{"id":"https://openalex.org/W4410358666","doi":"https://doi.org/10.1109/tsg.2025.3569696","title":"Safe Reinforcement Learning-Based Transient Stability Control for Islanded Microgrids With Topology Reconfiguration","display_name":"Safe Reinforcement Learning-Based Transient Stability Control for Islanded Microgrids With Topology Reconfiguration","publication_year":2025,"publication_date":"2025-05-14","ids":{"openalex":"https://openalex.org/W4410358666","doi":"https://doi.org/10.1109/tsg.2025.3569696"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2025.3569696","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3569696","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5066671839","display_name":"Tong Su","orcid":"https://orcid.org/0000-0002-5424-6757"},"institutions":[{"id":"https://openalex.org/I140172145","display_name":"University of Connecticut","ror":"https://ror.org/02der9h97","country_code":"US","type":"education","lineage":["https://openalex.org/I140172145"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Tong Su","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA"],"raw_orcid":"https://orcid.org/0000-0002-5424-6757","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA","institution_ids":["https://openalex.org/I140172145"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042402520","display_name":"Junbo Zhao","orcid":"https://orcid.org/0000-0002-8498-9666"},"institutions":[{"id":"https://openalex.org/I140172145","display_name":"University of Connecticut","ror":"https://ror.org/02der9h97","country_code":"US","type":"education","lineage":["https://openalex.org/I140172145"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Junbo Zhao","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA"],"raw_orcid":"https://orcid.org/0000-0002-8498-9666","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA","institution_ids":["https://openalex.org/I140172145"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5058077843","display_name":"Yiyun Yao","orcid":"https://orcid.org/0000-0003-3847-815X"},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yiyun Yao","raw_affiliation_strings":["Power System Engineering Center, National Renewable Energy Laboratory, Golden, CO, USA","National Renewable Energy Laboratory, Golden, CO, USA"],"raw_orcid":"https://orcid.org/0000-0003-3847-815X","affiliations":[{"raw_affiliation_string":"Power System Engineering Center, National Renewable Energy Laboratory, Golden, CO, USA","institution_ids":["https://openalex.org/I1297288678"]},{"raw_affiliation_string":"National Renewable Energy Laboratory, Golden, CO, USA","institution_ids":["https://openalex.org/I1297288678"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056446144","display_name":"Alaa Selim","orcid":"https://orcid.org/0000-0002-5077-5168"},"institutions":[{"id":"https://openalex.org/I140172145","display_name":"University of Connecticut","ror":"https://ror.org/02der9h97","country_code":"US","type":"education","lineage":["https://openalex.org/I140172145"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Alaa Selim","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA"],"raw_orcid":"https://orcid.org/0000-0002-5077-5168","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA","institution_ids":["https://openalex.org/I140172145"]}]},{"author_position":"last","author":{"id":null,"display_name":"Fei Ding","orcid":"https://orcid.org/0000-0002-2500-1275"},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Fei Ding","raw_affiliation_strings":["Power System Engineering Center, National Renewable Energy Laboratory, Golden, CO, USA","National Renewable Energy Laboratory, Golden, CO, USA"],"raw_orcid":"https://orcid.org/0000-0002-2500-1275","affiliations":[{"raw_affiliation_string":"Power System Engineering Center, National Renewable Energy Laboratory, Golden, CO, USA","institution_ids":["https://openalex.org/I1297288678"]},{"raw_affiliation_string":"National Renewable Energy Laboratory, Golden, CO, USA","institution_ids":["https://openalex.org/I1297288678"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":8.9212,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":{"value":0.98453688,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"16","issue":"4","first_page":"3432","last_page":"3444"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9700000286102295,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.7352844476699829},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.6330124139785767},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.6216169595718384},{"id":"https://openalex.org/keywords/reinforcement-learning","display_name":"Reinforcement learning","score":0.6154869794845581},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.5843327641487122},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5631958842277527},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5024440288543701},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.44121798872947693},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.41667240858078003},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.40090715885162354},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.15898889303207397},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.1408747434616089},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.08922532200813293},{"id":"https://openalex.org/keywords/machine-learning","display_name":"Machine learning","score":0.08146589994430542}],"concepts":[{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.7352844476699829},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6330124139785767},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.6216169595718384},{"id":"https://openalex.org/C97541855","wikidata":"https://www.wikidata.org/wiki/Q830687","display_name":"Reinforcement learning","level":2,"score":0.6154869794845581},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.5843327641487122},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5631958842277527},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5024440288543701},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.44121798872947693},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.41667240858078003},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40090715885162354},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.15898889303207397},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1408747434616089},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.08922532200813293},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.08146589994430542},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2025.3569696","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2025.3569696","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.41999998688697815,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"}],"awards":[{"id":"https://openalex.org/G2989208386","display_name":null,"funder_award_id":"TSG-01553-2024","funder_id":"https://openalex.org/F4320337712","funder_display_name":"Solar Energy Technologies Office"},{"id":"https://openalex.org/G440252240","display_name":null,"funder_award_id":"De-AC36-08-GO28308","funder_id":"https://openalex.org/F4320338290","funder_display_name":"National Renewable Energy Laboratory"},{"id":"https://openalex.org/G5439315992","display_name":null,"funder_award_id":"10422","funder_id":"https://openalex.org/F4320337712","funder_display_name":"Solar Energy Technologies Office"}],"funders":[{"id":"https://openalex.org/F4320333589","display_name":"Environmental Security Technology Certification Program","ror":null},{"id":"https://openalex.org/F4320337712","display_name":"Solar Energy Technologies Office","ror":"https://ror.org/033jmdj81"},{"id":"https://openalex.org/F4320338290","display_name":"National Renewable Energy Laboratory","ror":"https://ror.org/036266993"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":42,"referenced_works":["https://openalex.org/W1578978182","https://openalex.org/W2011393317","https://openalex.org/W2075877818","https://openalex.org/W2115856383","https://openalex.org/W2546146839","https://openalex.org/W2625248137","https://openalex.org/W2790306973","https://openalex.org/W2890688913","https://openalex.org/W2965363452","https://openalex.org/W2999463146","https://openalex.org/W3127169749","https://openalex.org/W3194280320","https://openalex.org/W3202431488","https://openalex.org/W3216581177","https://openalex.org/W4220846665","https://openalex.org/W4220863999","https://openalex.org/W4251818744","https://openalex.org/W4312420662","https://openalex.org/W4318425171","https://openalex.org/W4319302736","https://openalex.org/W4319338775","https://openalex.org/W4319996387","https://openalex.org/W4320340663","https://openalex.org/W4367280629","https://openalex.org/W4379805774","https://openalex.org/W4383340036","https://openalex.org/W4385767976","https://openalex.org/W4386432149","https://openalex.org/W4388052880","https://openalex.org/W4402402057","https://openalex.org/W6637968757","https://openalex.org/W6684770997","https://openalex.org/W6737893269","https://openalex.org/W6738492492","https://openalex.org/W6751725685","https://openalex.org/W6755463424","https://openalex.org/W6771280675","https://openalex.org/W6774576859","https://openalex.org/W6780587392","https://openalex.org/W6785187516","https://openalex.org/W6843754643","https://openalex.org/W6870124633"],"related_works":["https://openalex.org/W1981002473","https://openalex.org/W2357657342","https://openalex.org/W2153432761","https://openalex.org/W2152623100","https://openalex.org/W4214878056","https://openalex.org/W1580144672","https://openalex.org/W2142042635","https://openalex.org/W1988127757","https://openalex.org/W4248634784","https://openalex.org/W2103296973"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,29,35,49,68,100,112],"safe":[4],"reinforcement":[5],"learning":[6],"(RL)-based":[7],"transient":[8,61,69],"stability":[9,62,70],"emergency":[10,128],"control":[11,26,129],"(TSEC)":[12],"method":[13,120],"for":[14,37],"islanded":[15,114],"microgrids.":[16],"RL":[17],"requires":[18],"extensive":[19],"interaction":[20],"with":[21,94],"the":[22,57,95,106,118,126],"environment":[23,98],"to":[24,55,66,133],"learn":[25],"strategies,":[27],"hence,":[28],"data-driven":[30],"approach":[31],"is":[32,48,53],"used":[33],"as":[34],"substitute":[36],"time-consuming":[38],"time-domain":[39],"simulation":[40],"calculations.":[41],"Deep":[42],"sigma":[43],"point":[44],"processes":[45],"(DSPP),":[46],"which":[47],"Gaussian":[50],"process":[51],"model,":[52],"utilized":[54],"predict":[56],"normal":[58],"distribution":[59],"of":[60,63],"microgrids":[64],"and":[65,84,123],"construct":[67],"chance":[71],"constraint.":[72],"Reward-constrained":[73],"policy":[74,82],"optimization":[75],"(RCPO)":[76],"can":[77,121],"simultaneously":[78],"achieve":[79],"objective":[80],"prediction,":[81],"learning,":[83],"constraint":[85],"cost":[86],"coefficient":[87],"update":[88],"across":[89],"multiple":[90],"timescales.":[91],"RCPO":[92],"interacts":[93],"DSPP-based":[96],"microgrid":[97,115],"through":[99],"multi-process":[101],"parallel":[102],"manner,":[103],"greatly":[104],"increasing":[105],"training":[107],"speed.":[108],"Case":[109],"studies":[110],"on":[111],"real":[113],"demonstrate":[116],"that":[117],"proposed":[119],"efficiently":[122],"quickly":[124],"obtain":[125],"optimal":[127],"strategy":[130],"while":[131],"adhering":[132],"all":[134],"hard":[135],"constraints.":[136]},"counts_by_year":[{"year":2026,"cited_by_count":13},{"year":2025,"cited_by_count":5}],"updated_date":"2026-08-02T14:50:37.381335","created_date":"2025-10-10T00:00:00"}
