{"id":"https://openalex.org/W4298282269","doi":"https://doi.org/10.1109/tsg.2022.3197626","title":"Resilience Enhancement of Integrated Electricity-Gas-Heat Urban Energy System With Data Centres Considering Waste Heat Reuse","display_name":"Resilience Enhancement of Integrated Electricity-Gas-Heat Urban Energy System With Data Centres Considering Waste Heat Reuse","publication_year":2022,"publication_date":"2022-08-09","ids":{"openalex":"https://openalex.org/W4298282269","doi":"https://doi.org/10.1109/tsg.2022.3197626"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2022.3197626","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2022.3197626","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101502386","display_name":"Ran Tao","orcid":"https://orcid.org/0000-0003-4564-4312"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ran Tao","raw_affiliation_strings":["School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-4564-4312","affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015759201","display_name":"Dongmei Zhao","orcid":"https://orcid.org/0000-0001-8717-7906"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dongmei Zhao","raw_affiliation_strings":["School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101908953","display_name":"Chenyu Xu","orcid":"https://orcid.org/0000-0003-3957-1137"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chenyu Xu","raw_affiliation_strings":["School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-3957-1137","affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042417097","display_name":"Haoxiang Wang","orcid":"https://orcid.org/0000-0002-0361-6527"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haoxiang Wang","raw_affiliation_strings":["School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000758800","display_name":"Xuan Xia","orcid":"https://orcid.org/0000-0002-0118-7482"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xuan Xia","raw_affiliation_strings":["Substation Transportation Inspection Center, State Grid Shaoxing Power Supply Company, Shaoxing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Substation Transportation Inspection Center, State Grid Shaoxing Power Supply Company, Shaoxing, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.4456,"has_fulltext":false,"cited_by_count":42,"citation_normalized_percentile":{"value":0.93358177,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"14","issue":"1","first_page":"183","last_page":"198"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9896000027656555,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11807","display_name":"Infrastructure Resilience and Vulnerability Analysis","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/waste-heat","display_name":"Waste heat","score":0.6826908588409424},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.600997269153595},{"id":"https://openalex.org/keywords/reuse","display_name":"Reuse","score":0.5935798287391663},{"id":"https://openalex.org/keywords/resilience","display_name":"Resilience (materials science)","score":0.4709739685058594},{"id":"https://openalex.org/keywords/waste-heat-recovery-unit","display_name":"Waste heat recovery unit","score":0.43370482325553894},{"id":"https://openalex.org/keywords/interdependence","display_name":"Interdependence","score":0.4236880838871002},{"id":"https://openalex.org/keywords/workload","display_name":"Workload","score":0.4209703207015991},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.37678638100624084},{"id":"https://openalex.org/keywords/process-engineering","display_name":"Process engineering","score":0.3735243082046509},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.36933374404907227},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3060229420661926},{"id":"https://openalex.org/keywords/waste-management","display_name":"Waste management","score":0.1976509690284729},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.16187632083892822},{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.10678297281265259},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10250884294509888},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.10072958469390869}],"concepts":[{"id":"https://openalex.org/C184235594","wikidata":"https://www.wikidata.org/wiki/Q288706","display_name":"Waste heat","level":3,"score":0.6826908588409424},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.600997269153595},{"id":"https://openalex.org/C206588197","wikidata":"https://www.wikidata.org/wiki/Q846574","display_name":"Reuse","level":2,"score":0.5935798287391663},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.4709739685058594},{"id":"https://openalex.org/C105994980","wikidata":"https://www.wikidata.org/wiki/Q15081379","display_name":"Waste heat recovery unit","level":3,"score":0.43370482325553894},{"id":"https://openalex.org/C185874996","wikidata":"https://www.wikidata.org/wiki/Q269699","display_name":"Interdependence","level":2,"score":0.4236880838871002},{"id":"https://openalex.org/C2778476105","wikidata":"https://www.wikidata.org/wiki/Q628539","display_name":"Workload","level":2,"score":0.4209703207015991},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37678638100624084},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.3735243082046509},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.36933374404907227},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3060229420661926},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.1976509690284729},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.16187632083892822},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.10678297281265259},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10250884294509888},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.10072958469390869},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2022.3197626","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2022.3197626","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Sustainable cities and communities","score":0.46000000834465027,"id":"https://metadata.un.org/sdg/11"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":42,"referenced_works":["https://openalex.org/W1918816242","https://openalex.org/W1988553127","https://openalex.org/W1988622494","https://openalex.org/W1992589176","https://openalex.org/W2086320881","https://openalex.org/W2097964682","https://openalex.org/W2243705582","https://openalex.org/W2284351912","https://openalex.org/W2499358387","https://openalex.org/W2602240020","https://openalex.org/W2604739525","https://openalex.org/W2612033239","https://openalex.org/W2613791018","https://openalex.org/W2728050068","https://openalex.org/W2754327173","https://openalex.org/W2767686712","https://openalex.org/W2789321149","https://openalex.org/W2795032369","https://openalex.org/W2808076419","https://openalex.org/W2809282503","https://openalex.org/W2810216972","https://openalex.org/W2883602331","https://openalex.org/W2891533863","https://openalex.org/W2900414872","https://openalex.org/W2906832930","https://openalex.org/W2914416705","https://openalex.org/W2935980416","https://openalex.org/W2953969189","https://openalex.org/W2960876015","https://openalex.org/W2997772627","https://openalex.org/W3023090257","https://openalex.org/W3042185101","https://openalex.org/W3102098736","https://openalex.org/W3102893070","https://openalex.org/W3105558219","https://openalex.org/W3110719419","https://openalex.org/W3114056273","https://openalex.org/W3133984803","https://openalex.org/W3152907029","https://openalex.org/W3197642522","https://openalex.org/W3209212772","https://openalex.org/W4237815892"],"related_works":["https://openalex.org/W2387302502","https://openalex.org/W2946527108","https://openalex.org/W2484086772","https://openalex.org/W3200016639","https://openalex.org/W4312842629","https://openalex.org/W4388915671","https://openalex.org/W2801934545","https://openalex.org/W2212983040","https://openalex.org/W2384810028","https://openalex.org/W2002155226"],"abstract_inverted_index":{"In":[0,36],"this":[1],"paper,":[2],"a":[3],"novel":[4],"co-optimization":[5,120],"model":[6,63],"is":[7],"proposed":[8,62,119],"for":[9],"integrated":[10],"electricity-gas-heat":[11],"urban":[12,57,129],"energy":[13,69,130,147],"systems":[14,70,131,148],"to":[15,38,53,133,155],"improve":[16],"resilience":[17,127],"during":[18],"extreme":[19,156],"events.":[20,157],"This":[21],"paper":[22],"modelled":[23],"and":[24,32,71,83,98,108,143,153],"analysed":[25],"data":[26,45],"centres\u2019":[27],"optimal":[28],"operation,":[29],"workload":[30],"redistribution,":[31],"waste":[33,51],"heat":[34,52],"reuse.":[35],"addition":[37],"guaranteeing":[39],"power":[40,77],"supply":[41],"as":[42],"critical":[43],"loads,":[44],"centres":[46],"also":[47,106],"provide":[48],"the":[49,56,61,72,76,92,115,118,126],"generated":[50],"customers":[54],"via":[55],"heating":[58,99],"network.":[59],"Meanwhile,":[60],"considers":[64],"complex":[65],"interactions":[66],"of":[67,75,95,117,128],"multiple":[68,139,146],"recovery":[73],"decisions":[74],"distribution":[78],"system.":[79],"Energy":[80],"conversion":[81],"devices":[82],"electric-driven":[84],"coupling":[85,144],"components":[86],"are":[87,105],"modelled.":[88],"Even":[89],"more":[90],"importantly,":[91],"dynamic":[93],"characteristics":[94],"natural":[96],"gas":[97],"systems,":[100],"which":[101],"cannot":[102],"be":[103,134],"neglected,":[104],"considered":[107],"discussed":[109],"in":[110],"detail.":[111],"Case":[112],"studies":[113],"verify":[114],"effectiveness":[116],"model.":[121],"The":[122],"results":[123],"indicate":[124],"that":[125],"requires":[132],"improved":[135],"by":[136],"collaboration":[137],"between":[138],"sectors.":[140],"Considering":[141],"interdependencies":[142],"among":[145],"can":[149],"enhance":[150],"their":[151],"response":[152],"resistance":[154]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":17},{"year":2024,"cited_by_count":11},{"year":2023,"cited_by_count":11}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
