{"id":"https://openalex.org/W4285173411","doi":"https://doi.org/10.1109/tsg.2022.3176292","title":"Analytical Adequacy Evaluation for Power Consumers With UPS in Distribution Networks","display_name":"Analytical Adequacy Evaluation for Power Consumers With UPS in Distribution Networks","publication_year":2022,"publication_date":"2022-05-19","ids":{"openalex":"https://openalex.org/W4285173411","doi":"https://doi.org/10.1109/tsg.2022.3176292"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2022.3176292","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2022.3176292","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5047699538","display_name":"Pei Yong","orcid":"https://orcid.org/0000-0002-7969-5604"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Pei Yong","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-7969-5604","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070506875","display_name":"Ning Zhang","orcid":"https://orcid.org/0000-0003-0366-4657"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ning Zhang","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-0366-4657","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032165634","display_name":"Yaowang Li","orcid":"https://orcid.org/0000-0002-4100-0774"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yaowang Li","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-4100-0774","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004002384","display_name":"Qingchun Hou","orcid":"https://orcid.org/0000-0001-8334-9897"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qingchun Hou","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0001-8334-9897","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002499874","display_name":"Yuxiao Liu","orcid":"https://orcid.org/0000-0001-9109-5989"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yuxiao Liu","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0001-9109-5989","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100744119","display_name":"Song Ci","orcid":"https://orcid.org/0000-0002-6535-1974"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Song Ci","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-6535-1974","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100447205","display_name":"Chongqing Kang","orcid":"https://orcid.org/0000-0003-2296-8250"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chongqing Kang","raw_affiliation_strings":["Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-2296-8250","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, State Key Laboratory of Power Systems, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5047699538"],"corresponding_institution_ids":["https://openalex.org/I99065089"],"apc_list":null,"apc_paid":null,"fwci":2.1696,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.85739076,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"13","issue":"6","first_page":"4424","last_page":"4435"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4887259006500244},{"id":"https://openalex.org/keywords/distribution","display_name":"Distribution (mathematics)","score":0.4768696427345276},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3915499746799469},{"id":"https://openalex.org/keywords/econometrics","display_name":"Econometrics","score":0.3638131022453308},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3606548309326172},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.2810526490211487},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2698598802089691},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.229361891746521},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.0928475558757782}],"concepts":[{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4887259006500244},{"id":"https://openalex.org/C110121322","wikidata":"https://www.wikidata.org/wiki/Q865811","display_name":"Distribution (mathematics)","level":2,"score":0.4768696427345276},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3915499746799469},{"id":"https://openalex.org/C149782125","wikidata":"https://www.wikidata.org/wiki/Q160039","display_name":"Econometrics","level":1,"score":0.3638131022453308},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3606548309326172},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.2810526490211487},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2698598802089691},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.229361891746521},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0928475558757782},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2022.3176292","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2022.3176292","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.5600000023841858}],"awards":[{"id":"https://openalex.org/G3975364596","display_name":null,"funder_award_id":"U21B2002","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G5626781603","display_name":null,"funder_award_id":"TSG-01991-2021","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G7315832986","display_name":null,"funder_award_id":"52061635101","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W1502876580","https://openalex.org/W1513400187","https://openalex.org/W1963865502","https://openalex.org/W1969725356","https://openalex.org/W2003469515","https://openalex.org/W2005318779","https://openalex.org/W2078479487","https://openalex.org/W2081811844","https://openalex.org/W2121703295","https://openalex.org/W2132664787","https://openalex.org/W2133771143","https://openalex.org/W2155828222","https://openalex.org/W2165991293","https://openalex.org/W2342589853","https://openalex.org/W2394752786","https://openalex.org/W2431021797","https://openalex.org/W2497356089","https://openalex.org/W2519486590","https://openalex.org/W2769439850","https://openalex.org/W2807390197","https://openalex.org/W2891566123","https://openalex.org/W2969924073","https://openalex.org/W2998052572","https://openalex.org/W3002831802","https://openalex.org/W3007358632","https://openalex.org/W3011573018","https://openalex.org/W3027768509","https://openalex.org/W3044758249","https://openalex.org/W3157298661","https://openalex.org/W4235815388","https://openalex.org/W4309342599"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W4391913857","https://openalex.org/W2358668433","https://openalex.org/W4396701345","https://openalex.org/W2376932109","https://openalex.org/W2001405890","https://openalex.org/W4396696052"],"abstract_inverted_index":{"An":[0],"uninterruptible":[1],"power":[2,7,13,21,30,44,54,64],"supply":[3,31,65],"(UPS)":[4],"can":[5],"reduce":[6],"failure":[8,42],"loss":[9],"by":[10],"responding":[11],"to":[12,72,82],"demand":[14],"during":[15],"distribution":[16,130,165,179,188],"network":[17,74,166],"failures.":[18],"For":[19],"reliability-sensitive":[20],"consumers,":[22],"deploying":[23],"UPSs":[24,47],"is":[25,144],"a":[26,68,91,94,114,186],"solution":[27],"for":[28,121],"improving":[29],"reliability.":[32],"Nevertheless,":[33],"because":[34],"of":[35,67,90,129],"UPS":[36,95,133,158],"devices\u2019":[37,159],"energy":[38],"limits":[39],"and":[40,59,76,107,132,161,168,185],"potential":[41],"probability,":[43],"consumers":[45],"with":[46,56,70,93,152],"cannot":[48],"guarantee":[49],"100%":[50],"adequacy.":[51],"In":[52],"future":[53],"systems":[55],"frequent":[57],"reconfiguration":[58],"massive":[60],"storage":[61,78],"facilities,":[62],"the":[63,73,77,87,100,127,139,148,164,181,193],"adequacy":[66,122],"consumer":[69,92],"respect":[71],"configuration":[75,167],"capacity":[79,160],"will":[80],"need":[81],"be":[83,97],"frequently":[84],"evaluated.":[85],"Furthermore,":[86],"analytical":[88,116],"formulation":[89],"should":[96],"investigated":[98],"since":[99],"simulation-based":[101],"method":[102],"might":[103],"witness":[104],"low":[105],"efficiency":[106],"poor":[108],"convergency.":[109],"Therefore,":[110],"this":[111,155],"paper":[112,156],"proposes":[113],"novel":[115],"availability":[117,140],"index":[118,141],"calculation":[119,142],"framework":[120,125],"evaluation.":[123],"The":[124],"models":[126],"uncertainties":[128],"networks":[131],"devices":[134],"as":[135],"stochastic":[136,149],"processes.":[137],"Then,":[138],"formula":[143],"acquired":[145],"based":[146],"on":[147,176],"modeling.":[150],"Compared":[151],"existing":[153],"methods,":[154],"incorporates":[157],"characteristics.":[162],"Moreover,":[163],"protection":[169],"device":[170],"placement":[171],"are":[172],"considered.":[173],"Case":[174],"studies":[175],"an":[177],"illustrative":[178],"network,":[180],"modified":[182],"RBTS":[183],"system,":[184],"real":[187],"system":[189],"in":[190],"China":[191],"validate":[192],"proposed":[194],"method.":[195]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
