{"id":"https://openalex.org/W4410491761","doi":"https://doi.org/10.1109/tsg.2025.3571209","title":"Advanced Circulating Current Suppression and Voltage Regulation Schemes for Different Architectures of DC Microgrid","display_name":"Advanced Circulating Current Suppression and Voltage Regulation Schemes for Different Architectures of DC Microgrid","publication_year":2025,"publication_date":"2025-05-19","ids":{"openalex":"https://openalex.org/W4410491761","doi":"https://doi.org/10.1109/tsg.2025.3571209"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2025.3571209","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3571209","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079336259","display_name":"Adil Ayub Sheikh","orcid":"https://orcid.org/0000-0001-5275-8348"},"institutions":[{"id":"https://openalex.org/I55240360","display_name":"Yeungnam University","ror":"https://ror.org/05yc6p159","country_code":"KR","type":"education","lineage":["https://openalex.org/I55240360"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Adil Ayub Sheikh","raw_affiliation_strings":["Department of Electrical Engineering, Yeungnam University, Gyeongsan, South Korea"],"raw_orcid":"https://orcid.org/0000-0001-5275-8348","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Yeungnam University, Gyeongsan, South Korea","institution_ids":["https://openalex.org/I55240360"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058634591","display_name":"Dong\u2010Choon Lee","orcid":"https://orcid.org/0000-0003-0618-7630"},"institutions":[{"id":"https://openalex.org/I55240360","display_name":"Yeungnam University","ror":"https://ror.org/05yc6p159","country_code":"KR","type":"education","lineage":["https://openalex.org/I55240360"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Dong-Choon Lee","raw_affiliation_strings":["Department of Electrical Engineering, Yeungnam University, Gyeongsan, South Korea"],"raw_orcid":"https://orcid.org/0000-0003-0618-7630","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Yeungnam University, Gyeongsan, South Korea","institution_ids":["https://openalex.org/I55240360"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5079336259"],"corresponding_institution_ids":["https://openalex.org/I55240360"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.11024647,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"16","issue":"5","first_page":"3520","last_page":"3532"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.7958492040634155},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5713660717010498},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5383191704750061},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5277053713798523},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.5137225389480591},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5017783641815186},{"id":"https://openalex.org/keywords/low-dropout-regulator","display_name":"Low-dropout regulator","score":0.45662084221839905},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4369061589241028},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.41416770219802856},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4022650718688965},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.38078033924102783},{"id":"https://openalex.org/keywords/dropout-voltage","display_name":"Dropout voltage","score":0.23109257221221924},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.21868890523910522}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7958492040634155},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5713660717010498},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5383191704750061},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5277053713798523},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5137225389480591},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5017783641815186},{"id":"https://openalex.org/C140501009","wikidata":"https://www.wikidata.org/wiki/Q6692746","display_name":"Low-dropout regulator","level":5,"score":0.45662084221839905},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4369061589241028},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41416770219802856},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4022650718688965},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38078033924102783},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.23109257221221924},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.21868890523910522},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2025.3571209","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3571209","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8299999833106995,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G5269746418","display_name":null,"funder_award_id":"RS-2024-00347621","funder_id":"https://openalex.org/F4320322120","funder_display_name":"National Research Foundation of Korea"}],"funders":[{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":30,"referenced_works":["https://openalex.org/W2025011158","https://openalex.org/W2026923967","https://openalex.org/W2064133831","https://openalex.org/W2084943452","https://openalex.org/W2127086830","https://openalex.org/W2559190328","https://openalex.org/W2797254880","https://openalex.org/W2900745374","https://openalex.org/W2923888372","https://openalex.org/W2947131274","https://openalex.org/W2965660773","https://openalex.org/W2990081414","https://openalex.org/W2991064874","https://openalex.org/W3007351633","https://openalex.org/W3045935531","https://openalex.org/W3094139955","https://openalex.org/W3119064410","https://openalex.org/W3120149568","https://openalex.org/W4200036919","https://openalex.org/W4312259984","https://openalex.org/W4312404416","https://openalex.org/W4321384686","https://openalex.org/W4361802004","https://openalex.org/W4365790442","https://openalex.org/W4385626832","https://openalex.org/W4385834554","https://openalex.org/W4390416628","https://openalex.org/W4390480860","https://openalex.org/W4393197042","https://openalex.org/W4399329586"],"related_works":["https://openalex.org/W1982997428","https://openalex.org/W2024816799","https://openalex.org/W2382804880","https://openalex.org/W1733802673","https://openalex.org/W2379548982","https://openalex.org/W2138657619","https://openalex.org/W3207918902","https://openalex.org/W3083505630","https://openalex.org/W1493009364","https://openalex.org/W1898186557"],"abstract_inverted_index":{"In":[0],"this":[1,46,72],"paper,":[2],"an":[3],"innovative":[4],"control":[5,73],"strategy":[6,20,74],"to":[7,32],"address":[8],"circulating":[9,23,79,125],"currents":[10,80,126],"for":[11],"different":[12,152],"structure":[13],"of":[14,64,93,99],"DC":[15,94],"microgrids":[16],"is":[17,53,102],"proposed.":[18],"The":[19,68,97,136],"suggests":[21],"a":[22,48,107,132],"current":[24,34],"suppression":[25],"(CCS)":[26],"controller":[27,52],"that":[28,71,113],"estimates":[29],"effective":[30],"resistances":[31],"optimize":[33],"sharing":[35],"among":[36],"multiple":[37],"sources.":[38],"To":[39],"counteract":[40],"minor":[41],"voltage":[42,85,129],"drops":[43],"caused":[44],"by":[45],"suppression,":[47],"voltagespread":[49],"compensation":[50],"(VSC)":[51],"implemented":[54],"which":[55],"dynamically":[56],"adjusts":[57],"the":[58,62,65,89,114],"voltages":[59],"based":[60],"on":[61,106],"voltage-spread":[63],"source":[66],"converters.":[67],"results":[69],"confirm":[70],"not":[75],"only":[76],"effectively":[77],"suppresses":[78],"but":[81],"also":[82,139],"significantly":[83],"enhances":[84],"regulation,":[86],"thereby":[87],"improving":[88],"stability":[90],"and":[91,127,150,155],"performance":[92],"microgrid":[95],"systems.":[96],"effectiveness":[98],"these":[100],"controllers":[101,116,137],"validated":[103],"through":[104],"experiments":[105],"5-bus,":[108],"70V":[109],"hardware":[110],"prototype,":[111],"demonstrating":[112],"proposed":[115],"can":[117],"achieve":[118],"over":[119],"99.5":[120],"%":[121,134],"accuracy":[122],"in":[123],"reducing":[124],"maintain":[128],"deviations":[130],"within":[131],"5":[133],"tolerance.":[135],"are":[138],"tested":[140],"across":[141],"various":[142],"scenarios,":[143],"including":[144],"energy":[145],"storage":[146],"system":[147,153],"(ESS)":[148],"charging":[149],"discharging,":[151],"topologies,":[154],"varying":[156],"droop":[157],"resistances.":[158]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
