{"id":"https://openalex.org/W4296872257","doi":"https://doi.org/10.1109/tsg.2022.3208884","title":"Cooperative Repair Scheduling and Service Restoration for Distribution Systems With Soft Open Points","display_name":"Cooperative Repair Scheduling and Service Restoration for Distribution Systems With Soft Open Points","publication_year":2022,"publication_date":"2022-09-23","ids":{"openalex":"https://openalex.org/W4296872257","doi":"https://doi.org/10.1109/tsg.2022.3208884"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2022.3208884","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2022.3208884","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100411292","display_name":"Xiaodong Yang","orcid":"https://orcid.org/0000-0002-3103-4452"},"institutions":[{"id":"https://openalex.org/I16365422","display_name":"Hefei University of Technology","ror":"https://ror.org/02czkny70","country_code":"CN","type":"education","lineage":["https://openalex.org/I16365422"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Xiaodong Yang","raw_affiliation_strings":["Anhui Province Key Laboratory of Renewable Energy Utilization and Energy Saving, Hefei University of Technology, Hefei, China"],"raw_orcid":"https://orcid.org/0000-0002-3103-4452","affiliations":[{"raw_affiliation_string":"Anhui Province Key Laboratory of Renewable Energy Utilization and Energy Saving, Hefei University of Technology, Hefei, China","institution_ids":["https://openalex.org/I16365422"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073068939","display_name":"Chongbo Xu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chongbo Xu","raw_affiliation_strings":["YiQiYin (Hangzhou) Technology Company Ltd., Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"YiQiYin (Hangzhou) Technology Company Ltd., Hangzhou, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100641767","display_name":"Jinyu Wen","orcid":"https://orcid.org/0000-0002-0288-727X"},"institutions":[{"id":"https://openalex.org/I47720641","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53","country_code":"CN","type":"education","lineage":["https://openalex.org/I47720641"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinyu Wen","raw_affiliation_strings":["State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China"],"raw_orcid":"https://orcid.org/0000-0002-0288-727X","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China","institution_ids":["https://openalex.org/I47720641"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083057124","display_name":"Youbing Zhang","orcid":"https://orcid.org/0000-0003-4868-5283"},"institutions":[{"id":"https://openalex.org/I55712492","display_name":"Zhejiang University of Technology","ror":"https://ror.org/02djqfd08","country_code":"CN","type":"education","lineage":["https://openalex.org/I55712492"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Youbing Zhang","raw_affiliation_strings":["College of Information Engineering, Zhejiang University of Technology, Hangzhou, China"],"raw_orcid":"https://orcid.org/0000-0003-4868-5283","affiliations":[{"raw_affiliation_string":"College of Information Engineering, Zhejiang University of Technology, Hangzhou, China","institution_ids":["https://openalex.org/I55712492"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010334964","display_name":"Qiuwei Wu","orcid":"https://orcid.org/0000-0001-7935-2567"},"institutions":[{"id":"https://openalex.org/I4210114105","display_name":"Tsinghua\u2013Berkeley Shenzhen Institute","ror":"https://ror.org/02hhwwz98","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210114105","https://openalex.org/I95457486","https://openalex.org/I99065089"]},{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qiuwei Wu","raw_affiliation_strings":["Tsinghua-Berkeley Shenzhen Institute, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China"],"raw_orcid":"https://orcid.org/0000-0001-7935-2567","affiliations":[{"raw_affiliation_string":"Tsinghua-Berkeley Shenzhen Institute, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China","institution_ids":["https://openalex.org/I4210114105","https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041714347","display_name":"Wenping Zuo","orcid":"https://orcid.org/0000-0002-4562-4680"},"institutions":[{"id":"https://openalex.org/I47720641","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53","country_code":"CN","type":"education","lineage":["https://openalex.org/I47720641"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wenping Zuo","raw_affiliation_strings":["State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China"],"raw_orcid":"https://orcid.org/0000-0002-4562-4680","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China","institution_ids":["https://openalex.org/I47720641"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103912345","display_name":"Shijie Cheng","orcid":null},"institutions":[{"id":"https://openalex.org/I47720641","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53","country_code":"CN","type":"education","lineage":["https://openalex.org/I47720641"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shijie Cheng","raw_affiliation_strings":["State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China","institution_ids":["https://openalex.org/I47720641"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5100411292"],"corresponding_institution_ids":["https://openalex.org/I16365422"],"apc_list":null,"apc_paid":null,"fwci":4.8027,"has_fulltext":false,"cited_by_count":56,"citation_normalized_percentile":{"value":0.95889204,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":99,"max":100},"biblio":{"volume":"14","issue":"3","first_page":"1827","last_page":"1842"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9944000244140625,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.5755817294120789},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5668365955352783},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5006942749023438},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4898979067802429},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4626617729663849},{"id":"https://openalex.org/keywords/fault-management","display_name":"Fault management","score":0.4612518548965454},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.449964702129364},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.44445574283599854},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4387006461620331},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.4344737231731415},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.43250271677970886},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.42894458770751953},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2710948586463928},{"id":"https://openalex.org/keywords/node","display_name":"Node (physics)","score":0.2555444538593292},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.21157553791999817},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12654170393943787}],"concepts":[{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.5755817294120789},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5668365955352783},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5006942749023438},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4898979067802429},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4626617729663849},{"id":"https://openalex.org/C108074857","wikidata":"https://www.wikidata.org/wiki/Q3067360","display_name":"Fault management","level":3,"score":0.4612518548965454},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.449964702129364},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.44445574283599854},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4387006461620331},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4344737231731415},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.43250271677970886},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.42894458770751953},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2710948586463928},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.2555444538593292},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.21157553791999817},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12654170393943787},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2022.3208884","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2022.3208884","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2111938495","display_name":null,"funder_award_id":"U19A20106","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G4981770904","display_name":null,"funder_award_id":"U22B20116","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G7714512229","display_name":null,"funder_award_id":"52007074","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":44,"referenced_works":["https://openalex.org/W2089635373","https://openalex.org/W2100197017","https://openalex.org/W2203064089","https://openalex.org/W2562736183","https://openalex.org/W2570440071","https://openalex.org/W2571088323","https://openalex.org/W2726498110","https://openalex.org/W2740756888","https://openalex.org/W2799787357","https://openalex.org/W2809282503","https://openalex.org/W2811484260","https://openalex.org/W2888193559","https://openalex.org/W2894506939","https://openalex.org/W2906021720","https://openalex.org/W2915153928","https://openalex.org/W2945690175","https://openalex.org/W2954463157","https://openalex.org/W2957344231","https://openalex.org/W2963149075","https://openalex.org/W2984372691","https://openalex.org/W3000007750","https://openalex.org/W3006718767","https://openalex.org/W3008171139","https://openalex.org/W3024682676","https://openalex.org/W3025886862","https://openalex.org/W3035268023","https://openalex.org/W3045689935","https://openalex.org/W3048739684","https://openalex.org/W3098966795","https://openalex.org/W3100416601","https://openalex.org/W3111476067","https://openalex.org/W3117935061","https://openalex.org/W3119188633","https://openalex.org/W3146714375","https://openalex.org/W3175093674","https://openalex.org/W3190160068","https://openalex.org/W3206871075","https://openalex.org/W4206123276","https://openalex.org/W4211175495","https://openalex.org/W4221133128","https://openalex.org/W4226096581","https://openalex.org/W4293195421","https://openalex.org/W6810730305","https://openalex.org/W6841829430"],"related_works":["https://openalex.org/W2086397253","https://openalex.org/W2133122801","https://openalex.org/W600422426","https://openalex.org/W2007156430","https://openalex.org/W3081478936","https://openalex.org/W2751256511","https://openalex.org/W2785612136","https://openalex.org/W2099529706","https://openalex.org/W1597785538","https://openalex.org/W1988224651"],"abstract_inverted_index":{"Fault":[0],"management":[1],"is":[2,96,131,161],"one":[3],"of":[4,8,86,179,202],"the":[5,31,43,47,50,69,83,92,100,122,177,200,203],"crucial":[6],"functions":[7],"Smart":[9],"Grid":[10],"to":[11,15,41,64,81,115,142],"bring":[12],"system":[13,66,76,192,198],"back":[14],"normal":[16],"operation":[17],"from":[18],"fault":[19,60,159],"events.":[20],"In":[21,46],"this":[22,103],"paper,":[23],"we":[24,105],"propose":[25],"a":[26,107,128,187,194],"multi-period":[27],"cooperative":[28],"solution":[29,114],"for":[30,121,154],"jointly":[32],"repair":[33,70,137,145,170,180],"and":[34,59,71,139,146,171,174,193],"restoration":[35,72,94,141],"problem":[36],"in":[37,99,124,182],"distribution":[38,197],"systems":[39],"(DSs)":[40],"minimize":[42],"de-energized":[44],"loads.":[45],"proposed":[48,204],"scheme,":[49],"novel":[51],"fully-controlled":[52],"power-electronic":[53],"device":[54],"SOP":[55,135,151],"(soft":[56],"open":[57],"point)":[58],"isolation":[61,160],"are":[62],"included":[63],"accelerate":[65],"restoration.":[67],"As":[68],"process":[73,95],"goes":[74],"forward,":[75],"topology":[77],"changes":[78],"frequently.":[79],"How":[80],"determine":[82],"control":[84,118,152],"mode":[85,119,153],"SOPs":[87,123],"considering":[88],"their":[89],"characteristics":[90],"during":[91],"entire":[93],"rarely":[97],"studied":[98],"literature.":[101],"To":[102],"end,":[104],"present":[106],"new":[108],"virtual":[109],"power":[110],"flow":[111],"based":[112],"automatic":[113],"adaptively":[116],"perform":[117],"switching":[120],"faulted":[125],"DS.":[126],"Furthermore,":[127],"co-optimization":[129],"model":[130],"formulated":[132],"that":[133],"coordinates":[134],"control,":[136],"scheduling":[138],"DS":[140,155],"obtain":[143],"optimal":[144],"switch":[147,172],"action":[148],"sequences":[149],"matching":[150],"resilience":[156],"enhancement.":[157],"The":[158],"also":[162],"conducted,":[163],"since":[164],"it":[165],"has":[166],"great":[167],"impacts":[168],"on":[169,186],"operations":[173],"can":[175],"guarantee":[176],"safety":[178],"crews":[181],"practice.":[183],"Numerical":[184],"simulations":[185],"modified":[188],"IEEE":[189],"123-node":[190],"test":[191],"large-scale":[195],"actual":[196],"verify":[199],"effectiveness":[201],"model.":[205]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":19},{"year":2024,"cited_by_count":23},{"year":2023,"cited_by_count":10}],"updated_date":"2026-05-07T13:39:58.223016","created_date":"2025-10-10T00:00:00"}
