{"id":"https://openalex.org/W3207791655","doi":"https://doi.org/10.1109/tsg.2021.3118680","title":"Transient Fault Current Analysis of IIRESs Considering Controller Saturation","display_name":"Transient Fault Current Analysis of IIRESs Considering Controller Saturation","publication_year":2021,"publication_date":"2021-10-08","ids":{"openalex":"https://openalex.org/W3207791655","doi":"https://doi.org/10.1109/tsg.2021.3118680","mag":"3207791655"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2021.3118680","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2021.3118680","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014163978","display_name":"Ke Jia","orcid":"https://orcid.org/0000-0001-9140-1050"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ke Jia","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0001-9140-1050","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084052189","display_name":"Qian Liu","orcid":"https://orcid.org/0000-0003-0870-9068"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qian Liu","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-0870-9068","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035243852","display_name":"Bin Yang","orcid":"https://orcid.org/0000-0001-5963-2844"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bin Yang","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0001-5963-2844","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037151071","display_name":"Liming Zheng","orcid":"https://orcid.org/0000-0003-3179-2162"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liming Zheng","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-3179-2162","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060399294","display_name":"Yu Fang","orcid":"https://orcid.org/0000-0003-3715-0419"},"institutions":[{"id":"https://openalex.org/I4387152367","display_name":"State Grid Nanjing Power Supply Company (China)","ror":"https://ror.org/00emjrx81","country_code":null,"type":"company","lineage":["https://openalex.org/I4387152367"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yu Fang","raw_affiliation_strings":["Department of Distribution Network Operation and Maintenance, State Grid Nanjing Power Supply Company, Nanjing, China"],"raw_orcid":"https://orcid.org/0000-0003-3715-0419","affiliations":[{"raw_affiliation_string":"Department of Distribution Network Operation and Maintenance, State Grid Nanjing Power Supply Company, Nanjing, China","institution_ids":["https://openalex.org/I4387152367"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5077234408","display_name":"Tianshu Bi","orcid":"https://orcid.org/0000-0002-3555-9045"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tianshu Bi","raw_affiliation_strings":["State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-3555-9045","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.348,"has_fulltext":false,"cited_by_count":53,"citation_normalized_percentile":{"value":0.95180233,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"13","issue":"1","first_page":"496","last_page":"504"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.7452089786529541},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6935023069381714},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6801599860191345},{"id":"https://openalex.org/keywords/stuck-at-fault","display_name":"Stuck-at fault","score":0.5687905550003052},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5273930430412292},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5032796263694763},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.49548208713531494},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.4709775447845459},{"id":"https://openalex.org/keywords/fault-coverage","display_name":"Fault coverage","score":0.4558471739292145},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.4518515467643738},{"id":"https://openalex.org/keywords/time-domain","display_name":"Time domain","score":0.42755427956581116},{"id":"https://openalex.org/keywords/fault-current-limiter","display_name":"Fault current limiter","score":0.41185060143470764},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3752831518650055},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.36305102705955505},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.33065375685691833},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.32036203145980835},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.3036457300186157},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2119433879852295},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.13028791546821594},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.1043720543384552},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1029549241065979},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.0700635015964508}],"concepts":[{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7452089786529541},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6935023069381714},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6801599860191345},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.5687905550003052},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5273930430412292},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5032796263694763},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.49548208713531494},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.4709775447845459},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.4558471739292145},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.4518515467643738},{"id":"https://openalex.org/C103824480","wikidata":"https://www.wikidata.org/wiki/Q185889","display_name":"Time domain","level":2,"score":0.42755427956581116},{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.41185060143470764},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3752831518650055},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.36305102705955505},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.33065375685691833},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32036203145980835},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3036457300186157},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2119433879852295},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.13028791546821594},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.1043720543384552},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1029549241065979},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0700635015964508},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2021.3118680","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2021.3118680","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8600000143051147}],"awards":[{"id":"https://openalex.org/G1737743232","display_name":null,"funder_award_id":"51725702","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G539381461","display_name":null,"funder_award_id":"51777071","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W1537799825","https://openalex.org/W2044839280","https://openalex.org/W2047737781","https://openalex.org/W2073283302","https://openalex.org/W2082954821","https://openalex.org/W2101645211","https://openalex.org/W2118613401","https://openalex.org/W2238280276","https://openalex.org/W2313297961","https://openalex.org/W2345765321","https://openalex.org/W2517795611","https://openalex.org/W2524139230","https://openalex.org/W2567896591","https://openalex.org/W2638559990","https://openalex.org/W2755451687","https://openalex.org/W2784066998","https://openalex.org/W2786776441","https://openalex.org/W2802535136","https://openalex.org/W2805690866","https://openalex.org/W2884174731","https://openalex.org/W2891339011","https://openalex.org/W2912602224","https://openalex.org/W2946171209","https://openalex.org/W2964122328","https://openalex.org/W2975895496","https://openalex.org/W3009878705","https://openalex.org/W3033695985","https://openalex.org/W3049608682","https://openalex.org/W3081100854","https://openalex.org/W3093853041","https://openalex.org/W3116895642","https://openalex.org/W3176922402"],"related_works":["https://openalex.org/W2024194466","https://openalex.org/W3148663848","https://openalex.org/W3186790058","https://openalex.org/W2051500795","https://openalex.org/W2163103195","https://openalex.org/W1978303825","https://openalex.org/W4210447066","https://openalex.org/W1974225921","https://openalex.org/W2390533148","https://openalex.org/W2386936363"],"abstract_inverted_index":{"Fault":[0],"characteristics":[1],"analysis":[2,15],"normally":[3],"provides":[4],"a":[5,53,127],"theoretical":[6],"foundation":[7],"for":[8],"the":[9,27,35,42,57,69,90,95,98,114,119,132,136,153,159,170,185,188],"protection":[10,43],"design.":[11],"Although":[12],"conventional":[13],"fault":[14,36,46,58,103,133,147],"of":[16,60,72,82,94,118,131,187],"inverter-interfaced":[17],"renewable":[18],"energy":[19],"sources":[20],"(IIRESs)":[21],"can":[22,39],"characterize":[23],"post-fault":[24],"steady-state":[25],"at":[26,165],"power":[28],"frequency,":[29],"it":[30],"might":[31],"not":[32],"effectively":[33],"present":[34],"transient.":[37],"This":[38],"negatively":[40],"affect":[41],"based":[44],"on":[45],"transient":[47,59,102,129],"data":[48,179],"within":[49,97],"20\u201330":[50],"ms":[51],"after":[52],"grid":[54],"fault.":[55],"Thus,":[56],"IIRESs":[61],"needs":[62],"to":[63,88,169,183],"be":[64],"fully":[65],"investigated.":[66],"Given":[67],"this,":[68],"nonlinear":[70,115],"effect":[71],"controller":[73,96,120],"saturation":[74],"is":[75,85,108,139,162],"considered":[76],"in":[77,111,145,173],"this":[78],"study.":[79],"The":[80,101],"domain":[81],"attraction":[83],"(DOA)":[84],"first":[86],"established":[87],"estimate":[89],"practical":[91],"working":[92,123],"state":[93],"current":[99,104],"loop.":[100],"(TFC)":[105],"analytical":[106,155,191],"model":[107,138],"then":[109],"proposed":[110,137,160,189],"accordance":[112],"with":[113],"control":[116],"response":[117],"under":[121],"different":[122,146],"stages,":[124],"which":[125],"reveals":[126],"detailed":[128],"transition":[130],"current.":[134],"Meanwhile,":[135],"low-order":[140],"and":[141],"presents":[142],"high":[143],"applicability":[144],"scenarios.":[148],"Simulation":[149],"results":[150],"indicate":[151],"that":[152],"TFC":[154,190],"accuracy":[156,171],"obtained":[157],"using":[158],"method":[161],"improved":[163],"by":[164],"most":[166],"50%":[167],"relative":[168],"reported":[172],"published":[174],"studies.":[175],"Field":[176],"short-circuit":[177],"test":[178],"are":[180],"ultimately":[181],"used":[182],"verify":[184],"performance":[186],"model.":[192]},"counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":8},{"year":2024,"cited_by_count":20},{"year":2023,"cited_by_count":13},{"year":2022,"cited_by_count":7}],"updated_date":"2026-07-29T09:40:50.615796","created_date":"2025-10-10T00:00:00"}
