{"id":"https://openalex.org/W3008059000","doi":"https://doi.org/10.1109/tsg.2020.2977207","title":"Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks","display_name":"Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks","publication_year":2020,"publication_date":"2020-02-28","ids":{"openalex":"https://openalex.org/W3008059000","doi":"https://doi.org/10.1109/tsg.2020.2977207","mag":"3008059000"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2020.2977207","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2020.2977207","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://www.osti.gov/biblio/1907398","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100461642","display_name":"Bo Liu","orcid":"https://orcid.org/0000-0002-2965-7714"},"institutions":[{"id":"https://openalex.org/I189590672","display_name":"Kansas State University","ror":"https://ror.org/05p1j8758","country_code":"US","type":"education","lineage":["https://openalex.org/I189590672"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Bo Liu","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Kansas State University, Manhattan, USA"],"raw_orcid":"https://orcid.org/0000-0002-2965-7714","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Kansas State University, Manhattan, USA","institution_ids":["https://openalex.org/I189590672"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5030552258","display_name":"Hongyu Wu","orcid":"https://orcid.org/0000-0002-5223-6635"},"institutions":[{"id":"https://openalex.org/I189590672","display_name":"Kansas State University","ror":"https://ror.org/05p1j8758","country_code":"US","type":"education","lineage":["https://openalex.org/I189590672"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hongyu Wu","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Kansas State University, Manhattan, USA"],"raw_orcid":"https://orcid.org/0000-0002-5223-6635","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Kansas State University, Manhattan, USA","institution_ids":["https://openalex.org/I189590672"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I189590672"],"apc_list":null,"apc_paid":null,"fwci":6.8512,"has_fulltext":false,"cited_by_count":88,"citation_normalized_percentile":{"value":0.97441636,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":100},"biblio":{"volume":"11","issue":"5","first_page":"4345","last_page":"4357"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9901999831199646,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10400","display_name":"Network Security and Intrusion Detection","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reactance","display_name":"Reactance","score":0.6121507287025452},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5908137559890747},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.43586212396621704},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.4312286078929901},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.4123545289039612},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.393794983625412},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.3643041253089905},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3541577458381653},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.33040326833724976},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.3253384232521057},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.32362180948257446},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.2629789710044861},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.2016151249408722},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.1236242949962616},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12060204148292542}],"concepts":[{"id":"https://openalex.org/C176661527","wikidata":"https://www.wikidata.org/wiki/Q746935","display_name":"Reactance","level":3,"score":0.6121507287025452},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5908137559890747},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43586212396621704},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.4312286078929901},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.4123545289039612},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.393794983625412},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.3643041253089905},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3541577458381653},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.33040326833724976},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.3253384232521057},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.32362180948257446},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.2629789710044861},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.2016151249408722},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1236242949962616},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12060204148292542},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2020.2977207","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2020.2977207","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:osti.gov:1907398","is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/1907398","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:osti.gov:1907398","is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/1907398","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/16","display_name":"Peace, Justice and strong institutions","score":0.7400000095367432}],"awards":[{"id":"https://openalex.org/G2510601149","display_name":null,"funder_award_id":"TSG-01121-2019","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"},{"id":"https://openalex.org/G6662488201","display_name":"RII Track-4: Robust Matrix Completion State Estimation in Low-Observability Distribution Systems under False Data Injection Attacks","funder_award_id":"1929147","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"}],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W157211085","https://openalex.org/W574738980","https://openalex.org/W1499880919","https://openalex.org/W1984961651","https://openalex.org/W1998285730","https://openalex.org/W2022810949","https://openalex.org/W2031252608","https://openalex.org/W2038651258","https://openalex.org/W2039148409","https://openalex.org/W2066909550","https://openalex.org/W2087216833","https://openalex.org/W2106424475","https://openalex.org/W2110954114","https://openalex.org/W2129034289","https://openalex.org/W2147320153","https://openalex.org/W2150153963","https://openalex.org/W2319367234","https://openalex.org/W2434545073","https://openalex.org/W2503917224","https://openalex.org/W2510829002","https://openalex.org/W2543274172","https://openalex.org/W2550453031","https://openalex.org/W2571293944","https://openalex.org/W2762210062","https://openalex.org/W2766507147","https://openalex.org/W2783169723","https://openalex.org/W2807999445","https://openalex.org/W2905961907","https://openalex.org/W2963130331","https://openalex.org/W2965880414","https://openalex.org/W2991102815","https://openalex.org/W2998298992"],"related_works":["https://openalex.org/W4298001173","https://openalex.org/W4206156853","https://openalex.org/W2137158307","https://openalex.org/W3091362923","https://openalex.org/W2791359615","https://openalex.org/W2315510390","https://openalex.org/W2171781874","https://openalex.org/W2152290689","https://openalex.org/W2912954116","https://openalex.org/W2155742919"],"abstract_inverted_index":{"Moving":[0],"target":[1],"defense":[2,6],"(MTD)":[3],"is":[4,105,147,152],"a":[5,36,72,81,156],"strategy":[7],"to":[8,34,86,129,154],"detect":[9],"stealthy":[10],"false":[11],"data":[12],"injection":[13],"(FDI)":[14],"attacks":[15],"against":[16],"the":[17,42,68,89,92,97,108,113,123,131,142,159,163,177,182,189],"power":[18],"system":[19,27,160],"state":[20],"estimation":[21],"using":[22,80,122,181],"distributed":[23],"flexible":[24],"AC":[25],"transmission":[26],"(D-FACTS)":[28],"devices.":[29,54],"However,":[30],"existing":[31],"studies":[32],"neglect":[33],"address":[35],"fundamental":[37],"yet":[38],"critical":[39],"issue,":[40],"i.e.,":[41],"D-FACTS":[43,53,69,94,118,127,145,184],"placement,":[44],"by":[45,121],"assuming":[46],"that":[47,88],"all":[48],"lines":[49,146],"are":[50],"equipped":[51],"with":[52],"To":[55],"tackle":[56],"this":[57],"problem,":[58],"we":[59,76,116],"first":[60],"derive":[61],"analytical":[62,114],"necessary":[63],"conditions":[64,79],"and":[65,162,172,193],"requirements":[66],"on":[67,112,168],"placement":[70,95,119,185],"for":[71],"complete":[73],"MTD.":[74],"Further,":[75],"propose":[77],"sufficient":[78],"graph":[82],"theory-based":[83],"topology":[84],"analysis":[85],"ensure":[87],"MTD":[90,109,133,164],"under":[91],"proposed":[93,153,183],"has":[96],"maximum":[98,132],"rank":[99,192],"of":[100,107,126,144,179],"its":[101],"composite":[102,190],"matrix,":[103],"which":[104,141],"indicative":[106],"effectiveness.":[110,134,165],"Based":[111],"conditions,":[115],"design":[117],"algorithms":[120,186],"minimum":[124],"number":[125],"devices":[128],"achieve":[130],"A":[135],"novel":[136],"MTD-based":[137],"ACOPF":[138],"model,":[139],"in":[140,187],"reactance":[143],"introduced":[148],"as":[149],"decision":[150],"variables,":[151],"find":[155],"trade-off":[157],"between":[158],"loss":[161],"Numerical":[166],"results":[167],"6-bus,":[169],"IEEE":[170,173],"14-bus,":[171],"118-bus":[174],"systems":[175],"show":[176],"efficacy":[178],"MTDs":[180],"maximizing":[188],"matrix":[191],"detecting":[194],"FDI":[195],"attacks.":[196]},"counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":20},{"year":2024,"cited_by_count":16},{"year":2023,"cited_by_count":13},{"year":2022,"cited_by_count":19},{"year":2021,"cited_by_count":10},{"year":2020,"cited_by_count":5}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
