{"id":"https://openalex.org/W2922251527","doi":"https://doi.org/10.1109/tsg.2019.2905348","title":"Data-Driven Local Control Design for Active Distribution Grids Using Off-Line Optimal Power Flow and Machine Learning Techniques","display_name":"Data-Driven Local Control Design for Active Distribution Grids Using Off-Line Optimal Power Flow and Machine Learning Techniques","publication_year":2019,"publication_date":"2019-03-15","ids":{"openalex":"https://openalex.org/W2922251527","doi":"https://doi.org/10.1109/tsg.2019.2905348","mag":"2922251527"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2019.2905348","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2019.2905348","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["arxiv","crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/1808.01009","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5038638408","display_name":"Stavros Karagiannopoulos","orcid":"https://orcid.org/0000-0002-0135-2230"},"institutions":[{"id":"https://openalex.org/I35440088","display_name":"ETH Zurich","ror":"https://ror.org/05a28rw58","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I35440088"]}],"countries":["CH"],"is_corresponding":true,"raw_author_name":"Stavros Karagiannopoulos","raw_affiliation_strings":["Power Systems Laboratory, ETH Zurich, Z\u00fcrich, Switzerland"],"affiliations":[{"raw_affiliation_string":"Power Systems Laboratory, ETH Zurich, Z\u00fcrich, Switzerland","institution_ids":["https://openalex.org/I35440088"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013476904","display_name":"Petros Aristidou","orcid":"https://orcid.org/0000-0003-4429-0225"},"institutions":[{"id":"https://openalex.org/I130828816","display_name":"University of Leeds","ror":"https://ror.org/024mrxd33","country_code":"GB","type":"education","lineage":["https://openalex.org/I130828816"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Petros Aristidou","raw_affiliation_strings":["School of Electronic and Electrical Engineering, University of Leeds, Leeds, U.K"],"affiliations":[{"raw_affiliation_string":"School of Electronic and Electrical Engineering, University of Leeds, Leeds, U.K","institution_ids":["https://openalex.org/I130828816"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5029570783","display_name":"Gabriela Hug","orcid":"https://orcid.org/0000-0002-4312-616X"},"institutions":[{"id":"https://openalex.org/I35440088","display_name":"ETH Zurich","ror":"https://ror.org/05a28rw58","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I35440088"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Gabriela Hug","raw_affiliation_strings":["Power Systems Laboratory, ETH Zurich, Z\u00fcrich, Switzerland"],"affiliations":[{"raw_affiliation_string":"Power Systems Laboratory, ETH Zurich, Z\u00fcrich, Switzerland","institution_ids":["https://openalex.org/I35440088"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5038638408"],"corresponding_institution_ids":["https://openalex.org/I35440088"],"apc_list":null,"apc_paid":null,"fwci":10.1295,"has_fulltext":false,"cited_by_count":157,"citation_normalized_percentile":{"value":0.98701071,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":100},"biblio":{"volume":"10","issue":"6","first_page":"6461","last_page":"6471"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6310420036315918},{"id":"https://openalex.org/keywords/optimal-control","display_name":"Optimal control","score":0.5304866433143616},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.5153012275695801},{"id":"https://openalex.org/keywords/power-flow","display_name":"Power flow","score":0.472027450799942},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4274553060531616},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.41841840744018555},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3902990221977234},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.37602752447128296},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.3482731580734253},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3210335373878479},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.29202163219451904},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.2292504608631134}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6310420036315918},{"id":"https://openalex.org/C91575142","wikidata":"https://www.wikidata.org/wiki/Q1971426","display_name":"Optimal control","level":2,"score":0.5304866433143616},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.5153012275695801},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.472027450799942},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4274553060531616},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.41841840744018555},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3902990221977234},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.37602752447128296},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3482731580734253},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3210335373878479},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.29202163219451904},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.2292504608631134},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.1109/tsg.2019.2905348","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2019.2905348","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:eprints.whiterose.ac.uk:143765","is_oa":false,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4306400854","display_name":"White Rose Research Online (University of Leeds, The University of Sheffield, University of York)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I2800616092","host_organization_name":"White Rose University Consortium","host_organization_lineage":["https://openalex.org/I2800616092"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"Article"},{"id":"pmh:oai:arXiv.org:1808.01009","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1808.01009","pdf_url":"https://arxiv.org/pdf/1808.01009","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},{"id":"pmh:oai:ktisis.cut.ac.cy:20.500.14279/18088","is_oa":false,"landing_page_url":"http://arxiv.org/abs/1808.01009v2","pdf_url":null,"source":{"id":"https://openalex.org/S4306400897","display_name":"Ktisis at Cyprus University of Technology (Cyprus University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I163151358","host_organization_name":"Cyprus University of Technology","host_organization_lineage":["https://openalex.org/I163151358"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:1808.01009","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1808.01009","pdf_url":"https://arxiv.org/pdf/1808.01009","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6200000047683716,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":48,"referenced_works":["https://openalex.org/W1497256145","https://openalex.org/W1541786028","https://openalex.org/W1554944419","https://openalex.org/W1974059941","https://openalex.org/W1997135619","https://openalex.org/W2000587848","https://openalex.org/W2007423841","https://openalex.org/W2071227862","https://openalex.org/W2088896352","https://openalex.org/W2121876331","https://openalex.org/W2136464549","https://openalex.org/W2137346077","https://openalex.org/W2141380252","https://openalex.org/W2143022361","https://openalex.org/W2153332004","https://openalex.org/W2171033594","https://openalex.org/W2182958716","https://openalex.org/W2286169807","https://openalex.org/W2339497397","https://openalex.org/W2494074628","https://openalex.org/W2536620281","https://openalex.org/W2542143421","https://openalex.org/W2553606313","https://openalex.org/W2554465867","https://openalex.org/W2564233542","https://openalex.org/W2565898372","https://openalex.org/W2611124040","https://openalex.org/W2625248137","https://openalex.org/W2724266916","https://openalex.org/W2759018988","https://openalex.org/W2807975741","https://openalex.org/W2858763343","https://openalex.org/W2889222609","https://openalex.org/W2926112489","https://openalex.org/W2951074724","https://openalex.org/W2963289369","https://openalex.org/W2964070407","https://openalex.org/W3098010617","https://openalex.org/W3100598929","https://openalex.org/W3106327698","https://openalex.org/W3143127938","https://openalex.org/W4247227590","https://openalex.org/W4256550092","https://openalex.org/W4298330402","https://openalex.org/W6629703760","https://openalex.org/W6680235779","https://openalex.org/W6744764230","https://openalex.org/W6761237432"],"related_works":["https://openalex.org/W1892002403","https://openalex.org/W4309005041","https://openalex.org/W2962746246","https://openalex.org/W1989531755","https://openalex.org/W1967384683","https://openalex.org/W2892237068","https://openalex.org/W1901119619","https://openalex.org/W2058275692","https://openalex.org/W2378727206","https://openalex.org/W2040290816"],"abstract_inverted_index":{"The":[0,92],"optimal":[1,68],"control":[2,84,104],"of":[3,18,26,39,73,80],"distribution":[4,21,90],"networks":[5],"often":[6],"requires":[7],"monitoring":[8],"and":[9,28,57,105],"communication":[10],"infrastructure,":[11],"either":[12],"centralized":[13],"or":[14],"distributed.":[15],"However,":[16],"most":[17],"the":[19,37,40,67,71,78,81],"current":[20],"systems":[22],"lack":[23],"this":[24,43],"kind":[25],"infrastructure":[27],"rely":[29],"on":[30,85],"sub-optimal,":[31],"fit-and-forget,":[32],"local":[33,63,83,103],"controls":[34,64],"to":[35,61],"ensure":[36],"security":[38],"network.":[41,91],"In":[42],"paper,":[44],"we":[45],"propose":[46],"a":[47,86],"data-driven":[48,97],"algorithm":[49],"that":[50,65,95],"uses":[51],"historical":[52],"data,":[53],"advanced":[54],"optimization":[55],"techniques,":[56],"machine":[58],"learning":[59],"methods":[60],"design":[62],"emulate":[66],"behavior":[69],"without":[70],"use":[72],"any":[74],"communication.":[75],"We":[76],"demonstrate":[77],"performance":[79],"optimized":[82],"three-phase,":[87],"unbalanced,":[88],"low-voltage,":[89],"results":[93],"show":[94],"our":[96],"methodology":[98],"clearly":[99],"outperforms":[100],"standard":[101],"industry":[102],"successfully":[106],"imitates":[107],"an":[108],"optimal-power-flow-based":[109],"control.":[110]},"counts_by_year":[{"year":2025,"cited_by_count":17},{"year":2024,"cited_by_count":27},{"year":2023,"cited_by_count":28},{"year":2022,"cited_by_count":28},{"year":2021,"cited_by_count":24},{"year":2020,"cited_by_count":22},{"year":2019,"cited_by_count":10},{"year":2018,"cited_by_count":1}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2019-03-22T00:00:00"}