{"id":"https://openalex.org/W4404788695","doi":"https://doi.org/10.1109/tsg.2024.3507046","title":"Production Scheduling Identification: An Inverse Optimization Approach for Industrial Load Modeling Using Smart Meter Data","display_name":"Production Scheduling Identification: An Inverse Optimization Approach for Industrial Load Modeling Using Smart Meter Data","publication_year":2024,"publication_date":"2024-11-27","ids":{"openalex":"https://openalex.org/W4404788695","doi":"https://doi.org/10.1109/tsg.2024.3507046"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2024.3507046","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3507046","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5036060529","display_name":"Ruike Lyu","orcid":"https://orcid.org/0000-0003-3749-1117"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ruike Lyu","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-3749-1117","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068695519","display_name":"Hongye Guo","orcid":"https://orcid.org/0000-0002-3741-4288"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongye Guo","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-3741-4288","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009151015","display_name":"Qinghu Tang","orcid":"https://orcid.org/0000-0002-9350-0543"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qinghu Tang","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-9350-0543","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043873168","display_name":"Qixin Chen","orcid":"https://orcid.org/0000-0002-3733-8641"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qixin Chen","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-3733-8641","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100447205","display_name":"Chongqing Kang","orcid":"https://orcid.org/0000-0003-2296-8250"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chongqing Kang","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-2296-8250","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I99065089"],"apc_list":null,"apc_paid":null,"fwci":2.2735,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.89279942,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":"16","issue":"2","first_page":"1207","last_page":"1220"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10551","display_name":"Scheduling and Optimization Algorithms","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10551","display_name":"Scheduling and Optimization Algorithms","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9890999794006348,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-meter","display_name":"Smart meter","score":0.5779262185096741},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.5500461459159851},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5124455094337463},{"id":"https://openalex.org/keywords/identification","display_name":"Identification (biology)","score":0.4581862986087799},{"id":"https://openalex.org/keywords/job-shop-scheduling","display_name":"Job shop scheduling","score":0.4171541631221771},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.3831951320171356},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.3786655068397522},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3292725086212158},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1690773367881775},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16746121644973755},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.12397614121437073}],"concepts":[{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.5779262185096741},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.5500461459159851},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5124455094337463},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.4581862986087799},{"id":"https://openalex.org/C55416958","wikidata":"https://www.wikidata.org/wiki/Q6206757","display_name":"Job shop scheduling","level":3,"score":0.4171541631221771},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.3831951320171356},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.3786655068397522},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3292725086212158},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1690773367881775},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16746121644973755},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.12397614121437073},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C74172769","wikidata":"https://www.wikidata.org/wiki/Q1446839","display_name":"Routing (electronic design automation)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2024.3507046","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3507046","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G1157879939","display_name":null,"funder_award_id":"52321004","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G3493793772","display_name":null,"funder_award_id":"52107102","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":43,"referenced_works":["https://openalex.org/W1543646709","https://openalex.org/W1976217157","https://openalex.org/W2007540906","https://openalex.org/W2010739835","https://openalex.org/W2021191095","https://openalex.org/W2067472954","https://openalex.org/W2070558838","https://openalex.org/W2127618983","https://openalex.org/W2417380646","https://openalex.org/W2516557210","https://openalex.org/W2528626344","https://openalex.org/W2536620281","https://openalex.org/W2551790653","https://openalex.org/W2614529461","https://openalex.org/W2783263312","https://openalex.org/W2786918196","https://openalex.org/W2897044963","https://openalex.org/W2911796152","https://openalex.org/W2912431884","https://openalex.org/W2914005633","https://openalex.org/W2917754011","https://openalex.org/W2962732815","https://openalex.org/W2990458356","https://openalex.org/W3040994746","https://openalex.org/W3081070661","https://openalex.org/W3083021344","https://openalex.org/W3102477513","https://openalex.org/W3109805288","https://openalex.org/W3136109191","https://openalex.org/W3206485780","https://openalex.org/W4200428272","https://openalex.org/W4221010879","https://openalex.org/W4281759667","https://openalex.org/W4285819984","https://openalex.org/W4292983160","https://openalex.org/W4296437229","https://openalex.org/W4310078348","https://openalex.org/W4317496748","https://openalex.org/W4320015737","https://openalex.org/W4378697321","https://openalex.org/W4388197029","https://openalex.org/W4391341629","https://openalex.org/W4392135047"],"related_works":["https://openalex.org/W3018909029","https://openalex.org/W3205631650","https://openalex.org/W2775355700","https://openalex.org/W2246071452","https://openalex.org/W2165970106","https://openalex.org/W1985785385","https://openalex.org/W1124398682","https://openalex.org/W4316660856","https://openalex.org/W2387071565","https://openalex.org/W3090249087"],"abstract_inverted_index":{"To":[0,21],"cost-effectively":[1],"manage":[2],"the":[3,7,10,23,27,39,48,56,64,79,120,155,190],"supply-demand":[4],"balance":[5],"of":[6,12,29,51,82,122,158,174],"power":[8],"system,":[9],"flexibility":[11],"industrial":[13,30,52,71,83,98,106],"users":[14,31,72],"could":[15],"be":[16,61],"harnessed":[17],"through":[18],"demand-side":[19,33],"response.":[20],"minimize":[22],"negative":[24],"impact":[25],"on":[26],"production":[28,53,90,115],"during":[32],"response,":[34],"general-purpose":[35],"models":[36,182],"such":[37],"as":[38],"state-task":[40],"network":[41],"(STN)":[42],"are":[43,67,74,111,129],"widely":[44],"used":[45,112],"to":[46,113,143,187],"model":[47,58,156],"energy-consuming":[49],"constraints":[50],"processes.":[54],"However,":[55],"required":[57,65],"parameters":[59,157],"cannot":[60],"set":[62],"because":[63],"data":[66,110,128],"privately":[68],"owned":[69],"by":[70],"and":[73,138,163,197],"not":[75,194],"directly":[76],"available,":[77],"hindering":[78],"accurate":[80,123,181],"modeling":[81,100,125,191],"loads.":[84],"In":[85,104],"this":[86],"paper,":[87],"we":[88],"propose":[89],"scheduling":[91,116],"identification":[92],"(PSI),":[93],"an":[94,145],"inverse-optimization-based":[95],"approach":[96],"for":[97],"load":[99,124],"under":[101],"incomplete":[102],"information.":[103],"PSI,":[105],"users\u2019":[107],"smart":[108,176],"meter":[109,177],"identify":[114,154],"parameters,":[117],"thus":[118],"addressing":[119],"problem":[121],"when":[126],"private":[127,188],"unavailable.":[130],"We":[131],"implemented":[132],"PSI":[133,152],"with":[134,167,180,184],"a":[135,140,159,164],"modified":[136],"STN":[137],"proposed":[139],"practical":[141],"algorithm":[142],"obtain":[144],"effective":[146],"solution.":[147],"Numerical":[148],"tests":[149],"showed":[150],"that":[151],"can":[153],"steel":[160],"powder":[161],"plant":[162,166],"cement":[165],"acceptable":[168],"accuracy,":[169],"using":[170],"only":[171],"21":[172],"days":[173],"hourly":[175],"data.":[178],"Compared":[179],"established":[183],"direct":[185],"access":[186],"data,":[189],"error":[192],"does":[193],"exceed":[195],"8.5%":[196],"5.2%,":[198],"respectively.":[199]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":4}],"updated_date":"2026-07-07T14:30:12.667765","created_date":"2025-10-10T00:00:00"}
