{"id":"https://openalex.org/W4396598475","doi":"https://doi.org/10.1109/tsg.2024.3396435","title":"Data-Driven Optimal Voltage Performance Index Tracking in Active Distribution Networks","display_name":"Data-Driven Optimal Voltage Performance Index Tracking in Active Distribution Networks","publication_year":2024,"publication_date":"2024-05-02","ids":{"openalex":"https://openalex.org/W4396598475","doi":"https://doi.org/10.1109/tsg.2024.3396435"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2024.3396435","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3396435","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071565207","display_name":"David S. Pacheco-Cherrez","orcid":"https://orcid.org/0000-0003-2697-0542"},"institutions":[{"id":"https://openalex.org/I98461037","display_name":"Tecnol\u00f3gico de Monterrey","ror":"https://ror.org/03ayjn504","country_code":"MX","type":"education","lineage":["https://openalex.org/I98461037"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"David S. Pacheco-Cherrez","raw_affiliation_strings":["School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Mexico"],"raw_orcid":"https://orcid.org/0000-0003-2697-0542","affiliations":[{"raw_affiliation_string":"School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Mexico","institution_ids":["https://openalex.org/I98461037"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063440967","display_name":"Daniel Guill\u00e9n","orcid":"https://orcid.org/0000-0001-9569-9691"},"institutions":[{"id":"https://openalex.org/I98461037","display_name":"Tecnol\u00f3gico de Monterrey","ror":"https://ror.org/03ayjn504","country_code":"MX","type":"education","lineage":["https://openalex.org/I98461037"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"Daniel Guillen","raw_affiliation_strings":["School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Mexico"],"raw_orcid":"https://orcid.org/0000-0001-9569-9691","affiliations":[{"raw_affiliation_string":"School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Mexico","institution_ids":["https://openalex.org/I98461037"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080050535","display_name":"Jonathan C. Mayo\u2010Maldonado","orcid":"https://orcid.org/0000-0003-2513-2395"},"institutions":[{"id":"https://openalex.org/I91136226","display_name":"University of Sheffield","ror":"https://ror.org/05krs5044","country_code":"GB","type":"education","lineage":["https://openalex.org/I91136226"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Jonathan C. Mayo-Maldonado","raw_affiliation_strings":["Department of Electronic and Electrical Engineering, The University of Sheffield, Sheffield, U.K"],"raw_orcid":"https://orcid.org/0000-0003-2513-2395","affiliations":[{"raw_affiliation_string":"Department of Electronic and Electrical Engineering, The University of Sheffield, Sheffield, U.K","institution_ids":["https://openalex.org/I91136226"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5025264533","display_name":"G. Escobar","orcid":"https://orcid.org/0000-0003-0223-2748"},"institutions":[{"id":"https://openalex.org/I98461037","display_name":"Tecnol\u00f3gico de Monterrey","ror":"https://ror.org/03ayjn504","country_code":"MX","type":"education","lineage":["https://openalex.org/I98461037"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"Gerardo Escobar","raw_affiliation_strings":["School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Mexico"],"raw_orcid":"https://orcid.org/0000-0003-0223-2748","affiliations":[{"raw_affiliation_string":"School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey, Mexico","institution_ids":["https://openalex.org/I98461037"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.441,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.80336347,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"15","issue":"5","first_page":"4804","last_page":"4818"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5435975790023804},{"id":"https://openalex.org/keywords/tracking","display_name":"Tracking (education)","score":0.5428019762039185},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5090203285217285},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.47339189052581787},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.438925176858902},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2737525999546051},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2163652777671814},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1508241593837738},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.13044607639312744}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5435975790023804},{"id":"https://openalex.org/C2775936607","wikidata":"https://www.wikidata.org/wiki/Q466845","display_name":"Tracking (education)","level":2,"score":0.5428019762039185},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5090203285217285},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47339189052581787},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.438925176858902},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2737525999546051},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2163652777671814},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1508241593837738},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.13044607639312744},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C19417346","wikidata":"https://www.wikidata.org/wiki/Q7922","display_name":"Pedagogy","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2024.3396435","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3396435","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:eprints.soton.ac.uk:503572","is_oa":false,"landing_page_url":"http://doi.org/10.1109/TSG.2024.3396435>).","pdf_url":null,"source":{"id":"https://openalex.org/S4306401019","display_name":"ePrints Soton (University of Southampton)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I43439940","host_organization_name":"University of Southampton","host_organization_lineage":["https://openalex.org/I43439940"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":null,"raw_type":"PeerReviewed"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7099999785423279,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":63,"referenced_works":["https://openalex.org/W267271646","https://openalex.org/W1502540576","https://openalex.org/W1981612131","https://openalex.org/W1987524177","https://openalex.org/W1999148066","https://openalex.org/W2018139040","https://openalex.org/W2021604425","https://openalex.org/W2052029349","https://openalex.org/W2077564108","https://openalex.org/W2081968592","https://openalex.org/W2095411820","https://openalex.org/W2095638089","https://openalex.org/W2117011443","https://openalex.org/W2119040341","https://openalex.org/W2133661373","https://openalex.org/W2135188150","https://openalex.org/W2139191533","https://openalex.org/W2139861130","https://openalex.org/W2145673230","https://openalex.org/W2166641714","https://openalex.org/W2176175198","https://openalex.org/W2287047720","https://openalex.org/W2318665018","https://openalex.org/W2593427583","https://openalex.org/W2724765071","https://openalex.org/W2725177371","https://openalex.org/W2883076328","https://openalex.org/W2884532022","https://openalex.org/W2909078234","https://openalex.org/W2913831476","https://openalex.org/W2929682102","https://openalex.org/W2954468487","https://openalex.org/W2960239553","https://openalex.org/W2979207987","https://openalex.org/W2982033569","https://openalex.org/W2991859550","https://openalex.org/W2999535065","https://openalex.org/W3011013176","https://openalex.org/W3031264284","https://openalex.org/W3034414265","https://openalex.org/W3043475934","https://openalex.org/W3110616637","https://openalex.org/W3119474806","https://openalex.org/W3128218652","https://openalex.org/W3131436982","https://openalex.org/W3132337045","https://openalex.org/W3152881947","https://openalex.org/W3201161517","https://openalex.org/W3204306846","https://openalex.org/W3209151174","https://openalex.org/W4206269615","https://openalex.org/W4214484041","https://openalex.org/W4214759040","https://openalex.org/W4224271988","https://openalex.org/W4285108065","https://openalex.org/W4285224481","https://openalex.org/W4286781802","https://openalex.org/W4293143428","https://openalex.org/W4312339204","https://openalex.org/W4312439328","https://openalex.org/W4313476434","https://openalex.org/W4366384071","https://openalex.org/W4388392666"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W4391913857","https://openalex.org/W2358668433","https://openalex.org/W4396701345","https://openalex.org/W2376932109","https://openalex.org/W2001405890","https://openalex.org/W4396696052","https://openalex.org/W4402327032"],"abstract_inverted_index":{"This":[0,56,118],"paper":[1,106],"presents":[2],"a":[3,35,43],"data-driven":[4,36,124],"dynamic":[5],"voltage":[6,37,51,64,90],"regulation":[7,91],"approach":[8,77],"that":[9],"coordinates":[10],"medium-voltage":[11],"distributed":[12],"energy":[13,98],"resources":[14],"(DERs)":[15],"and":[16,42,65,102,114],"distribution":[17,24,30,127],"static":[18],"synchronous":[19],"compensators":[20],"(D-STATCOMs)":[21],"in":[22,126],"active":[23],"networks.":[25],"Using":[26],"data":[27],"generated":[28],"by":[29],"phasor":[31],"measurement":[32],"units":[33],"(D-PMUs),":[34],"performance":[38,52,74],"index":[39],"is":[40,46,78],"calculated":[41],"control":[44,57,71,125],"method":[45,58],"proposed":[47],"to":[48,69,111],"ensure":[49],"optimal":[50],"across":[53],"network":[54],"nodes.":[55],"requires":[59],"minimal":[60],"data,":[61],"using":[62,133],"only":[63],"reactive":[66],"power":[67],"measurements":[68],"generate":[70],"signals.":[72],"The":[73,105],"of":[75,123],"this":[76],"validated":[79],"through":[80],"simulation":[81],"tests":[82],"on":[83],"IEEE-33":[84],"node":[85],"test":[86],"feeders,":[87],"demonstrating":[88],"efficient":[89],"under":[92],"challenging":[93],"conditions":[94],"such":[95],"as":[96],"solar":[97],"integration,":[99],"grid":[100,139],"faults,":[101],"topology":[103],"changes.":[104],"also":[107],"explores":[108],"additional":[109],"contributions":[110],"system":[112],"identification":[113],"digital":[115],"twin":[116],"techniques.":[117],"work":[119],"highlights":[120],"the":[121],"potential":[122],"networks":[128],"for":[129,137],"effective":[130],"Volt/Var":[131],"control,":[132],"modern":[134],"smart-grid":[135],"technologies":[136],"improved":[138],"management.":[140]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":2}],"updated_date":"2026-08-12T21:12:35.861297","created_date":"2025-10-10T00:00:00"}
