{"id":"https://openalex.org/W4405022652","doi":"https://doi.org/10.1109/tsg.2024.3509528","title":"Coordinated Planning of Transmission Network Expansion and Distribution Network Modernization With Microgrids Under Non-Uniform Discrete Choices","display_name":"Coordinated Planning of Transmission Network Expansion and Distribution Network Modernization With Microgrids Under Non-Uniform Discrete Choices","publication_year":2024,"publication_date":"2024-12-04","ids":{"openalex":"https://openalex.org/W4405022652","doi":"https://doi.org/10.1109/tsg.2024.3509528"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2024.3509528","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3509528","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5037048914","display_name":"Xutao Han","orcid":"https://orcid.org/0000-0003-2098-9082"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Xutao Han","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100779406","display_name":"Zhiyi Li","orcid":"https://orcid.org/0000-0001-7498-8005"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiyi Li","raw_affiliation_strings":["College of Electrical Engineering, and the Zhejiang Key Laboratory of Electrical Technology and System on Renewable Energy, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, and the Zhejiang Key Laboratory of Electrical Technology and System on Renewable Energy, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114038901","display_name":"Jiabei Ge","orcid":null},"institutions":[{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiabei Ge","raw_affiliation_strings":["Electric Power Research Institute, State Grid Zhejiang Electric Power Company Ltd., Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"Electric Power Research Institute, State Grid Zhejiang Electric Power Company Ltd., Hangzhou, China","institution_ids":["https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050294083","display_name":"Yong Yan","orcid":"https://orcid.org/0000-0001-6052-1957"},"institutions":[{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yong Yan","raw_affiliation_strings":["Electric Power Research Institute, State Grid Zhejiang Electric Power Company Ltd., Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"Electric Power Research Institute, State Grid Zhejiang Electric Power Company Ltd., Hangzhou, China","institution_ids":["https://openalex.org/I4210126065"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5014189913","display_name":"Xuanyi Xiao","orcid":"https://orcid.org/0000-0002-8422-8058"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xuanyi Xiao","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5037048914"],"corresponding_institution_ids":["https://openalex.org/I76130692"],"apc_list":null,"apc_paid":null,"fwci":1.3347,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.81633308,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"16","issue":"2","first_page":"1405","last_page":"1421"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.5383440256118774},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49863243103027344},{"id":"https://openalex.org/keywords/modernization-theory","display_name":"Modernization theory","score":0.4666730463504791},{"id":"https://openalex.org/keywords/transmission-network","display_name":"Transmission network","score":0.45753055810928345},{"id":"https://openalex.org/keywords/distribution","display_name":"Distribution (mathematics)","score":0.414085328578949},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.39932796359062195},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3378831744194031},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.29078614711761475},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.28371185064315796},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.20715957880020142}],"concepts":[{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.5383440256118774},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49863243103027344},{"id":"https://openalex.org/C53844881","wikidata":"https://www.wikidata.org/wiki/Q856122","display_name":"Modernization theory","level":2,"score":0.4666730463504791},{"id":"https://openalex.org/C2986640423","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Transmission network","level":3,"score":0.45753055810928345},{"id":"https://openalex.org/C110121322","wikidata":"https://www.wikidata.org/wiki/Q865811","display_name":"Distribution (mathematics)","level":2,"score":0.414085328578949},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.39932796359062195},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3378831744194031},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.29078614711761475},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.28371185064315796},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.20715957880020142},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C50522688","wikidata":"https://www.wikidata.org/wiki/Q189833","display_name":"Economic growth","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2024.3509528","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3509528","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G7023559384","display_name":null,"funder_award_id":"52307146","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G7742822636","display_name":null,"funder_award_id":"52477132","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W2127384497","https://openalex.org/W2565958257","https://openalex.org/W2910148935","https://openalex.org/W2996610266","https://openalex.org/W3128935993","https://openalex.org/W3129037442","https://openalex.org/W3133840471","https://openalex.org/W3148080297","https://openalex.org/W3176704067","https://openalex.org/W4205820335","https://openalex.org/W4213215122","https://openalex.org/W4226360597","https://openalex.org/W4306935917","https://openalex.org/W4312452700","https://openalex.org/W4312805881","https://openalex.org/W4312940192","https://openalex.org/W4365790530","https://openalex.org/W4376457870","https://openalex.org/W4386025620","https://openalex.org/W4387623891","https://openalex.org/W4387917937","https://openalex.org/W4390538735","https://openalex.org/W4390660412"],"related_works":["https://openalex.org/W2385453369","https://openalex.org/W2367160644","https://openalex.org/W2382633101","https://openalex.org/W2349426147","https://openalex.org/W2366351446","https://openalex.org/W2391117647","https://openalex.org/W4387670939","https://openalex.org/W2560361912","https://openalex.org/W2909827418","https://openalex.org/W1977938613"],"abstract_inverted_index":{"The":[0,91],"paper":[1],"proposes":[2],"a":[3,52,78,122],"coordinated":[4,169],"planning":[5,170],"method":[6,80,146,180],"to":[7,33,36,83,121,127,150],"reduce":[8],"redundant":[9],"costs":[10],"for":[11,155],"distribution":[12],"network":[13],"modernization":[14],"with":[15,130],"microgrids":[16],"considering":[17],"the":[18,27,43,68,112,144,164,172,178],"practical":[19,39,151],"configuration":[20],"of":[21,29,93,177],"candidate":[22,40,156],"capacities.":[23],"We":[24],"first":[25],"use":[26],"values":[28],"binary":[30,89,94],"decision":[31,95],"variables":[32,96,100],"represent":[34],"whether":[35],"choose":[37],"corresponding":[38],"capacities,":[41],"whereby":[42],"investment":[44],"choices":[45,154],"are":[46],"definitely":[47],"feasible":[48],"in":[49,61,81,101],"engineering.":[50],"Then,":[51],"bi-level":[53],"stochastic":[54],"model":[55],"that":[56],"incorporates":[57],"combinatorial":[58],"uncertain":[59],"scenarios":[60,85],"spatial-temporal-event":[62],"dimensions":[63],"is":[64,104],"formulated.":[65],"To":[66],"address":[67],"intractable":[69],"large-scale":[70],"mixed":[71,133],"integer":[72,134],"lower-level":[73,102],"models,":[74],"we":[75,116,162],"also":[76],"provide":[77],"clustering":[79],"iterations":[82],"project":[84],"onto":[86],"all":[87],"possible":[88],"decisions.":[90],"number":[92],"and":[97,137,152,171,175],"scenario-related":[98],"state":[99],"models":[103],"thus":[105],"significantly":[106],"reduced":[107],"without":[108],"losing":[109],"accuracy":[110],"at":[111],"same":[113],"time.":[114],"Further,":[115],"extend":[117],"enhanced":[118],"Benders":[119],"decomposition":[120],"hot":[123],"start":[124],"nested":[125],"form":[126],"be":[128],"compatible":[129],"both":[131],"inner-loop":[132],"linear":[135,139],"subproblems":[136],"outer-loop":[138],"security":[140],"assessment":[141],"subproblems.":[142],"Mathematically,":[143],"proposed":[145,179],"can":[147],"rapidly":[148],"converge":[149],"optimal":[153],"capacities":[157],"within":[158],"finite":[159],"iterations.":[160],"Finally,":[161],"validate":[163],"total":[165],"cost":[166],"savings":[167],"from":[168],"optimality,":[173],"rapidity,":[174],"scalability":[176],"on":[181],"integrated":[182],"IEEE":[183],"systems.":[184]},"counts_by_year":[{"year":2025,"cited_by_count":6}],"updated_date":"2025-12-19T19:40:27.379048","created_date":"2025-10-10T00:00:00"}
