{"id":"https://openalex.org/W4387144372","doi":"https://doi.org/10.1109/tsg.2023.3278094","title":"Stabilization of DC Microgrids Under Cyber Attacks-Optimal Design and Sensitivity Analysis","display_name":"Stabilization of DC Microgrids Under Cyber Attacks-Optimal Design and Sensitivity Analysis","publication_year":2023,"publication_date":"2023-05-19","ids":{"openalex":"https://openalex.org/W4387144372","doi":"https://doi.org/10.1109/tsg.2023.3278094"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2023.3278094","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2023.3278094","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://vbn.aau.dk/ws/files/529076890/FINAL_VERSION.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013403515","display_name":"Minrui Leng","orcid":"https://orcid.org/0000-0002-0616-3340"},"institutions":[{"id":"https://openalex.org/I24185976","display_name":"Sichuan University","ror":"https://ror.org/011ashp19","country_code":"CN","type":"education","lineage":["https://openalex.org/I24185976"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Minrui Leng","raw_affiliation_strings":["College of Electrical Engineering, Sichuan University, Chengdu, China"],"raw_orcid":"https://orcid.org/0000-0002-0616-3340","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Sichuan University, Chengdu, China","institution_ids":["https://openalex.org/I24185976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066635275","display_name":"Subham Sahoo","orcid":"https://orcid.org/0000-0002-7916-028X"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Subham Sahoo","raw_affiliation_strings":["Department of Energy, Aalborg University, Aalborg, Denmark"],"raw_orcid":"https://orcid.org/0000-0002-7916-028X","affiliations":[{"raw_affiliation_string":"Department of Energy, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5039395705","display_name":"Frede Blaabjerg","orcid":"https://orcid.org/0000-0001-8311-7412"},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Frede Blaabjerg","raw_affiliation_strings":["Department of Energy, Aalborg University, Aalborg, Denmark"],"raw_orcid":"https://orcid.org/0000-0001-8311-7412","affiliations":[{"raw_affiliation_string":"Department of Energy, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.5058,"has_fulltext":true,"cited_by_count":13,"citation_normalized_percentile":{"value":0.80966577,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":98},"biblio":{"volume":"15","issue":"1","first_page":"113","last_page":"123"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9550999999046326,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.8321806192398071},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.6971596479415894},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.665447473526001},{"id":"https://openalex.org/keywords/cyber-physical-system","display_name":"Cyber-physical system","score":0.6605511903762817},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4826681911945343},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4754723608493805},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4704545736312866},{"id":"https://openalex.org/keywords/cyber-attack","display_name":"Cyber-attack","score":0.4432508945465088},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.43026962876319885},{"id":"https://openalex.org/keywords/function","display_name":"Function (biology)","score":0.4275633692741394},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.4141938388347626},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.37368810176849365},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3344796895980835},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.21000272035598755},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.15777146816253662},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.12906396389007568}],"concepts":[{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.8321806192398071},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.6971596479415894},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.665447473526001},{"id":"https://openalex.org/C179768478","wikidata":"https://www.wikidata.org/wiki/Q1120057","display_name":"Cyber-physical system","level":2,"score":0.6605511903762817},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4826681911945343},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4754723608493805},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4704545736312866},{"id":"https://openalex.org/C201307755","wikidata":"https://www.wikidata.org/wiki/Q4071928","display_name":"Cyber-attack","level":2,"score":0.4432508945465088},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.43026962876319885},{"id":"https://openalex.org/C14036430","wikidata":"https://www.wikidata.org/wiki/Q3736076","display_name":"Function (biology)","level":2,"score":0.4275633692741394},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.4141938388347626},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.37368810176849365},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3344796895980835},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.21000272035598755},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.15777146816253662},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.12906396389007568},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C78458016","wikidata":"https://www.wikidata.org/wiki/Q840400","display_name":"Evolutionary biology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tsg.2023.3278094","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2023.3278094","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/c00f96e7-3f8a-4e16-a1fc-26940fbff9d2","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/c00f96e7-3f8a-4e16-a1fc-26940fbff9d2","pdf_url":"https://vbn.aau.dk/ws/files/529076890/FINAL_VERSION.pdf","source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Leng, M, Sahoo, S & Blaabjerg, F 2024, 'Stabilization of DC Microgrids Under Cyber Attacks : Optimal Design and Sensitivity Analysis', I E E E Transactions on Smart Grid, vol. 15, no. 1, pp. 113 - 123. https://doi.org/10.1109/TSG.2023.3278094","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:pure.atira.dk:publications/c00f96e7-3f8a-4e16-a1fc-26940fbff9d2","is_oa":true,"landing_page_url":"http://www.scopus.com/inward/record.url?scp=85160263688&partnerID=8YFLogxK","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Leng , M , Sahoo , S &amp; Blaabjerg , F 2024 , ' Stabilization of DC Microgrids Under Stealth Cyber Attacks - Optimal Design and Sensitivity Analysis ' , I E E E Transactions on Smart Grid , vol. 15 , no. 1 , 3278094 , pp. 113-123 . https://doi.org/10.1109/TSG.2023.3278094","raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:publications/c00f96e7-3f8a-4e16-a1fc-26940fbff9d2","is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/c00f96e7-3f8a-4e16-a1fc-26940fbff9d2","pdf_url":"https://vbn.aau.dk/ws/files/529076890/FINAL_VERSION.pdf","source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Leng, M, Sahoo, S & Blaabjerg, F 2024, 'Stabilization of DC Microgrids Under Cyber Attacks : Optimal Design and Sensitivity Analysis', I E E E Transactions on Smart Grid, vol. 15, no. 1, pp. 113 - 123. https://doi.org/10.1109/TSG.2023.3278094","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"score":0.8700000047683716,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G4691350150","display_name":null,"funder_award_id":"117766","funder_id":"https://openalex.org/F4320323669","funder_display_name":"Nordic Energy Research"}],"funders":[{"id":"https://openalex.org/F4320310490","display_name":"Villum Fonden","ror":"https://ror.org/007ww2d15"},{"id":"https://openalex.org/F4320323669","display_name":"Nordic Energy Research","ror":"https://ror.org/035jwz470"}],"has_content":{"pdf":true,"grobid_xml":false},"content_urls":{"pdf":"https://content.openalex.org/works/W4387144372.pdf"},"referenced_works_count":19,"referenced_works":["https://openalex.org/W2003530067","https://openalex.org/W2095411820","https://openalex.org/W2166935440","https://openalex.org/W2742921434","https://openalex.org/W2791047555","https://openalex.org/W2900117237","https://openalex.org/W2904557769","https://openalex.org/W2971224052","https://openalex.org/W3014429688","https://openalex.org/W3022799595","https://openalex.org/W3025906261","https://openalex.org/W3037607201","https://openalex.org/W3183633007","https://openalex.org/W3201571347","https://openalex.org/W3203001013","https://openalex.org/W3217453330","https://openalex.org/W4285241635","https://openalex.org/W4292998654","https://openalex.org/W4296049535"],"related_works":["https://openalex.org/W2381722214","https://openalex.org/W2358245908","https://openalex.org/W2292822667","https://openalex.org/W2974890647","https://openalex.org/W2070261081","https://openalex.org/W4385452087","https://openalex.org/W4304097726","https://openalex.org/W4304097727","https://openalex.org/W2177488045","https://openalex.org/W3123953333"],"abstract_inverted_index":{"Due":[0],"to":[1,20,80,90,113,159],"increased":[2],"efforts":[3],"on":[4,55,74,97,119,131],"digitizing":[5],"the":[6,21,31,56,64,82,86,104,142,145,160],"modern":[7],"power":[8],"electronic":[9],"systems":[10],"and":[11,16,38,60,94,128,164],"microgrids,":[12],"their":[13],"operational":[14],"reliability":[15],"stability":[17,33,83,98,163],"are":[18,72,116,125],"prone":[19],"risk":[22],"of":[23,46,63,106,108,144,167],"cyber":[24,49,114],"attacks.":[25,50],"In":[26,102],"this":[27],"paper,":[28],"we":[29,52],"inspect":[30],"overlooked":[32],"issues":[34],"caused":[35],"by":[36],"cyber-attacks,":[37],"present":[39],"an":[40],"overall":[41,161],"design":[42,58,121,147],"insight":[43],"for":[44,66],"stabilization":[45,95],"microgrids":[47,67,132],"under":[48,68],"Firstly,":[51],"shed":[53],"light":[54],"optimal":[57,123],"policy":[59],"sensitivity":[61,87,107,166],"aspects":[62],"solution":[65],"cyber-attacks.":[69],"These":[70],"results":[71],"based":[73],"a":[75,137,151],"describing":[76],"function-based":[77],"modeling":[78],"method":[79],"map":[81],"region.":[84],"Secondly,":[85],"impact":[88],"due":[89],"system":[91],"parameter":[92,109,165],"variations":[93,110],"gains":[96],"is":[99],"theoretically":[100,126],"investigated.":[101],"addition,":[103],"range":[105],"with":[111],"respect":[112],"attacks":[115],"calculated.":[117],"Based":[118],"different":[120,134],"requirements,":[122],"values":[124],"obtained":[127],"then":[129],"tested":[130],"having":[133],"parameters":[135],"in":[136],"simulation":[138],"environment,":[139],"which":[140,154],"justifies":[141],"ruggedness":[143],"proposed":[146],"approach.":[148],"We":[149],"provide":[150],"generalized":[152],"philosophy,":[153],"can":[155],"be":[156],"easily":[157],"extended":[158],"design,":[162],"cyber-physical":[168],"energy":[169],"systems.":[170]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":2}],"updated_date":"2026-07-23T08:03:31.855105","created_date":"2025-10-10T00:00:00"}
