{"id":"https://openalex.org/W2914966552","doi":"https://doi.org/10.1109/tsg.2019.2896211","title":"A Fault-Tolerance Based Approach to Optimal PMU Placement","display_name":"A Fault-Tolerance Based Approach to Optimal PMU Placement","publication_year":2019,"publication_date":"2019-01-30","ids":{"openalex":"https://openalex.org/W2914966552","doi":"https://doi.org/10.1109/tsg.2019.2896211","mag":"2914966552"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2019.2896211","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2019.2896211","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084158339","display_name":"Saleh Almasabi","orcid":"https://orcid.org/0000-0003-4653-190X"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Saleh Almasabi","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA"],"raw_orcid":"https://orcid.org/0000-0003-4653-190X","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","institution_ids":["https://openalex.org/I87216513"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035972401","display_name":"Joydeep Mitra","orcid":"https://orcid.org/0000-0001-9287-0983"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Joydeep Mitra","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA"],"raw_orcid":"https://orcid.org/0000-0001-9287-0983","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA","institution_ids":["https://openalex.org/I87216513"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.0586,"has_fulltext":false,"cited_by_count":31,"citation_normalized_percentile":{"value":0.87027342,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":98},"biblio":{"volume":"10","issue":"6","first_page":"6070","last_page":"6079"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/observability","display_name":"Observability","score":0.9007907509803772},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.7702186107635498},{"id":"https://openalex.org/keywords/installation","display_name":"Installation","score":0.6835496425628662},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.6181093454360962},{"id":"https://openalex.org/keywords/units-of-measurement","display_name":"Units of measurement","score":0.5716339349746704},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.550740659236908},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4865647852420807},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4838191866874695},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.45454639196395874},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4421820044517517},{"id":"https://openalex.org/keywords/vulnerability","display_name":"Vulnerability (computing)","score":0.4372841715812683},{"id":"https://openalex.org/keywords/phasor-measurement-unit","display_name":"Phasor measurement unit","score":0.42117446660995483},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.41320011019706726},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4033387005329132},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.251448392868042},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.13540074229240417}],"concepts":[{"id":"https://openalex.org/C36299963","wikidata":"https://www.wikidata.org/wiki/Q1369844","display_name":"Observability","level":2,"score":0.9007907509803772},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7702186107635498},{"id":"https://openalex.org/C146778888","wikidata":"https://www.wikidata.org/wiki/Q836862","display_name":"Installation","level":2,"score":0.6835496425628662},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.6181093454360962},{"id":"https://openalex.org/C151233233","wikidata":"https://www.wikidata.org/wiki/Q47574","display_name":"Units of measurement","level":2,"score":0.5716339349746704},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.550740659236908},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4865647852420807},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4838191866874695},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.45454639196395874},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4421820044517517},{"id":"https://openalex.org/C95713431","wikidata":"https://www.wikidata.org/wiki/Q631425","display_name":"Vulnerability (computing)","level":2,"score":0.4372841715812683},{"id":"https://openalex.org/C2778229166","wikidata":"https://www.wikidata.org/wiki/Q8290","display_name":"Phasor measurement unit","level":5,"score":0.42117446660995483},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.41320011019706726},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4033387005329132},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.251448392868042},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.13540074229240417},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C28826006","wikidata":"https://www.wikidata.org/wiki/Q33521","display_name":"Applied mathematics","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2019.2896211","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2019.2896211","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6000000238418579,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":38,"referenced_works":["https://openalex.org/W1511875879","https://openalex.org/W1605804472","https://openalex.org/W1966089070","https://openalex.org/W1978234070","https://openalex.org/W1978645044","https://openalex.org/W1994306174","https://openalex.org/W2000293894","https://openalex.org/W2008048828","https://openalex.org/W2030230833","https://openalex.org/W2032518261","https://openalex.org/W2032960059","https://openalex.org/W2041851681","https://openalex.org/W2056636551","https://openalex.org/W2064899320","https://openalex.org/W2073082177","https://openalex.org/W2078198692","https://openalex.org/W2084107255","https://openalex.org/W2096946446","https://openalex.org/W2110448242","https://openalex.org/W2116100905","https://openalex.org/W2120708925","https://openalex.org/W2120966260","https://openalex.org/W2123682012","https://openalex.org/W2133238120","https://openalex.org/W2147647602","https://openalex.org/W2151637991","https://openalex.org/W2152677047","https://openalex.org/W2155757944","https://openalex.org/W2230864361","https://openalex.org/W2316205619","https://openalex.org/W2317330621","https://openalex.org/W2330579332","https://openalex.org/W2345929525","https://openalex.org/W2388024387","https://openalex.org/W2526191216","https://openalex.org/W2587433340","https://openalex.org/W2897016432","https://openalex.org/W3182208082"],"related_works":["https://openalex.org/W2028471916","https://openalex.org/W2547260311","https://openalex.org/W1589114377","https://openalex.org/W2154842468","https://openalex.org/W2536794900","https://openalex.org/W1538400183","https://openalex.org/W2564500233","https://openalex.org/W1995635042","https://openalex.org/W2999493000","https://openalex.org/W2025215636"],"abstract_inverted_index":{"Phasor":[0],"measurement":[1],"units":[2],"(PMUs)":[3],"have":[4],"offered":[5],"significant":[6],"advancements":[7],"in":[8,22,50,81,120],"power":[9],"system":[10,118],"operation":[11],"and":[12,98,108,136,157,195,198,215],"control.":[13],"Despite":[14],"these":[15],"advantages,":[16],"the":[17,33,41,56,59,82,89,106,109,113,121,133,137,143,146,154,158,162,168,202,210],"industry":[18],"has":[19],"been":[20],"slow":[21,27],"adopting":[23],"PMU":[24,43,114],"technology.":[25],"This":[26,76,188],"adoption":[28],"is":[29,53,129,151,165,207],"partially":[30],"due":[31],"to":[32,72,111,193],"high":[34,63],"cost":[35,64,107,139,148,200],"of":[36,61,78,84,91,123,140,149,201],"installing":[37],"PMUs,":[38],"which":[39,112,160],"motivates":[40],"optimal":[42],"placement":[44],"(OPP)":[45],"problem.":[46],"The":[47,100,171,204],"work":[48],"presented":[49],"this":[51],"paper":[52],"motivated":[54],"by":[55,69],"idea":[57],"that":[58],"value":[60],"a":[62,178,184],"asset":[65],"can":[66,174],"be":[67,175],"increased":[68],"deploying":[70,79],"it":[71],"improve":[73],"network":[74,124,134],"fault-tolerance.":[75],"strategy":[77],"PMUs":[80,150],"proximity":[83],"higher":[85],"probability":[86],"contingencies":[87],"increases":[88],"likelihood":[90],"more":[92],"effective":[93],"remedial":[94],"actions,":[95],"both":[96,105],"preventive":[97],"corrective.":[99],"proposed":[101,144,172,205],"OPP":[102],"therefore":[103],"considers":[104],"extent":[110],"placements":[115],"will":[116],"benefit":[117],"observability":[119],"presence":[122],"vulnerabilities.":[125],"A":[126],"bi-level":[127],"framework":[128],"used":[130,176],"for":[131],"optimizing":[132],"vulnerability":[135,163],"installation":[138,147,180,186,199],"PMUs.":[141,203],"In":[142],"framework,":[145],"treated":[152,166],"as":[153,167,177,183],"primary":[155],"objective,":[156],"observability,":[159],"incorporates":[161],"analysis,":[164],"secondary":[169],"objective.":[170],"approach":[173,189,206],"multistage":[179],"process":[181],"or":[182],"single-stage":[185],"process.":[187],"uses":[190],"evolutionary":[191],"algorithms":[192],"optimize":[194],"prioritize":[196],"locations":[197],"tested":[208],"on":[209],"IEEE":[211,213,216],"14-bus,":[212],"30-bus,":[214],"reliability":[217],"test":[218],"system.":[219]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
