{"id":"https://openalex.org/W3214872486","doi":"https://doi.org/10.1109/tsg.2021.3121658","title":"Robust Distribution System Expansion Planning Incorporating Thermostatically-Controlled-Load Demand Response Resource","display_name":"Robust Distribution System Expansion Planning Incorporating Thermostatically-Controlled-Load Demand Response Resource","publication_year":2021,"publication_date":"2021-12-14","ids":{"openalex":"https://openalex.org/W3214872486","doi":"https://doi.org/10.1109/tsg.2021.3121658","mag":"3214872486"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2021.3121658","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2021.3121658","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091616797","display_name":"Huishi Liang","orcid":"https://orcid.org/0000-0003-3410-4898"},"institutions":[{"id":"https://openalex.org/I129604602","display_name":"The University of Sydney","ror":"https://ror.org/0384j8v12","country_code":"AU","type":"education","lineage":["https://openalex.org/I129604602"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Huishi Liang","raw_affiliation_strings":["School of Electrical and Information Engineering, The University of Sydney, Sydney, NSW, Australia"],"raw_orcid":"https://orcid.org/0000-0003-3410-4898","affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, The University of Sydney, Sydney, NSW, Australia","institution_ids":["https://openalex.org/I129604602"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000818065","display_name":"Jin Ma","orcid":"https://orcid.org/0000-0002-9912-2520"},"institutions":[{"id":"https://openalex.org/I129604602","display_name":"The University of Sydney","ror":"https://ror.org/0384j8v12","country_code":"AU","type":"education","lineage":["https://openalex.org/I129604602"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Jin Ma","raw_affiliation_strings":["School of Electrical and Information Engineering, The University of Sydney, Sydney, NSW, Australia"],"raw_orcid":"https://orcid.org/0000-0002-9912-2520","affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, The University of Sydney, Sydney, NSW, Australia","institution_ids":["https://openalex.org/I129604602"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101534216","display_name":"Jun Lin","orcid":"https://orcid.org/0000-0003-2291-309X"},"institutions":[{"id":"https://openalex.org/I129604602","display_name":"The University of Sydney","ror":"https://ror.org/0384j8v12","country_code":"AU","type":"education","lineage":["https://openalex.org/I129604602"]}],"countries":["AU"],"is_corresponding":false,"raw_author_name":"Jun Lin","raw_affiliation_strings":["School of Electrical and Information Engineering, The University of Sydney, Sydney, NSW, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, The University of Sydney, Sydney, NSW, Australia","institution_ids":["https://openalex.org/I129604602"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I129604602"],"apc_list":{"value":2045,"currency":"USD","value_usd":2045},"apc_paid":null,"fwci":1.4629,"has_fulltext":false,"cited_by_count":21,"citation_normalized_percentile":{"value":0.81317125,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":99},"biblio":{"volume":"13","issue":"1","first_page":"302","last_page":"313"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.7745689153671265},{"id":"https://openalex.org/keywords/smart-meter","display_name":"Smart meter","score":0.6963815093040466},{"id":"https://openalex.org/keywords/incentive","display_name":"Incentive","score":0.5743696093559265},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.5348955988883972},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45646750926971436},{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.4525446593761444},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.436083048582077},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.41541197896003723},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.3415707051753998},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.31862616539001465},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2791484594345093},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.1928987205028534},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.15131685137748718},{"id":"https://openalex.org/keywords/microeconomics","display_name":"Microeconomics","score":0.08442184329032898}],"concepts":[{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.7745689153671265},{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.6963815093040466},{"id":"https://openalex.org/C29122968","wikidata":"https://www.wikidata.org/wiki/Q1414816","display_name":"Incentive","level":2,"score":0.5743696093559265},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.5348955988883972},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45646750926971436},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.4525446593761444},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.436083048582077},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.41541197896003723},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.3415707051753998},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.31862616539001465},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2791484594345093},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.1928987205028534},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.15131685137748718},{"id":"https://openalex.org/C175444787","wikidata":"https://www.wikidata.org/wiki/Q39072","display_name":"Microeconomics","level":1,"score":0.08442184329032898},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2021.3121658","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2021.3121658","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.699999988079071,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G8548265125","display_name":"A Unified Framework for Resource Management in Edge-Cloud Data Centres","funder_award_id":"DP200103494","funder_id":"https://openalex.org/F4320334704","funder_display_name":"Australian Research Council"}],"funders":[{"id":"https://openalex.org/F4320334704","display_name":"Australian Research Council","ror":"https://ror.org/05mmh0f86"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1785828995","https://openalex.org/W1992153383","https://openalex.org/W2012692456","https://openalex.org/W2014078445","https://openalex.org/W2020898373","https://openalex.org/W2093606438","https://openalex.org/W2095900477","https://openalex.org/W2126635202","https://openalex.org/W2194701796","https://openalex.org/W2337060009","https://openalex.org/W2344109681","https://openalex.org/W2399796689","https://openalex.org/W2498244096","https://openalex.org/W2514245462","https://openalex.org/W2563096608","https://openalex.org/W2589384162","https://openalex.org/W2644347995","https://openalex.org/W2783167261","https://openalex.org/W2790780473","https://openalex.org/W2792207883","https://openalex.org/W2809623054","https://openalex.org/W2936799351","https://openalex.org/W2999553301","https://openalex.org/W3011400958","https://openalex.org/W4234997161"],"related_works":["https://openalex.org/W1997024178","https://openalex.org/W3018909029","https://openalex.org/W3205631650","https://openalex.org/W2353074559","https://openalex.org/W2775355700","https://openalex.org/W2246071452","https://openalex.org/W2171108821","https://openalex.org/W2023642087","https://openalex.org/W1589973774","https://openalex.org/W1498762745"],"abstract_inverted_index":{"Smart":[0],"meter":[1,82],"data":[2],"provides":[3],"rich":[4],"information":[5,78],"on":[6],"customers\u2019":[7,19,60],"energy":[8,135],"consumption":[9],"behaviors,":[10],"which":[11],"can":[12,26,101,148],"be":[13,102],"a":[14,37,42,46,112,122],"valuable":[15],"resource":[16],"for":[17,45,105],"evaluating":[18],"demand":[20],"response":[21],"(DR)":[22],"potential":[23,62],"and":[24,73,90,137],"thus":[25],"inform":[27],"the":[28,53,66,70,87,91,128,131,144,151,160,164],"distribution":[29],"system":[30],"expansion":[31,153],"planning":[32,157],"(DSEP).":[33],"This":[34],"paper":[35],"presents":[36],"novel":[38],"DSEP":[39,67,117,146],"framework":[40,125],"incorporating":[41],"data-driven":[43,166],"model":[44,147,168],"particular":[47],"type":[48],"of":[49,163],"incentive-based":[50],"DR":[51,61,88,109,138,167],"called":[52],"thermostatically-controlled-load":[54],"DR.":[55],"The":[56,84,115],"heterogeneity":[57],"in":[58,65,111,169],"individual":[59],"is":[63,95,119],"considered":[64,97],"by":[68],"leveraging":[69],"healing,":[71],"ventilation,":[72],"air":[74],"conditioning":[75],"(HVAC)":[76],"load":[77,132],"extracted":[79],"from":[80,130],"smart":[81],"data.":[83],"relationship":[85],"between":[86],"incentive":[89],"customer":[92],"participation":[93],"rate":[94],"also":[96],"so":[98],"that":[99,143],"incentives":[100],"optimally":[103],"designed":[104],"customers":[106],"with":[107],"different":[108],"potentials":[110],"differentiated":[113],"way.":[114],"overall":[116],"problem":[118],"formulated":[120],"into":[121],"robust":[123],"optimization":[124],"to":[126],"address":[127],"uncertainties":[129],"demands,":[133],"renewable":[134],"generations,":[136],"resources.":[139],"Case":[140],"studies":[141],"show":[142],"proposed":[145,165],"substantially":[149],"reduce":[150],"total":[152],"cost":[154],"over":[155],"conventional":[156],"paradigms,":[158],"demonstrating":[159],"positive":[161],"role":[162],"DSEP.":[170]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":4}],"updated_date":"2026-08-28T12:50:07.497085","created_date":"2025-10-10T00:00:00"}
