{"id":"https://openalex.org/W4396525072","doi":"https://doi.org/10.1109/tsg.2024.3395448","title":"Distributed Data-Driven Frequency Control in Networked Microgrids via Voltage Regulation","display_name":"Distributed Data-Driven Frequency Control in Networked Microgrids via Voltage Regulation","publication_year":2024,"publication_date":"2024-04-30","ids":{"openalex":"https://openalex.org/W4396525072","doi":"https://doi.org/10.1109/tsg.2024.3395448"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2024.3395448","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3395448","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077914174","display_name":"Zhiyuan Tang","orcid":"https://orcid.org/0000-0002-2023-757X"},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zhiyuan Tang","raw_affiliation_strings":["School of Electrical Engineering, Sichuan University, Chengdu, China"],"raw_orcid":"https://orcid.org/0000-0002-2023-757X","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Sichuan University, Chengdu, China","institution_ids":["https://openalex.org/I24185976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073676336","display_name":"Youbo Liu","orcid":"https://orcid.org/0000-0002-5465-5243"},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Youbo Liu","raw_affiliation_strings":["School of Electrical Engineering, Sichuan University, Chengdu, China"],"raw_orcid":"https://orcid.org/0000-0002-5465-5243","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Sichuan University, Chengdu, China","institution_ids":["https://openalex.org/I24185976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064429179","display_name":"Tingjian Liu","orcid":"https://orcid.org/0000-0003-4790-646X"},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tingjian Liu","raw_affiliation_strings":["School of Electrical Engineering, Sichuan University, Chengdu, China"],"raw_orcid":"https://orcid.org/0000-0003-4790-646X","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Sichuan University, Chengdu, China","institution_ids":["https://openalex.org/I24185976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054795087","display_name":"Gao Qiu","orcid":"https://orcid.org/0000-0001-5257-7280"},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Gao Qiu","raw_affiliation_strings":["School of Electrical Engineering, Sichuan University, Chengdu, China"],"raw_orcid":"https://orcid.org/0000-0001-5257-7280","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Sichuan University, Chengdu, China","institution_ids":["https://openalex.org/I24185976"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108114624","display_name":"Junyong Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Junyong Liu","raw_affiliation_strings":["School of Electrical Engineering, Sichuan University, Chengdu, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Sichuan University, Chengdu, China","institution_ids":["https://openalex.org/I24185976"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5077914174"],"corresponding_institution_ids":["https://openalex.org/I24185976"],"apc_list":null,"apc_paid":null,"fwci":2.4666,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.88761283,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"15","issue":"5","first_page":"4393","last_page":"4406"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8754953742027283},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6432395577430725},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.6243297457695007},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.6197506785392761},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5947815775871277},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.5849006175994873},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.5637657046318054},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.559670090675354},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5156282782554626},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.5080931186676025},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4622255563735962},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.45045194029808044},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.42707371711730957},{"id":"https://openalex.org/keywords/automatic-generation-control","display_name":"Automatic Generation Control","score":0.4132692515850067},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.41142308712005615},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.41063418984413147},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3568924069404602},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2969273328781128},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.23790067434310913},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.07387825846672058},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.07372641563415527}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8754953742027283},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6432395577430725},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.6243297457695007},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6197506785392761},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5947815775871277},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.5849006175994873},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.5637657046318054},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.559670090675354},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5156282782554626},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5080931186676025},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4622255563735962},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.45045194029808044},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.42707371711730957},{"id":"https://openalex.org/C2778763806","wikidata":"https://www.wikidata.org/wiki/Q4826572","display_name":"Automatic Generation Control","level":4,"score":0.4132692515850067},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.41142308712005615},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.41063418984413147},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3568924069404602},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2969273328781128},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.23790067434310913},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.07387825846672058},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.07372641563415527},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2024.3395448","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2024.3395448","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G3495725977","display_name":null,"funder_award_id":"52207127","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G6645168560","display_name":null,"funder_award_id":"YJ2021163","funder_id":"https://openalex.org/F4320335787","funder_display_name":"Fundamental Research Funds for the Central Universities"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320335787","display_name":"Fundamental Research Funds for the Central Universities","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":37,"referenced_works":["https://openalex.org/W1763243278","https://openalex.org/W1969576074","https://openalex.org/W1993608030","https://openalex.org/W2001965107","https://openalex.org/W2063710378","https://openalex.org/W2097982640","https://openalex.org/W2173265528","https://openalex.org/W2517231046","https://openalex.org/W2526981415","https://openalex.org/W2582094143","https://openalex.org/W2610794370","https://openalex.org/W2775279201","https://openalex.org/W2799638352","https://openalex.org/W2900859370","https://openalex.org/W2919580381","https://openalex.org/W2928951073","https://openalex.org/W2980926838","https://openalex.org/W2991458339","https://openalex.org/W3009880228","https://openalex.org/W3012486745","https://openalex.org/W3031264284","https://openalex.org/W3038778452","https://openalex.org/W3070953475","https://openalex.org/W3081478801","https://openalex.org/W3090464646","https://openalex.org/W3092181839","https://openalex.org/W3094580668","https://openalex.org/W3111538979","https://openalex.org/W3159770993","https://openalex.org/W3172758991","https://openalex.org/W3188175424","https://openalex.org/W3188405497","https://openalex.org/W3202817191","https://openalex.org/W4293370862","https://openalex.org/W4312805881","https://openalex.org/W4313434117","https://openalex.org/W4388240279"],"related_works":["https://openalex.org/W2355150740","https://openalex.org/W1570369983","https://openalex.org/W2051053503","https://openalex.org/W2906602677","https://openalex.org/W3112588909","https://openalex.org/W1993958856","https://openalex.org/W2076021085","https://openalex.org/W2061539888","https://openalex.org/W2104973077","https://openalex.org/W3006223230"],"abstract_inverted_index":{"In":[0,18],"this":[1],"paper,":[2],"a":[3,92,135],"distributed":[4,93],"data-driven":[5],"frequency":[6,23],"control":[7,70,87],"scheme":[8,88],"is":[9,24,56,72,89,125],"proposed":[10,20,141,157],"for":[11,164],"the":[12,19,22,29,38,48,61,75,85,113,121,129,140,152,156,162,172],"off-grid":[13],"networked":[14],"microgrid":[15],"system":[16,119,123,168],"(NMG).":[17],"scheme,":[21],"regulated":[25],"by":[26,34,43,59,95,104],"coordinately":[27],"adjusting":[28,60],"active":[30,39,49],"power":[31,40,50],"generation":[32],"provided":[33,42],"controllable":[35,175],"generators":[36],"and":[37,83,177],"demand":[41],"voltage":[44,53,66],"sensitive":[45,54],"loads,":[46],"where":[47],"consumption":[51],"of":[52,155,174],"loads":[55],"specially":[57],"modified":[58],"load":[62],"operating":[63],"voltages":[64],"via":[65,128],"regulation.":[67],"The":[68],"whole":[69],"problem":[71],"solved":[73],"with":[74],"feedback-based":[76],"gradient":[77,99],"method.":[78],"To":[79,110],"achieve":[80],"better":[81],"scalability":[82],"privacy,":[84],"overall":[86],"implemented":[90],"in":[91,134],"manner":[94],"employing":[96],"an":[97,165],"approximated":[98],"that":[100],"can":[101],"be":[102],"calculated":[103],"limited":[105],"communication":[106,182],"between":[107],"neighboring":[108],"MGs.":[109],"further":[111],"enable":[112],"controller":[114,142],"to":[115,117],"adapt":[116],"real-time":[118],"conditions,":[120],"required":[122],"model":[124],"updated":[126],"online":[127],"partial":[130],"least":[131],"square":[132],"method":[133],"recursive":[136],"manner,":[137],"which":[138],"renders":[139],"model-free.":[143],"Numerical":[144],"simulations":[145],"involving":[146],"detailed":[147],"nonlinear":[148],"NMG":[149],"models":[150],"illustrate":[151],"key":[153],"benefits":[154],"method,":[158],"including":[159],"(i)":[160],"eliminating":[161],"need":[163,173],"accurate":[166],"offline":[167],"model,":[169],"(ii)":[170],"reducing":[171],"generation,":[176],"(iii)":[178],"being":[179],"robust":[180],"against":[181],"delays.":[183]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":5}],"updated_date":"2026-05-07T13:39:58.223016","created_date":"2025-10-10T00:00:00"}
