{"id":"https://openalex.org/W2950016236","doi":"https://doi.org/10.1109/tsg.2019.2924295","title":"Grid-Synchronization Stability Analysis and Loop Shaping for PLL-Based Power Converters With Different Reactive Power Control","display_name":"Grid-Synchronization Stability Analysis and Loop Shaping for PLL-Based Power Converters With Different Reactive Power Control","publication_year":2019,"publication_date":"2019-06-21","ids":{"openalex":"https://openalex.org/W2950016236","doi":"https://doi.org/10.1109/tsg.2019.2924295","mag":"2950016236"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2019.2924295","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2019.2924295","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5019393760","display_name":"Linbin Huang","orcid":"https://orcid.org/0000-0002-5892-0374"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Linbin Huang","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering Zhejiang University,HangZhou,China"],"raw_orcid":"https://orcid.org/0000-0002-5892-0374","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering Zhejiang University,HangZhou,China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086421717","display_name":"Huanhai Xin","orcid":"https://orcid.org/0000-0001-5327-1371"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Huanhai Xin","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering Zhejiang University,HangZhou,China"],"raw_orcid":"https://orcid.org/0000-0001-5327-1371","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering Zhejiang University,HangZhou,China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100779406","display_name":"Zhiyi Li","orcid":"https://orcid.org/0000-0001-7498-8005"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiyi Li","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering Zhejiang University,HangZhou,China"],"raw_orcid":"https://orcid.org/0000-0001-7498-8005","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering Zhejiang University,HangZhou,China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056099862","display_name":"Ping Ju","orcid":"https://orcid.org/0000-0002-2412-7570"},"institutions":[{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]},{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ping Ju","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","State Grid Zhejiang Electric Power Company, Ltd., Hangzhou, China","College of Electrical Engineering, Zhejiang University, Hangzhou, China; State Grid Zhejiang Electric Power Company, Ltd., Hangzhou, China"],"raw_orcid":"https://orcid.org/0000-0002-2412-7570","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"State Grid Zhejiang Electric Power Company, Ltd., Hangzhou, China","institution_ids":[]},{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China; State Grid Zhejiang Electric Power Company, Ltd., Hangzhou, China","institution_ids":["https://openalex.org/I4210126065","https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087539302","display_name":"Hui Yuan","orcid":"https://orcid.org/0000-0003-0580-2486"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hui Yuan","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering Zhejiang University,HangZhou,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering Zhejiang University,HangZhou,China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053163831","display_name":"Lan Zhou","orcid":"https://orcid.org/0000-0002-8136-5153"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhou Lan","raw_affiliation_strings":["State Grid Zhejiang Electric Power Company, Ltd., Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Company, Ltd., Hangzhou, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100422284","display_name":"Zhen Wang","orcid":"https://orcid.org/0000-0001-9209-673X"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhen Wang","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering Zhejiang University,HangZhou,China"],"raw_orcid":"https://orcid.org/0000-0001-9209-673X","affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering Zhejiang University,HangZhou,China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":16.0182,"has_fulltext":false,"cited_by_count":241,"citation_normalized_percentile":{"value":0.99421627,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":100},"biblio":{"volume":"11","issue":"1","first_page":"501","last_page":"516"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9850999712944031,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9740999937057495,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/phase-locked-loop","display_name":"Phase-locked loop","score":0.8432774543762207},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.8181431293487549},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.6070507168769836},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5845873355865479},{"id":"https://openalex.org/keywords/feed-forward","display_name":"Feed forward","score":0.5300295948982239},{"id":"https://openalex.org/keywords/transfer-function","display_name":"Transfer function","score":0.48754996061325073},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.4735773503780365},{"id":"https://openalex.org/keywords/phase-margin","display_name":"Phase margin","score":0.46273788809776306},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4523717164993286},{"id":"https://openalex.org/keywords/maximum-power-transfer-theorem","display_name":"Maximum power transfer theorem","score":0.45208704471588135},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4366086721420288},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.41149812936782837},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3178841471672058},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.31624823808670044},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.28460240364074707},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.2302306592464447},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.22421881556510925},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1685800552368164},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.09176042675971985},{"id":"https://openalex.org/keywords/jitter","display_name":"Jitter","score":0.07216179370880127},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.06670519709587097},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.06669330596923828}],"concepts":[{"id":"https://openalex.org/C12707504","wikidata":"https://www.wikidata.org/wiki/Q52637","display_name":"Phase-locked loop","level":3,"score":0.8432774543762207},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.8181431293487549},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.6070507168769836},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5845873355865479},{"id":"https://openalex.org/C38858127","wikidata":"https://www.wikidata.org/wiki/Q5441228","display_name":"Feed forward","level":2,"score":0.5300295948982239},{"id":"https://openalex.org/C81299745","wikidata":"https://www.wikidata.org/wiki/Q334269","display_name":"Transfer function","level":2,"score":0.48754996061325073},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4735773503780365},{"id":"https://openalex.org/C81455027","wikidata":"https://www.wikidata.org/wiki/Q7180955","display_name":"Phase margin","level":5,"score":0.46273788809776306},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4523717164993286},{"id":"https://openalex.org/C67186554","wikidata":"https://www.wikidata.org/wiki/Q17103352","display_name":"Maximum power transfer theorem","level":3,"score":0.45208704471588135},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4366086721420288},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.41149812936782837},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3178841471672058},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.31624823808670044},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.28460240364074707},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.2302306592464447},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.22421881556510925},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1685800552368164},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.09176042675971985},{"id":"https://openalex.org/C134652429","wikidata":"https://www.wikidata.org/wiki/Q1052698","display_name":"Jitter","level":2,"score":0.07216179370880127},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.06670519709587097},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.06669330596923828},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C145366948","wikidata":"https://www.wikidata.org/wiki/Q178947","display_name":"Operational amplifier","level":4,"score":0.0},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2019.2924295","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2019.2924295","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.7799999713897705}],"awards":[{"id":"https://openalex.org/G3314170728","display_name":null,"funder_award_id":"521104190005","funder_id":"https://openalex.org/F4320335967","funder_display_name":"Science and Technology Project of State Grid"}],"funders":[{"id":"https://openalex.org/F4320335967","display_name":"Science and Technology Project of State Grid","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":48,"referenced_works":["https://openalex.org/W1101194588","https://openalex.org/W1548971333","https://openalex.org/W1578978182","https://openalex.org/W1974967408","https://openalex.org/W1994959046","https://openalex.org/W2001965107","https://openalex.org/W2007949701","https://openalex.org/W2031178401","https://openalex.org/W2044621120","https://openalex.org/W2072513313","https://openalex.org/W2073017797","https://openalex.org/W2079261605","https://openalex.org/W2103457274","https://openalex.org/W2112242185","https://openalex.org/W2124074876","https://openalex.org/W2130358341","https://openalex.org/W2139361710","https://openalex.org/W2141507550","https://openalex.org/W2143743846","https://openalex.org/W2151903076","https://openalex.org/W2163501722","https://openalex.org/W2233092188","https://openalex.org/W2292974228","https://openalex.org/W2319578877","https://openalex.org/W2330294603","https://openalex.org/W2345471895","https://openalex.org/W2345765321","https://openalex.org/W2543769077","https://openalex.org/W2610075340","https://openalex.org/W2610528666","https://openalex.org/W2623267614","https://openalex.org/W2682389990","https://openalex.org/W2750703600","https://openalex.org/W2765276520","https://openalex.org/W2776114286","https://openalex.org/W2809004868","https://openalex.org/W2897139880","https://openalex.org/W2897945531","https://openalex.org/W2898521189","https://openalex.org/W2898699473","https://openalex.org/W2899341896","https://openalex.org/W2906518190","https://openalex.org/W2943395887","https://openalex.org/W2962861585","https://openalex.org/W4238110342","https://openalex.org/W6627048627","https://openalex.org/W6632881671","https://openalex.org/W6739666160"],"related_works":["https://openalex.org/W1576949837","https://openalex.org/W2286391053","https://openalex.org/W2636385491","https://openalex.org/W2286539782","https://openalex.org/W2003092572","https://openalex.org/W2733305512","https://openalex.org/W3171387815","https://openalex.org/W2774518358","https://openalex.org/W2597935862","https://openalex.org/W2510067771"],"abstract_inverted_index":{"Power":[0],"converters":[1],"may":[2],"lose":[3],"synchronization":[4],"with":[5,68],"the":[6,26,36,46,65,69,73,84,92,98,109,144,160,169,175,182],"remaining":[7],"network":[8],"when":[9],"integrated":[10],"in":[11,76,167,189],"a":[12,58],"weak":[13],"power":[14,38,50],"grid.":[15],"Such":[16],"an":[17],"instability":[18,23],"phenomenon":[19],"[known":[20],"as":[21],"grid-synchronization":[22],"(GSI)]":[24],"features":[25],"frequency":[27],"divergence":[28],"of":[29,35,48,72,78,91,125,146,163,181],"phase-locked":[30],"loop":[31,161],"(PLL)":[32],"and":[33,88,114,118,127,153,172],"oscillations":[34],"converter's":[37],"output.":[39],"In":[40,155],"this":[41],"paper,":[42],"we":[43,96,106,157],"focus":[44],"on":[45,54,108],"influences":[47],"reactive":[49],"control":[51,148],"(RPC)":[52],"methods":[53,124],"GSI.":[55,178],"We":[56],"develop":[57],"single-input-single-output":[59],"model":[60],"to":[61,131],"explicitly":[62],"reveal":[63],"how":[64,159],"PLL":[66,164],"interacts":[67],"other":[70],"parts":[71],"converter":[74,94,176],"system":[75],"terms":[77],"grid":[79],"synchronization.":[80],"Then,":[81],"after":[82],"deriving":[83],"open-loop":[85],"transfer":[86],"function":[87,90],"sensitivity":[89],"entire":[93],"system,":[95],"compare":[97],"stability":[99,133,137,170,183],"margins":[100],"for":[101,142],"different":[102,122,132],"RPC":[103,126],"methods.":[104],"Furthermore,":[105],"elaborate":[107],"interactions":[110],"among":[111],"RPC,":[112,151],"PLL,":[113],"voltage":[115],"feedforward":[116],"(VFF),":[117],"then":[119],"demonstrate":[120,158],"that":[121],"design":[123,145],"VFF":[128,152],"will":[129],"lead":[130],"margins.":[134],"The":[135,179],"subsequent":[136],"analysis":[138,184],"provides":[139],"insightful":[140],"guidelines":[141],"coordinating":[143],"multiple":[147],"loops,":[149],"i.e.,":[150],"PLL.":[154],"particular,":[156],"shaping":[162],"takes":[165],"effect":[166],"increasing":[168],"margin":[171],"eventually":[173],"preventing":[174],"from":[177],"validity":[180],"is":[185],"verified":[186],"through":[187],"simulations":[188],"MATLAB/Simulink.":[190]},"counts_by_year":[{"year":2026,"cited_by_count":9},{"year":2025,"cited_by_count":39},{"year":2024,"cited_by_count":50},{"year":2023,"cited_by_count":48},{"year":2022,"cited_by_count":42},{"year":2021,"cited_by_count":28},{"year":2020,"cited_by_count":19},{"year":2019,"cited_by_count":6}],"updated_date":"2026-06-12T08:23:45.883708","created_date":"2025-10-10T00:00:00"}
