521473"],"abstract_inverted_index":{"During":[0],"the":[1,4,15,24,109,114,128,152],"agricultural":[2],"season,":[3],"proportion":[5],"of":[6,31,38,70,78,120,127,134,141],"irrigation":[7,27],"load":[8],"in":[9,26,131],"rural":[10,49],"microgrid":[11,50],"increases":[12],"rapidly.":[13],"However,":[14],"energy":[16,45,80],"can":[17],"hardly":[18],"be":[19],"managed":[20],"effectively":[21],"due":[22],"to":[23],"surge":[25],"load,":[28],"rapid":[29],"fluctuations":[30],"renewable":[32],"energy,":[33],"and":[34,56,73,97,113,125,139],"inaccurate":[35,66],"electrical":[36],"parameters":[37],"aging":[39],"equipment.":[40],"In":[41],"this":[42],"article,":[43],"an":[44],"management":[46],"model":[47],"for":[48],"including":[51],"irrigation,":[52],"hydrogen,":[53],"electric":[54],"heating,":[55],"power":[57],"systems":[58],"is":[59,89],"proposed.":[60],"Further,":[61],"formidable":[62],"challenges":[63],"arise":[64],"from":[65],"water-electricity":[67],"conversion":[68],"coefficient":[69],"water":[71],"pump":[72],"nonconvex":[74],"dynamic":[75,115],"efficiency":[76],"function":[77],"hydrogen":[79],"storage":[81],"system.":[82],"A":[83],"deep":[84],"reinforcement":[85],"learning":[86],"(DRL)":[87],"method":[88,130],"proposed":[90],"incorporating":[91],"a":[92,98,148],"Kolmogorov-Arnold":[93],"network":[94],"(KAN)":[95],"structure":[96],"two-stage":[99],"implementation":[100],"deployment":[101],"method,":[102],"which":[103],"maintains":[104],"robustness":[105,126],"against":[106],"discrepancies":[107],"between":[108],"controlled":[110],"training":[111],"environment":[112],"application":[116],"scenario.":[117],"The":[118,137],"results":[119],"simulation":[121],"experiments":[122],"demonstrate":[123],"adaptability":[124],"KAN-based":[129,142],"handling":[132],"deviations":[133],"equipment":[135],"parameters.":[136],"effectiveness":[138],"superiority":[140],"DRL":[143],"approach":[144],"are":[145],"validated":[146],"through":[147],"comparative":[149],"analysis":[150],"with":[151],"state-of-the-art":[153],"algorithms.":[154]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
